Magnet: D (Built-in), Mounting: B (Basic Style), Style: Aluminum Tube, Bore Size: 100mm, Thread: Rc, Stroke: 1000mm, Option: w/o Rod Boot, Cushion: Both Sides (Air-hydro has No Cushion), Lock Operation: D (Spring/Air Pressure Lock), Auto Switch: M9P--Solid State, Gen. Purpose, 3 Wire PNP, Horizontal, Lead Wire or Prewied Connector: SAPC (0.5m Cord Length, M8-3 Pin Connector)
Cylinder (Tube) Inner Diameter(φ): 100, Stroke(mm): 25, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Single Rods, Main Body Shape: Standard, Additional Function: With fall prevention function / With Brake / With Intermediate Stop Function, Environment, Applications: Standard, Cushion: With cushions on both sides, Operating Pressure(MPa): 0.08 to 1.0, Specification
Magnet: Built-in, Mounting: Basic Style, Style: Aluminum Tube, Bore Size: 100mm, Thread: Rc, Stroke: 1000mm, Option: w/o Rod Boot, Cushion: Both Sides (Air-hydro has No Cushion), Lock Operation: Spring/Air Pressure Lock, Auto Switch: M9P--Solid State, Gen. Purpose, 3 Wire PNP, Horizontal, Lead Wire or Prewied Connector: 0.5m Cord Length, M8-3 Pin Connector, Number: -
Magnet: Built-in, Mounting: Basic Style, Style: Aluminum Tube, Bore Size: 100mm, Thread: Rc, Stroke: 100mm, Option: w/o Rod Boot, Cushion: Both Sides (Air-hydro has No Cushion), Lock Operation: Spring/Air Pressure Lock, Auto Switch: F5P--Solid State, Gen. Purpose, 3 Wire PNP, Lead Wire or Prewied Connector: 5m, Number: -
Magnet: Built-in, Mounting: Basic Style, Style: Aluminum Tube, Bore Size: 100mm, Thread: Rc, Stroke: 500mm, Option: w/o Rod Boot, Cushion: Both Sides (Air-hydro has No Cushion), Lock Operation: Spring/Air Pressure Lock, Auto Switch: A53--Reed, DC Volt >5<24, LED, Lead Wire or Prewied Connector: -, Number: -
Magnet: Built-in, Mounting: Basic Style, Style: Aluminum Tube, Bore Size: 100mm, Thread: Rc, Stroke: 75mm, Option: w/o Rod Boot, Cushion: Both Sides (Air-hydro has No Cushion), Lock Operation: Spring/Air Pressure Lock, Auto Switch: F5P--Solid State, Gen. Purpose, 3 Wire PNP, Lead Wire or Prewied Connector: 5m, Number: -
Printed in Japan 1st printing September, 2000 D-SMC.L.A. P-80 (YG) This catalog is printed on recycled paper with concern for the global environment.
10 500 700 900 10 700 1,000 Flow rate Q l/min (ANR) How to read the graph The sonic range pressure to generate a flow rate of 500 l/min (ANR) is P1 0.14 MPa for a 6 orifice (VX2 4), and P1 0.3 MPa for a 4.5 orifice (VX23). 3 2 For Saturated Steam [663] (179) Upstream pressure of valve P1 1.0 MPa 1.0 [664] (183) 0.9 0.95 [662] (174) 0.8 0.9 0.85 [661] (170) 0.7 0.8 0.75 Subsonic [660]
U D-A79W D-F7WV D-F7V D-F7BAVL A B A B Proper auto switch mounting positions (mm) D-A7H, D-A80H D-A73C, D-A80C D-F7 D-F7V D-F7W, D-F7WV D-J79 D-J79C, D-J79W D-F7BA D-F9 D-F9V D-F9W D-F9WV D-A7 D-A80 D-A9 D-A9V D-A79W D-F7NTL D-F7F D-F9BAL Bore size (mm) A B A A A A B A A A B B B B B B 20.5 11.5 21 18 25 26 12 9 16 17 20 27 20 27.5 24.5 31.5 26 19 30 29 32.5 20.5 17.5 24.5 23 22 25.5 32
Auto Switch Mounting Height [mm] [mm] Band mounting Rail mounting Auto switch model Auto switch model D-M9l*1 D-M9lV D-M9lW D-M9lWV D-M9lA D-M9lAV D-A9l*2 D-A9lV D-F7l D-J79 D-F7lW D-J79W D-F79F D-F7BA D-A7lH D-A80H D-H7l D-H7lW D-H7BA D-H7NF D-C7l D-C80 D-M9l D-M9lW D-M9lA D-A9l*1 D-M9lV D-M9lWV D-M9lAV D-A9lV*1 D-F7lV D-F7lWV D-F7BAV D-J79C D-A7l D-A80 D-A73C D-A80C *2 D-A79W D-H7C D-C73C
D-A72/D-A73/D-A80 Band Mounting Style . D-A7xH/D-A80H Rail Mounting Style. D-A73C/D-A80C Rail Mounting Style .
