100 50 500 200 100 400 300 0 Maximum speed [mm/s] Cylinder stroke [mm] Example) Load limit at rod end when the air cylinder 50 is actuated at 300 mm/s.
Long Stroke Stroke range (mm) Y X Z Bore size (mm) 12 50, 75, 100 32 7.5 7.5 16 50, 75, 100 32 7.5 7.5 20 75, 100, 125, 150, 175, 200 41 9 9 25 75, 100, 125, 150, 175, 200, 250, 300 44 11 11 8-27-8 9 Platform Cylinder Series CXT Dimensions: 32, 40 (N) X + Stroke S + Stroke H 4-M8 x 1.25 4-8.7 through, counterbore 14 depth 8 HP Depth 12 HG 12 Back side 4-M10 x 1.5 depth 15 (N) T PA T MX d
Built-in magnet for auto-switches CE1 CE2 Maximum Driving Speed of Cylinders ML2B 1000 1000 900 900 C J G5-S Load factor: 10% Load factor: 50% 800 800 Cylinder speed (mm/s) Cylinder speed (mm/s) 700 700 600 600 CV 500 500 400 400 MVGQ 300 300 200 200 CC 100 100 0 0 12 16 20 25 32 40 50 63 80 100 RB SYJ3000 VZ3000 VZ5000 VF3000 Bore size (mm) J Series Variations DDetailed specifications
Stainless Steel Cylinder Se ries CG5-S 20, 25, 32, 40, 50, 63, 80, 100 How to Order X165US TN CG5 L N 25 S R 100 Without Auto Switch X165US TN CDG5 L N 25 S 100 G5BAL R With Auto Switch Inch rod thread (Only available with "TN" port option. Currently only available on the 20 to 63mm bore sizes.)
RS Q G RS H A RZQ Weight MI W S Auto Switch Internal Circuit D-F7NV (g) CEP1 D-F7NV D-F7PV D-F7BV Auto switch model DC (+) Brown CE1 11 13 13 0.5 Lead wire length (m) 50 57 57 3 Main circuit of switch CE2 OUT Black 81 92 92 5 ML2B DC () Blue Dimensions C J G5-S 3.5 mounting hole D-F7PV CV Indicator light DC (+) Brown MVGQ Main circuit of switch Main circuit of switch CC OUT Black RB DC ()
Output deviation factor (% F .S.) 0.6 0.5 0.4 Return 0.2 0 0 0.2 0.4 0.5 Out 0.6 0.8 0 25 50 75 1 1 2 3 4 1 5 100 Input signal (%F .S.)
C S C S C S C 0.016 0.043 MHZ2-10 K 7 12f8 52.8 11 15 Applicable tubing End boss assembly MHZ2-16 K 0.016 0.043 10 16f8 58.7 15 20 MHZ2-20 K 0.020 0.053 D2 12 20f8 70.5 19 22 0.020 0.053 MHZ2-25 K 15 25f8 82.9 24 25 D1 MHZ Other dimensions and specifications correspond to the standard type.
C S C S C S C 0.016 0.043 MHZ2-10 K 7 12f8 52.8 11 15 Applicable tubing End boss assembly MHZ2-16 K 0.016 0.043 10 16f8 58.7 15 20 MHZ2-20 K 0.020 0.053 D2 12 20f8 70.5 19 22 0.020 0.053 MHZ2-25 K 15 25f8 82.9 24 25 D1 MHZ Other dimensions and specifications correspond to the standard type.
