Body Size: 30, Pipe Thread: N (NPT), Port Size: 03 (3/8), Mounting: w/o Mounting Option, Nominal Filtration Rating: 80 (80µ), Water Removal Type: T (Large Flow Type), Semi-standard: Z (Name Plate And Caution Plate For Bowl In Imperial Unit (PSI, °F))
(Refer to pages 15-6-3 to 15-6-5 for details.) 15-13-1
Speed Controller/In-line Type AS2000-N02-X800/AS3000-N03-X800/AS4000-N04-X800 P .G. information Point to Group Specialized Product Flow Characteristics AS3000-N03-X800 AS4000-N04-X800 AS2000-N02-X800 300 800 Flow rate L/min (ANR) Flow rate L/min (ANR) Flow rate L/min (ANR) 1500 250 600 200 1000 150 400 100 500 200 50 0 0 1 2 3 4 5 6 7 9 8 10 0 0 1 2 3 4 5 6 7 9 8 0 0 1 2 3 4 5 6 7 8 Number
Piston assembly Valve Valve spring No. 4 5 6 1348104A 1348105 1348109 SUP OUT 2 ARX Series Specialty Regulators Regulator for 290 psi (2 MPa) ARX20, 21 Dimensions Panel cutout dimensions 1.02 (26) R .1 (2.5) SUP OUT SMC K C O P A A L U S H .5 (12) 1.61, 2.13 [41 (K40)], [49 (K50)] 2.13 (54) .98 (25) 1.6 (max. thickness 4.5) 1.73 (44) .21 (5.4) 3.13 (79.5) (when regulating pressure = 3.23
-PS IDG5-N02-PS IDG10-N03-P IDG20-N03-P IDG30-N03-P IDG50-N03-P IDG60-N04-P IDG75-N04-P IDG1-N02-P The membrane air dryer uses hollow fibers composed of a macro molecular membrane through which moisture passes easily, but is difficult for air (oxygen and nitrogen) to pass through.
Series AF modular style air filter is a cost effective, clean looking solution to your filtration needs. Its' modular design allows connection with other SMC air preparation equipment. The series is available in six size options with a wide range of accessories.Modular air filter , Prevents contamination , Lighter weight than old style modular AF , Thickness reduction of resin case provides
[V] A B C 0-101 kPa 0 -101 kPa 10.1 kPa -100100 kPa -100 kPa 100 kPa 01 MPa 0 1 MPa -0.1 MPa 0500 kPa 0 500 kPa -50 kPa -13No.PS-OMG0005CN-E PSE5601 PSE56N01 02 N02 PSE56-C01 A B PSE56-01 8.2 R1/8 PSE56-02 12 R1/4 PSE56-N01 9.2 NPT1/8 PSE56-N02 12.2 NPT1/4 PSE56-A2 PSE56-C01 Rc1/8 PSE56-A2 15.5 URJ1/4 PSE56-B2 9.5 TSJ1/4 PSE56-B2 ZS-31-X D E F G H I ZS-31-X188 20 9 R1/8 R1/8 14 1.5
This is a legacy product, and replaced byZSE20CF-T-N02-W ZSE40/50/60 VACUUM SWITCH. SWITCH ASSEMBLY. VACUUM SERIES. ZSE40/50/60 1/4 PORTED. .19841 lb. KD.
Setting Type: 1 (Adjustable Type, Handle), Set Pressure: 2 (0.02 to 0.2MPa), Port Size: N02 (1/4 NPT), Accessory: G (Pressure Gauge), Suffix: T [High Temperature (-10 to 100°C)]
Pressure Range: ISE70G (0 to 1 MPa), Piping: N02 (NPT 1/4), Orifice: T (Orifice shipped with the Product), Unit Specification: Unit Selection Function, Switches w/Unit Selection not Permitted for Use in Japan, Lead Wire: None, Bracket: None, Operation Manual/Calibration Certificate: Y (None)
Rated Pressure Range: H (-0.1 to 2 MPa), Output Specification: T (PNP Open Collector 2 Outputs + Analog Voltage Output), Unit Specification: P (Unit Selection Function, Initial value psi), Piping Specification: N02 [NPT1/4, (M5, Female Threaded)]
Pressure Range: ISE70 (0 to 1 MPa), Piping: N02 (NPT 1/4), Output Specification: L2 (I/O Link: Switch Output 1 + Switch Output 2 [Switch Output: NPN or PNP Switching Type]), Unit Specification: Unit Selection Function, Switches w/Unit Selection not Permitted for Use in Japan, Lead Wire: None, Bracket: A (Bracket A, Interchangeable with ISE70), Operation Manual/Calibration Certificate: T (
Pressure Range: ISE70 (0 to 1 MPa), Piping: N02 (NPT 1/4), Output Specification: L2 (I/O Link: Switch Output 1 + Switch Output 2 [Switch Output: NPN or PNP Switching Type]), Unit Specification: Unit Selection Function, Switches w/Unit Selection not Permitted for Use in Japan, Lead Wire: None, Bracket: None, Operation Manual/Calibration Certificate: T (Calibration Certificate)
Pressure Range: ISE77G (0 to 10 MPa), Piping: N02 (NPT 1/4), Orifice: T (Orifice shipped with the Product)
Pressure Range: ISE70G (0 to 1 MPa), Piping: N02 (NPT 1/4), Orifice: None, Unit Specification: Unit Selection Function, Switches w/Unit Selection not Permitted for Use in Japan, Lead Wire: None, Bracket: None, Operation Manual/Calibration Certificate: T (Calibration Certificate)
Pressure Range: ISE77G (0 to 10 MPa), Piping: N02 (NPT 1/4), Orifice: T (Orifice shipped with the Product), Unit Specification: Unit Selection Function, Switches w/Unit Selection not Permitted for Use in Japan, Lead Wire: None, Bracket: A (Bracket A, Interchangeable with ISE75[H])
Flow Rate Range: 11 [2 to 100 (50 for CO2) â„“/min], Flow Adjustment Valve: None, Port Size: N02 (NPT1/4), Piping Entry Direction: Straight, Output Specification: 2 [Analog Output (4 to 20 mA)], Instruction Manual: With Instruction Manual, Calibration Certificate: A (w/Calibration Certificate), Connector: W [Lead Wire w/Connector (2m) + Rubber Cover], Option: T (Panel Mount Adapter for w/
This is a legacy product, and replaced byY410-N02-A, T-TYPE SPACER, AIRLINE EQUIPMENT, AC MASS PRO, 22, AC MASS PRO NO SIZE RATING, .14960 lb
This is a legacy product, and replaced byY21-N02-A, T-PORT ADAPTOR 1/4 NPT, AIRLINE EQUIPMENT, AC FRL COMBO, 22, AC NO SIZE RATING ACCESSORY, .04400 lb
Model: T (Male Branch Tee, Union Tee, Different Dia. Tee), Applicable Tube O.D.: 07 (1/4"), Port Size/Applicable Tube: N02 (1/4" Thread)