B Released SET Work 1 Work 2 Work n Atmosphere Max. A: Maximum pressure value when work piece is adsorbed. A B 4 ON = A A B 4 SET OFF = B + Min. B: Minimum pressure value when work piece is not adsorbed. OUT1 auto preset For adsorption verification: In this mode, repeat the adsorption and release of the work piece for a few times. The optimum values will be set automatically.
NVV5Z5-4 2-( 05 ) 1 -r87T) Y -r.Stationsa asize ot A, B port E-?
Single clevis MUC25SMU25, #5 (#1+#5+#11) MUC32SMU32, #5 (#1+#5+#11) MUC40SMU40, #5 (#1+#5+#11) MUC50SMU50, #5 (#1+#5+#11) MUC63SMU63, #5 (#1+#5+#11) 2.4-5 Plate Cylinder/Double Acting Double Rod Series MUW 20, 32, 40, 50, 63 How to Order Standard MUW B 25 30 D M MDUW B 25 30 D M A73 S With auto switch Built-in magnet Number of auto switches 2 1 n Double rod S n Mounting B L F Basic Foot
B Released SET Work 1 Work 2 Work n Atmosphere Max. A: Maximum pressure value when workpiece is adsorbed. A B 4 ON = A A B 4 SET OFF = B + Min. B: Minimum pressure value when workpiece is not adsorbed. OUT1 auto preset For adsorption verification: In this mode, repeat the adsorption and release of the workpiece for a few times. The optimum values will be set automatically.
Pin description A B Output specification 1 DC(+) Output for display unit only 42 62 2 NC/Analog output 3 DC() Output for display unit + Analog output 52 72 4 OUT Flow direction 22 Series PF2W Dimensions: Remote Type Sensor Unit for Water PF2W511-(N)B 148 32 80 70 58 46 45 36 2-Port size 45 2 4-5.5 (44.2) A (mm) A B Output specification Output for display unit only 63 77 Output for display
For air brake applications, (using SAE J8zl4 Type A and B Nylon tubing) sizes 5/32" and above meet D.O.T. FMVSS 571.106, S.A.E. J1 131 andior the proposed S.A.E. J2494 air brake performance specifications. The 1/8" SMC Encapsulated Cartridges are not D.O.T./S.A.E. rated and are designed f,cr use in pressure protected air accessory lines that are isolated from the air brake svstem.
B Released SET Work 1 Work 2 Work n Atmosphere Max. A: Maximum pressure value when work piece is adsorbed. A B 4 ON = A A B 4 SET OFF = B + Min. B: Minimum pressure value when work piece is not adsorbed. OUT1 auto preset For adsorption verification: In this mode, repeat the adsorption and release of the work piece for a few times. The optimum values will be set automatically.
4 2 5 A 10 x 8 3/4" x 5/8" 5 1 5 B 19 x 16 1/2" x 3/8" 5 2 6 A 12 x 10 1" x 7/8" SMC 6 1 6 B 25 x 22 3/4" x 5/8" 6 2 19 x 16 : Basic size : With reducer Note) Please select an isometric fitting with the same size as the fitting at the flow sensor.
PF2A5--2 (With voltage output type) PF2A511, 521, 551 B Wiring 116 23 1.6 76.2 Brown (1) DC(+) Main circuit Black (4) OUT (Output for display unit) White (2) NC/Analog output 54 44 34 Blue (3) DC() Use this sensor by connecting it to a P/A remote type display unit Series PF2A2/3. 4-4.5 2-Port size 30 40 50 Connector pin numbers 2 1 (44.2) A 4 3 (mm) A B Output specification Pin no.
Note 2) JIS B 8370: Pneumatic system axiom. 1 The compatibility of pneumatic equipment is the responsibility of the person who designs the pneumatic system or decides its specifications.
H B H Material: SUS304 Material: SUS304 Material: SUS304 Part no.
Description Panel mounting adapter A, B ZS-22-E Front protective cover + Panel mounting adapter ZS-26-B ZS-26-C With mounting bracket Panel mounting adapter With waterproof seal, mounting screw With waterproof seal, mounting screw Panel Front protective cover PF2D30 Mounting screw (M3 x 8 L) (accessory) Panel mounting adapter A Panel mounting adapter Panel mounting adapter B Mounting bracket
Diaphragm Type Pilot Operated 2 Port Solenoid Valve for High Pressure VXH Series [Option] VX2 Valve Specifications VXK Orifice diameter 10 Max. operating pressure: 2.0 MPa Max. operating pressure differential (MPa) Min.operating pressure differential (MPa) Kv Cv converted C[dm /(sbar)] b Cv Water, Oil, Steam Air Flow rate characteristics Orifice dia.
SVHK2 #1 to #15 3.6-3 3.6-3 VHK 1(P): One-touch fitting, 2(A): Male thread SlA VlA SlA VlA Bracket mounting dimension B Model Effective area (mm2) Tube O.D. (mm) Connection thread R(PT) S (Width across flats) Weight (g) Bracket ass'y No.
Insert tube until it clears mountain of barb completely. 1 6 2 3 4 A B 5 3 2 Cover mounting G Cover is mountable on both sides, plug side and socket side.
2 VX3 ) VXA How to Order VN VXH2230 02 1 G LVC LVA Bracket Nil B 3 -B JIS Symbol LVH LVD Valve/Body 0 3 ' +0 Electrical option Nil 3 LVQ S ( L LQ Z + ( Port size 6 ( 2 (-' LVN 02 03 04 6 +" 6 &+$ 6 +! TI/ TIL Electrical entry G 8 PA Rated voltage C ) 2 ! >) +# = 1 >) +# = D 543 PAX T ) 3 >) +# = 6 ( 4 !! >) +# = PB 7 !"
Body Size: 20, Thread: Rc: Size 20, 25, 30, 40; M5: Size 10, Port Size: 01 (1/8), Option: Standard, Semi-Standard 1: C (Bowl Guard), Semi-Standard 2: R (Flow Direction: Right to Left)
Body Size: 20, Back Flow: w/o Backflow, Thread: Rc, Port Size: 02 (1/4), Mounting Option: B (With Bracket), Float Type Auto Drain Option: Without Auto Drain, Pressure Gauge/Switch Option: Without Pressure Gauge, Set Pressure: 0.05 to 0.85 MPa Setting, Bowl: Polycarbonate Bowl, Bowl Guard: C (w/Bowl Guard), Drain Port: w/Drain Cock, Exhaust Mechanism: Relieving Type, Flow Direction: R (Flow
Body Size: 20, Back Flow: w/o Backflow, Thread: Rc, Port Size: 02 (1/4), Mounting Option: Without Mounting, Float Type Auto Drain Option: Without Auto Drain, Pressure Gauge/Switch Option: G (Round type pressure gauge with limit indicator), Set Pressure: 0.05 to 0.85 MPa Setting, Bowl: Polycarbonate Bowl, Bowl Guard: C (w/Bowl Guard), Drain Port: w/Drain Cock, Exhaust Mechanism: Relieving
Body Size: 20, Back Flow: w/o Backflow, Thread: Rc, Port Size: 02 (1/4), Mounting Option: Without Mounting, Float Type Auto Drain Option: C (N.C. (Normally closed) Drain port is closed when pressure is not applied), Pressure Gauge/Switch Option: E (Square embedded type pressure gauge with limit indicator), Set Pressure: 0.05 to 0.85 MPa Setting, Bowl: Polycarbonate Bowl, Bowl Guard: C (w/