Cylinder (Tube) Inner Diameter(φ): 100, Stroke(mm): 350, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Double rod, Main Body Shape: Standard, Additional Function: With fall prevention function / With Brake / With Intermediate Stop Function, Environment, Applications: Standard, Cushion: With cushions on both sides, Operating Pressure(MPa): 0.08 to 1.0, Specification
Cylinder (Tube) Inner Diameter(φ): 100, Stroke(mm): 500, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Single Rods, Main Body Shape: Standard, Additional Function: With fall prevention function / With Brake / With Intermediate Stop Function, Environment, Applications: Standard, Cushion: None, Operating Pressure(MPa): -, Specification: -, Port thread type:
Magnet: Built-in, Mounting: Double Clevis, Style: Aluminum Tube, Bore Size: 100mm, Thread: NPT, Stroke: 125mm, Option: w/o Rod Boot, Cushion: Both Sides (Air-hydro has No Cushion), Lock Operation: E [Spring Lock (Lock Exhaust)], Auto Switch: -, Lead Wire or Prewied Connector: -, Number: -
Magnet: Built-in, Mounting: Double Clevis, Style: Aluminum Tube, Bore Size: 100mm, Thread: NPT, Stroke: 800mm, Option: w/o Rod Boot, Cushion: Both Sides (Air-hydro has No Cushion), Lock Operation: E [Spring Lock (Lock Exhaust)], Auto Switch: -, Lead Wire or Prewied Connector: -, Number: -
Magnet: Built-in, Mounting: Double Clevis, Style: Aluminum Tube, Bore Size: 100mm, Thread: NPT, Stroke: 300mm, Option: J [Nylon Tarpaulin, Cushion: Both Sides (Air-hydro has No Cushion)], Lock Operation: E [Spring Lock (Lock Exhaust)], Auto Switch: -, Lead Wire or Prewied Connector: -, Number: -
Magnet: Built-in, Mounting: Double Clevis, Style: Aluminum Tube, Bore Size: 100mm, Thread: NPT, Stroke: 250mm, Option: w/o Rod Boot, Cushion: Both Sides (Air-hydro has No Cushion), Lock Operation: E [Spring Lock (Lock Exhaust)], Auto Switch: -, Lead Wire or Prewied Connector: -, Number: -
Cylinder (Tube) Inner Diameter(φ): 100, Stroke(mm): 150, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Single Rods, Main Body Shape: Standard, Additional Function: With fall prevention function / With Brake / With Intermediate Stop Function, Environment, Applications: Standard, Cushion: None, Operating Pressure(MPa): -, Specification: -, Port thread type:
Cylinder (Tube) Inner Diameter(φ): 100, Stroke(mm): 175, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Single Rods, Main Body Shape: Standard, Additional Function: With fall prevention function / With Brake / With Intermediate Stop Function, Environment, Applications: Standard, Cushion: None, Operating Pressure(MPa): -, Specification: -, Port thread type:
Cylinder (Tube) Inner Diameter(φ): 100, Stroke(mm): 300, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Double rod, Main Body Shape: Standard, Additional Function: With fall prevention function / With Brake / With Intermediate Stop Function, Environment, Applications: Standard, Cushion: With cushions on both sides, Operating Pressure(MPa): 0.08 to 1.0, Specification
Cylinder (Tube) Inner Diameter(φ): 100, Stroke(mm): 350, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Double rod, Main Body Shape: Standard, Additional Function: With fall prevention function / With Brake / With Intermediate Stop Function, Environment, Applications: Standard, Cushion: With cushions on both sides, Operating Pressure(MPa): 0.08 to 1.0, Specification
Cylinder (Tube) Inner Diameter(φ): 100, Stroke(mm): 500, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Single Rods, Main Body Shape: Standard, Additional Function: With fall prevention function / With Brake / With Intermediate Stop Function, Environment, Applications: Standard, Cushion: None, Operating Pressure(MPa): -, Specification: -, Port thread type:
Module Error (914) E < Details > This is generated when the parameters are not set. Turn off the control and motor drive power supplies. No data Error (915) E
VH600 VR Option VH300 VH410 VH VH300/400 Bottom ported VH210 VHS VH200/300/400 Panel mounted All models applicable Different P port location (On handle side) Note that 1(P) port of VH600 is located on handle side as standard.
900 1000 700 600 500 400 300 200 100 0 E 800 900 1000 700 600 500 400 300 200 100 0 F 800 900 1000 700 600 500 400 300 200 100 0 G When the cylinder is extended, the speed controller is metered-out, is connected with the cylinder directly, and its needle is fully open.
[Torque: Less than 0.1 Nm] Push-turn locking lever type [Type E] While pressing the lever down, turn it in the direction of the arrow. If it does not turn, it can be operated the same way as the non-locking type. Plug position Actuation type B port N.C. A port N.O.
Body size Standby E/P regulator Standby regulator Residual Pressure Relief valve 20 EXA1-AC2 30 EXA1-AC1 EXA1-AC2 40 60 EXA1-AC1 -14No.PF-OMA1007-B Names and Functions of Individual Parts Air Management System (Standby E/P regulator type) No.
q IN OUT t e q r IN OUT w r w AR30(K)-B/AR40(K)-B q t AR50(K)-B/AR60(K)-B e IN OUT q t r w e IN OUT r w Component Parts No.
Actuator Specifications Supplement 1.1 Initial setting of LEY/LEYG series Model LEY16/LEYG16 LEY25/LEYG25 LEY32/LEYG32 LEY40/LEYG40 Lead symbol A B C A B C A B C A B C Lead [mm] 10 5 2.5 12 6 3 16 8 4 16 8 4 Stroke (mm) 300 300 300 400 400 400 500 500 500 500 500 500 Max. speed [mm/s] 500 250 125 500 250 125 500 250 125 300 150 75 Min. speed [mm/s] (Independent and interpolation) 15 8 4 18
Actuator Specifications Supplement 1.1 Initial setting of LEY/LEYG series Model LEY16/LEYG16 LEY25/LEYG25 LEY32/LEYG32 LEY40/LEYG40 Lead symbol A B C A B C A B C A B C Lead [mm] 10 5 2.5 12 6 3 16 8 4 16 8 4 Stroke [mm] 300 300 300 400 400 400 500 500 500 500 500 500 Max. speed [mm/s] 500 250 125 500 250 125 500 250 125 300 150 75 Min. speed [mm/s] (Independent and 15 8 4 18 9 5 24 12 6 24
During Auto tuning Auto tuning failure A T 1 E R R 1 9 P V < 2 3 . 0 C # 1 A T F a i l u r e A u t o T u n i n g M O D E S h u t O f f C a n c e l : A T k e y <4> External sensor sampling cycle setting: Mode indication External Sensor Sampling Cycle. Default value: 180 sec. Setting range 10 to 999 sec.