Series SZ3000 is a 5 port solenoid valve, body ported type with a cassette style manifold. The SZ series offers high reliability and long life of 50 million cycles or more. The connector entry direction can be changed from top to side with a simple operation. Low power consumption and a fast response time of 10ms are obtained with a unique pilot valve construction.
Fluid: Air, Operating pressure range: up to 0.7Mpa, Valve effective area mm² (Cv factor): P to A/B 3.0 to 3.7 (0.17 to 0.21) A/B to R 3.2 to 3.9 (0.18 to 0.22), Coil rated voltage: 24, 12, 6, 5, 3DC, Response time: minimum 10 or less 4/5 PORT SOLENOID VALVE. VALVE 2POS/SGL, CASSETTE TYPE. 74 lb. G92.
Fluid: Air, Operating pressure range: up to 0.7Mpa, Valve effective area mm² (Cv factor): P to A/B 3.0 to 3.7 (0.17 to 0.21) A/B to R 3.2 to 3.9 (0.18 to 0.22), Coil rated voltage: 24, 12, 6, 5, 3DC, Response time: minimum 10 or less 4/5 PORT SOLENOID VALVE. VALVE, NON PLUG IN. 78 lb.
Size: 1/2, Thread: NPT, Port Size: 1/2-AV4000 Only, Option: None, Voltage: 110~120VAC, Lead Wire: Type Y DIN Terminal Without Connector, Surge Suppressor: -, Manual Override: -, Flow Direction: -, Q: -
Size: 1/2, Thread: Rc, Port Size: 1/2-AV4000 Only, Option: None, Voltage: 24VDC, Lead Wire: Type Y DIN Terminal Without Connector, Surge Suppressor: -, Manual Override: -, Flow Direction: -, Q: -
Size: 1/2, Thread: NPT, Port Size: 1/2-AV4000 Only, Option: Pressure Gauge, Voltage: 110~120VAC, Lead Wire: Type Y DIN Terminal, Surge Suppressor: Light+Surge Suppressor, Manual Override: Non-locking Push Style (Flush), Flow Direction: Right to Left, Q: -
Size: 1/2, Thread: Rc, Port Size: 1/2-AV4000 Only, Option: None, Voltage: 24VDC, Lead Wire: DIN Terminal w/o Connector, Surge Suppressor: -, Manual Override: -, Flow Direction: -, Q: -
Size: 1/2, Thread: Rc, Port Size: 1/2-AV4000 Only, Option: None, Voltage: 24VDC, Lead Wire: DIN Terminal w/o Connector, Surge Suppressor: Light+Surge Suppressor, Manual Override: Locking (Lever Type), Flow Direction: Right to Left, Q: -
Size: 1/2, Thread: Rc, Port Size: 1/2-AV4000 Only, Option: None, Voltage: 24VDC, Lead Wire: Type Y DIN Terminal Without Connector, Surge Suppressor: None, Manual Override: Locking (Slotted), Flow Direction: -, Q: -
Size: 1/2, Thread: G, Port Size: 1/2-AV4000 Only, Option: None, Voltage: 24VDC, Lead Wire: DIN Terminal w/o Connector, Surge Suppressor: -, Manual Override: -, Flow Direction: -, Q: -
Size: 1/2, Thread: G, Port Size: 1/2-AV4000 Only, Option: None, Voltage: 24VDC, Lead Wire: DIN Terminal, Surge Suppressor: None, Manual Override: Non-locking Push Style (Flush), Flow Direction: Right to Left, Q: -
Size: 1/2, Thread: G, Port Size: 1/2-AV4000 Only, Option: None, Voltage: 12VDC, Lead Wire: DIN Terminal w/o Connector, Surge Suppressor: -, Manual Override: -, Flow Direction: -, Q: -
Size: 1/2, Thread: NPT, Port Size: 1/2-AV4000 Only, Option: None, Voltage: 110~120VAC, Lead Wire: DIN Terminal, Surge Suppressor: None, Manual Override: Non-locking Push Style (Flush), Flow Direction: Right to Left, Q: -
Size: 1/2, Thread: NPT, Port Size: 1/2-AV4000 Only, Option: None, Voltage: 110~120VAC, Lead Wire: Type Y DIN Terminal, Surge Suppressor: None, Manual Override: Non-locking Push Style (Flush), Flow Direction: Right to Left, Q: -
Size: 1/2, Thread: NPT, Port Size: 1/2-AV4000 Only, Option: None, Voltage: 24VDC, Lead Wire: DIN Terminal, Surge Suppressor: None, Manual Override: Locking (Slotted), Flow Direction: Right to Left, Q: -
Size: 1/2, Thread: NPT, Port Size: 1/2-AV4000 Only, Option: None, Voltage: 24VDC, Lead Wire: DIN Terminal w/o Connector, Surge Suppressor: Light+Surge Suppressor, Manual Override: Locking (Slotted), Flow Direction: -, Q: -
Size: 1/2, Thread: NPT, Port Size: 1/2-AV4000 Only, Option: None, Voltage: 24VDC, Lead Wire: DIN Terminal w/o Connector, Surge Suppressor: Light+Surge Suppressor, Manual Override: Locking (Lever Type), Flow Direction: Right to Left, Q: -
Size: 1/2, Thread: NPT, Port Size: 1/2-AV4000 Only, Option: None, Voltage: 24VDC, Lead Wire: Grommet, Surge Suppressor: None, Manual Override: Locking (Lever Type), Flow Direction: Right to Left, Q: -
Size: 1/2, Thread: NPT, Port Size: 1/2-AV4000 Only, Option: Pressure Gauge, Voltage: 110~120VAC, Lead Wire: DIN Terminal, Surge Suppressor: None, Manual Override: Non-locking Push Style (Flush), Flow Direction: Right to Left, Q: -
Size: 1/2, Thread: NPT, Port Size: 1/2-AV4000 Only, Option: Pressure Gauge, Voltage: 24VDC, Lead Wire: DIN Terminal, Surge Suppressor: None, Manual Override: Locking (Slotted), Flow Direction: Right to Left, Q: -