D-M9(V)/M9W(V)/M9A(V) D-A9(V) D-B5/B6 D-G5/K5 Hs Hs B A B A D-B7/B8 D-G7/K7 D-C7/C8 D-H7 Hs Hs B A B A Proper Auto Switch Mounting Position (mm) Proper Auto Switch Mounting Height (mm) D-B7/B80 D-B73C D-B80C D-G79/K79 D-K79C D-H7C D-G5NT D-G5/K59 D-G5W D-K59W D-B5/B64 D-B59W D-G5BA D-G59F Auto switch model D-G59F/G5 D-K59 D-G5W D-K59W D-G5NT D-G5BA Auto switch model D-H7 D-H7C D-H7NF D-H7W
8 10 12 7.5 9 4 4 5 15 Data Hs D-A7H/A80H D-A73C/A80C D-F7/J79 D-F7W/J79W D-F7V D-F7WV D-J79C/A72 D-F7BAL D-F79F 5 16 20 25 8 10 12 8 9.5 2 2 3 (mm) C85 Auto Switch Mounting Height D-A7 D-A80 D-A7H/A80H D-F7/J79 D-F7W/J79W D-F7BAL D-F79F D-F7V D-F7WV D-F7BAVL D-C7/C80 D-H7 D-H7W D-H7BAL D-H7NF D-C73C D-C80C D-A73C D-A80C D-H7C D-A79W D-J79C D-H7 D-H7C D-H7W D-H7BAL D-H7NF Bore 3 16 Hs Hs
/C8 D-H7 A B 11.5 8.5 16 Auto switch D-C7/C8, D-H7 D-B5/B6 D-G5/K5 A 12 14.5 B 24.5 Auto switch D-B5/B6, D-G5/K5 D-B7/B8 D-G7/K7 8.5 A 14.5 B 11 Auto switch D-B7/B8, D-G7/K7 Auto Switch Mounting Position D-B7/B8 D-B73C D-B80C D-G7/K7 D-K79C D-B7/B8 D-B73C D-B80C D-G7/K7 D-K79C Auto switch model D-C7/C8 D-C73C D-C80C D-G5 D-K5 D-G5NYL D-B59W D-H7 D-H7C D-H7W D-H79F D-H7BAL Bore size (mm
0 28 1.5 31 CS1 80 2.5 28 6 21.5 14 29.5 9 24.5 6.5 22 2.5 28 5.5 31 100 2.5 28 6 31.5 14 39.5 9 34.5 6.5 32 2.2 28 5.5 31 C76 C85 Auto Switch Mounting Height C95 D-F5, D-J5 D-F5W, D-J59W D-F5BAL, D-F5NTL D-F59F D-A3, D-K39 D-G39 D-A44 D-Z7, D-Z80 D-Y59, Y7P D-Y7W D-A5 D-A6 D-A59W D-Y69, D-Y7PV D-Y7WV D-Y7BAL D-P5DWL Bore size (mm) CP95 Hs Ht Hs Ht Hs Ht Hs Ht Hs Ht Hs Ht Hs Ht Hs Ht NCM
www.stevenengineering.com I 5.18 AIR PREPARATION FILTERS: HIGH EFFICIENCY HIGH FLOW AIR FILTER SERIES (N)AF Port Sizes 1 122Rc, NPT, PF 5m Filter Element High Efficiency Drainage Bowl Guard Standard S Y M B O L S T E C H N I C A L SPECIFICATIONS D I M E N S I O N S A I R F I LT E R M O D E L S (N)AF800/900 D I M E N S I O N S A I R F I LT E R M O D E L S (N)AF811/911 (N)AF800 (N)AF900 112
Auto Switches: Proper Mounting Positions and Mounting Heights for Stroke End Detection D-M9 D-M9W D-M9AL D-A9 D-M9V D-M9WV D-M9AVL D-A9V CHQ CHQ CHK 32 to 100 20 CHN Approx. U CHM 25 CHS CH2 Approx. U B A CHA B A Related Products D-F7 D-F7W D-J79 D-J79W D-A7 D-A7H D-A8 D-A8H D-F7V D-F7WV D-F7BA D-F7BAV D-F7NT D-F79F D-J79C D-A73C D-A80C 32 to 100 DApprox. U B A Approx.
Auto Switch Internal Circuit D-A90(V) Contact protection box OUT () Brown Reed switch Unit: g Weight CD-P11 OUT () Blue CD-P12 D-A90 D-A90V D-A93 D-A93V D-A96 D-A96V Auto switch model Lead wire length: 0.5 m 6 6 6 6 8 8 D-A93(V) Lead wire length: 3 m 30 30 30 30 41 41 LED diode Brown OUT (+) Brown Contact protection box Resistor Unit: mm Dimensions Reed switch Zener diode CD-P11 D-A90/D-A93
Minimum Strokes for Auto Switch Mounting Hydraulic Fluid Compatibility (mm) Hydraulic fluid Compatibility D-A7 D-A80 D-A73C D-A80C D-A7H D-A80H D-A9 D-A9V Standard mineral hydraulic fluid Compatible D-F9BAL D-F7WV D-F9W D-F9WV D-F7W D-J79W D-F7BAVL W/O hydraulic fluids Compatible D-F7V D-J79C D-F9 D-F9V D-F7BAL D-F7NTL D-F79F D-F7 D-J79 D-F7LF D-A79W No. of auto switches O/W hydraulic fluids