C D Can be mounted 2 ways Improves ease of mounting the unit. A B Table running accuracy (mm) The LG1 series provides a stainless steel frame (LG1TH) for customers who required rigidity with an extendable aluminum frame. Refer to page 41 for further details.
D 3 Set the test operation select switch to the Up Position, when performing the test operation mode by using set up software (MR ConfiguratorTM) E 2 F 1 0 (Note) This table indicates the status when the switch is set to "Down".
t V#6500 O.D.268 X I .D.225 X T3 1 pc. O.D.218 X I.D.175 X T3 1 pc. Gasket AL-62S AL63S 3 pcs. AL-31S y JIS B2401G35 5 pcs. O ring JIS B2401G35 1 pc. JIS B2401G35 3 pcs. JIS B2401G35 3 pcs.
After removing the cause of the alarm or warning, the alarm or warning can be deactivated in any of the methods marked in the alarm / warning deactivation column. "6" of the figure, "B" of the alphabet, and "D" are displayed as follows. 6 B D 7.1 Alarms List This section provides list of alarms.
150 E 270 F 823 G 3 H 797 J 620 AMF801 AMF901 445 12B 570 300 520 1093 3 867 AMF800/900/1000 ORIENTATION holes Label Drain Model Connection (Flange) 2B 8B C 2B, 3B, 4B 500 A 330 B 300 D 1070 E 1200 F 1290 G 20 H 720 M16 x l400 Anchor bolt M20 x l500 AMF800 AMF900 400 550 560 745 300 300 1070 1090 1230 1320 1335 1450 24 24 4B, 6B 870 M20 x l500 AMF1000 14-20-48
(34) C D C C IN OUT IN IN OUT OUT E (Element removal dimension) Differential pressure indicator Differential pressure indication switch B DRAIN (mm) d A B C D E F Weight (kg) Model FH100-06 FH100-08 FH100-10 FH100-12 FH100-16 FH100-20 FH100-24 3/4 102 90 35 200 290 2.5 1 104 1 1/4 110 100 45 265 380 4.3 1 1/2 144 150 128 52 299 430 6.8 2 2 1/2 175 200 157 70 387 540 17.5 3 520
Configuration One thermo-chiller for one master. 2 2 R D R D 3 3 S D S D 5 5 S G S G Master This product Do not connect any wire to other PIN numbers. Fig. 3-12 Connection of RS-232C 3.3 Installation HRR Series 3-20 HRX-OM-X071 Chapter 3 Transport and Setting Up 3.4 Piping Piping port size Connect piping firmly.
M plug connector, Without lead wire and light and surge voltage suppressor U side D side Port size (Body ported only) Station1 2 3 4 5 VQD1151-5L M5 thread M5 VQD1000-10A-5 2B 4A 3R 1P 2B 4A VV4QD15-05M5 1.13-8 Series VQD1000 Manifold Option Blank Plate Assembly/Body Ported VVQD1000-10A-2 SY Blank plate assembly includes 2 screws and 1 gasket.
S1, S2: Fixed orifice S3: Variable orifice (adjusted by setting dial) S4: Detection nozzle S1: Fixed orifice S2: Detection nozzle Measures against clogging Measures against clogging D C Number of orifices Orifice area ratio 3 1 68% increase1 By reducing the number of internal orifices from 3 A larger orifice area provides less possibility of to 1, there is less possibility of variations
Converter nominal size Electrical entry of solenoid valve Through the availability of a wide range of series in terms of converter capacity and valve unit flow rate control capa63 100 160 63mm 100mm 160mm G C D Air operated Grommet Conduit DIN terminal bility, speeds as high as 200mm/s (throttle valve) can be achieved with a 80 cylinder.
e f g Nil Reed switch L R Solid state switch S h Nil L R S Operating direction Left Right a b h g d c f e Note) Lead wire length symbols 0.5m .
CM01-8DP4S DDK Ltd. 10 Series PF2A Dimensions PF2A703H, 706H, 712H D E Internal circuits and wiring examples to are terminal numbers.
Cylinder (Tube) Inner Diameter(φ): 63, Stroke(mm): 125, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Double rod, Main Body Shape: Standard, Additional Function: With fall prevention function / With Brake / With Intermediate Stop Function, Environment, Applications: Standard, Cushion: With cushions on both sides, Operating Pressure(MPa): 0.08 to 1.0, Specification
Cylinder (Tube) Inner Diameter(φ): 63, Stroke(mm): 150, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Single Rods, Main Body Shape: Standard, Additional Function: With fall prevention function / With Brake / With Intermediate Stop Function, Environment, Applications: Standard, Cushion: With cushions on both sides, Operating Pressure(MPa): 0.08 to 1.0, Specification
Cylinder (Tube) Inner Diameter(φ): 63, Stroke(mm): 175, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Single Rods, Main Body Shape: Standard, Additional Function: With fall prevention function / With Brake / With Intermediate Stop Function, Environment, Applications: Standard, Cushion: With cushions on both sides, Operating Pressure(MPa): 0.08 to 1.0, Specification
Cylinder (Tube) Inner Diameter(φ): 63, Stroke(mm): 250, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Single Rods, Main Body Shape: Standard, Additional Function: With fall prevention function / With Brake / With Intermediate Stop Function, Environment, Applications: Standard, Cushion: None, Operating Pressure(MPa): -, Specification: -, Port thread type:
Cylinder (Tube) Inner Diameter(φ): 63, Stroke(mm): 355, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Double rod, Main Body Shape: Standard, Additional Function: With fall prevention function / With Brake / With Intermediate Stop Function, Environment, Applications: Standard, Cushion: With cushions on both sides, Operating Pressure(MPa): 0.08 to 1.0, Specification
Cylinder (Tube) Inner Diameter(φ): 63, Stroke(mm): 500, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Double rod, Main Body Shape: Standard, Additional Function: With fall prevention function / With Brake / With Intermediate Stop Function, Environment, Applications: Standard, Cushion: With cushions on both sides, Operating Pressure(MPa): 0.08 to 1.0, Specification
Magnet: D (Built-in), Mounting: B (Basic Style), Style: Aluminum Tube, Bore Size: 63mm, Thread: TN (NPT), Stroke: 25mm, Option: w/o Rod Boot, Cushion: Both Sides (Air-hydro has No Cushion), Lock Operation: D (Spring/Air Pressure Lock)
Magnet: D (Built-in), Mounting: B (Basic Style), Style: Aluminum Tube, Bore Size: 63mm, Thread: TN (NPT), Stroke: 500mm, Option: N [w/o Rod Boot, w/o Cushion (Not Valid for Air-hydro), Lock Operation: D (Spring/Air Pressure Lock)