37 38.5 43 2.5 0 0 6 5 5.5 7 8 36 40 45 53 6 7 8 11 54 68 86 104 26 42 54 64 5 to 300 5 to 300 5 to 300 5 to 300 MLUB25 MLUB32 MLUB40 MLUB50 Rc, NPT, 1/8 Rc, NPT, 1/8 M8 x 1.25 depth 13 M8 x 1.25 depth 11 Rc, NPT, 1/8 M10 x 1.5 depth 14.5 M10 x 1.5 depth 15 KA H2 K MM MM1 NA NB NC ND NE NG NH NH1 NI NJ NS NY P S ZZ ZZ1 NF Model 10 12 14 18 M10 x 1.25 M12 x 1.25 M14 x 1.5 M18 x 1.5 M6 x 1
Without lead wire: (with connector and 2 of sockets only) SY100-30-A Rated voltage Lead wire length 5 6 V S R 1 2 24 VDC 12 VDC 6 VDC 5 VDC 3 VDC 100 VAC 50/60 Hz 200 VAC 50/60 Hz 110 VAC 50/60 Hz [115 VAC 50/60 Hz] Nil 6 10 15 20 25 30 50 300 mm 600 mm 1000 mm 1500 mm 2000 mm 2500 mm 3000 mm 5000 mm Electrical entry G H L LN LO M MN MO W0 Grommet, 300 mm lead wire Grommet, 600 mm lead wire
(CO2) [mg/L] 4.0 or less v Reference item 5 s 2 s 1 s Min. 0.5 s 0.2 s 0.1 s *1 In the case of [Mcm], it will be 0.003 to 0.01.
44 11 11 3.8-8 Platform Cylinder Series CXT 32, 40 (N) S+Stroke X+Stroke H 4-M8 X 1.25 4-8.7 Through, Counter bore 14 Depth 8 HP Depth 12 HG 12 Back side 4-M10 X 1.5 Depth 15 (N) T PA T CL d d MLGC RW RW CNA M20 X 1.5 CB QW PW GP PB W E CV/MVG Y Z CXW 2-Rc(PT)1/8 CXS CXT G G 2-RB2015 (Option) 2 HT F MX A L HN (MAX.)
After the machine has stopped, make sure to turn off the breaker of the users equipment (on the upstream side). 2 h 1 h 30 min 20 min 14 min 10 min 6 min 4 min 2 min 1 min Operating time 30 s 20 s Max. 10 s 5 s 2 s Min. 1 s 0.5 s 0.2 s 0.1 s 0.05 s 0.02 s 0.01 s 100 135 200 300 400 500 600 700 1000 1500 2000 3000 4000 Current (% for chiller main breaker volume) 341 HRL Series Specific Product
A 3.2 7.2 12 19.1 26.2 19.1 30.6 29.2 27.5 26.1 13.3 9 (9) AS221F-01-04(S)A 4 8.2 AS221F-01-06(S)A 6 10.4 10 (9) AS221F-01-08(S)A 8 13.2 22.4 29.5 14.2 11 (10) AS221F-01-10(S)A 10 15.9 25.3 32.4 15.6 12 (11) AS221F-02-23(S)A 3.2 1/8 13 (12.7) 7.2 20.9 30.2 (30.3) 22.6 36.6 35 31.1 29.5 13.3 18 (19) AS221F-02-04(S)A 4 8.2 AS221F-02-06(S)A 6 10.4 23.4 32.7 (32.8) AS221F-02-08(S)A 8 13.2 23.9
Example using a 20[mm] Lead Actuator with target travel speed of 500[mm/sec] Rotations per second Travel distance per second Travel distance per rotation Rotation Speed (rpm) = {Speed (mm/s) Lead (mm) }60 (S) = {500 (mm/s) 20 (mm) }60 (s) =1500 (rpm) The rotation speed must be a value between 0 and the allowable actuator speed. The actuator will not operate if set to 0.
Configuration One thermo-chiller for one master. 2 2 R D R D 3 3 S D S D 5 5 S G S G Master This product Do not connect any wire to other PIN numbers. Fig. 3-15 Connection of RS-232C HRS Series 3.3Installation 3-27 HRX-OM-S004 Chapter 3 Transport and Setting Up 3.4 Piping Piping port size Connect piping firmly.
kit 16 stations 16 NKE Corp.: Uni-wire H System 1 to 8 stations SUNX Corp.: S-LINK System (16 output points) 8 SUNX Corp.: S-LINK System (8 output points) 1 to 4 stations 8 stations D side DeviceNet, CompoBus/D (OMRON Corp.) 16 16 stations 1 to 8 stations OMRON Corp.: CompoBus/S System (16 output points) OMRON Corp.: CompoBus/S System (8 output points) 8 8 stations 1 to 4 stations Mitsubishi
Data 10-7-13 14 Rotary Clamp Cylinder: Heavy Duty Type Series MK2 20, 25, 32, 40, 50, 63 How to Order MK2 B S F9BW 20 10 R F Number of auto switches Nil S 2 pcs. 1 pc.