(Coil temperature: 20C, at rated voltage, without surge suppressor) Note 2) Impact resistance: No malfunction occurred when it is tested with a drop tester in the axial direction and at the right angles to the main valve and armature in both energized and de-energized states every once for each condition.
capacity (cm3) 55 135 7 135 25 135 135 Recommended lubricant Class 1 turbine oil (ISO VG32) 5 to 60C (with no freezing) Ambient and fluid temperature Bowl material Polycarbonate Bowl guard Standard Option Weight (kg) 0.47 0.24 1.13 0.07 0.52 1.06 0.20 Notes 1) The flow rate is 5 drips/min under the following conditions: Inlet pressure of 0.5MPa; Class 1 turbine oil (ISO VG32); Temperature at 20C
18 Rc3/8 17 16 (kg) White1 (Munsell 10Y8/0.5) Coating color Note1)The data for l/min (ANR) is under the conditions of 20C, atmospheric pressure of 1 atm. and relative humidity of 65%.
NO OFF n-2 n-1 Real-time flow rate Flow rate conversion Normal condition: 0C, 101.3 kPa, dry air Standard condition: 20C, 101.3 kPa, 65%RH (ANR) Switchable between these conditions.
Solenoid Specifications Rated coil voltage Allowable voltage fluctuation Power consumption Surge voltage suppressor Indicator light 24VDC 10% of rated voltage 0.65W Diode LED Response Time Note) Based on JISB8375-1981 dynamic performance test (with coil temperature of 20C and at rated voltage).
Standard condition: Flow rate converted to a volume at 20C and 1 atm (atmosphere) Normal condition: Flow rate converted to a volume at 0C and 1 atm (atmosphere) * Also, the increase or decrease of the flow and temperature will not change the on/off status of the output while the forced output function is activated.
5 to 40C, Humidity: 30 to 70%RHClear water, Deionized water, Aqueous solution of 15% ethylene glycol5 to 359.0/9.5 (at 20C)??1.00.29/0.33 (at 37/49 l/min, total lifting height 25/25 m)37/4940Rc 3/4Stainless steel, Brass, PVC, Nylon 12, Polyurethane, Copper brazing (Heat exchanger)????
5 to 40C, Humidity: 30 to 70%RHClear water, Deionized water, Aqueous solution of 15% ethylene glycol5 to 359.0/9.5 (at 20C)??1.00.29/0.33 (at 37/49 l/min, total lifting height 25/25 m)37/4940Rc 3/4Stainless steel, Brass, PVC, Nylon 12, Polyurethane, Copper brazing (Heat exchanger)????
5 to 40C, Humidity: 30 to 70%RHClear water, Deionized water, Aqueous solution of 15% ethylene glycol5 to 350.9/1.1 (at 20C)??1.0 (Refrigerator ON/OFF control), ?0.5 (Proportional valve PID control)0.14/0.19 (at 8/10 l/min, total lifting height 8/9 m)8/1010Rc 1/2Stainless steel, Brass, PE, PVC, PPE, Copper brazing (Heat exchanger)????
5 to 40C, Humidity: 30 to 70%RHClear water, Deionized water, Aqueous solution of 15% ethylene glycol5 to 354.5/4.8 (at 20C)??1.0 (Refrigerator ON/OFF control), ?0.5 (Proportional valve PID control)0.2/0.26 (at 24/32 l/min, total lifting height 14/15 m)24/3220Rc 1/2Stainless steel, PE, PVC, Brass, Copper brazing (Heat exchanger)????
5 to 40C, Humidity: 30 to 70%RHClear water, Deionized water, Aqueous solution of 15% ethylene glycol5 to 3513.0/14.5 (at 20C)??1.00.28/0.31 (at 42/53 l/min, total lifting height 25/25 m)42/5360Rc 3/4Stainless steel, Brass, PVC, Nylon 12, Polyurethane, Copper brazing (Heat exchanger)????
Please contact us for the latest version.sales@ocaire.com, THERMO CHILLER *LQA, OTHERS, HRG - INDUSTRIAL CHILLER, 22, HRG - NO SIZE RATING, 165.34669 lb, ModelCooling methodRefrigerantControl methodAmbient temperature/humidity Note 1)Circulating fluid systemFacility water systemElectrical systemWeight Note 10) kgCirculating fluid
5 to 40C, Humidity: 30 to 70%RHClear water, Deionized water, Aqueous solution of 15% ethylene glycol5 to 3513.0/14.5 (at 20C)??1.00.28/0.31 (at 42/53 l/min, total lifting height 25/25 m)42/5360Rc 3/4Stainless steel, Brass, PVC, Nylon 12, Polyurethane, Copper brazing (Heat exchanger)????
5 to 40C, Humidity: 30 to 70%RHClear water, Deionized water, Aqueous solution of 15% ethylene glycol5 to 359.0/9.5 (at 20C)??1.00.29/0.33 (at 37/49 l/min, total lifting height 25/25 m)37/4940Rc 3/4Stainless steel, Brass, PVC, Nylon 12, Polyurethane, Copper brazing (Heat exchanger)????
Bore Size: 8mm, Symmetric Type: L (Symmetric), Stroke: 20mm, Adjuster: C (Both Side Adjusters/Metal Stoppers)
Bore Size: 8mm, Symmetric Type: Symmetric, Stroke: 20mm, Adjuster: Both Side Adjusters/Metal Stoppers, Function: -, Auto Switch: -, Lead Wire or Prewired Connector: -, Number: -
Bore Size: 8mm, Symmetric Type: L (Symmetric), Stroke: 20mm, Adjuster: C (Both Side Adjusters/Metal Stoppers), Function: Standard, Auto Switch: M9B--Solid State, Gen. Purpose, 2 Wire, Horizontal, 0.5M, Lead Wire or Prewired Connector: L (3m)
Bore Size: 8mm, Symmetric Type: L (Symmetric), Stroke: 20mm, Adjuster: C (Both Side Adjusters/Metal Stoppers), Function: Standard, Auto Switch: M9BW--Solid State, 2-color Indication, 2 Wire, Horizontal, Lead Wire or Prewired Connector: L (3m)
Bore Size: 8mm, Symmetric Type: L (Symmetric), Stroke: 20mm, Adjuster: C (Both Side Adjusters/Metal Stoppers), Function: Standard, Auto Switch: M9N--Solid State, Gen. Purpose, 3 Wire NPN, Horizontal, 0.5M, Lead Wire or Prewired Connector: L (3m)
Bore Size: 8mm, Symmetric Type: L (Symmetric), Stroke: 20mm, Adjuster: C (Both Side Adjusters/Metal Stoppers), Function: Standard, Auto Switch: M9B--Solid State, Gen. Purpose, 2 Wire, Horizontal, 0.5M, Lead Wire or Prewired Connector: L (3m), Number: S (1 pc.)