SMC Corporation of America
Elite Part Number Search
Search Results "CDLA2D80-25-P"

ZP2-16UCL ZP (10, 13, 16) U ZP (10, 13, 16) C ZP (10, 13, 16) B ZP (10, 16) D ZPT2-A5, A6 ZPT2-B5, B6 B01, N01 T01 P. 72 P. 73 ZP (20, 25, 32) U ZP (20, 25, 32) C ZP (20, 25, 32) B ZP25D ZP2-B25J ZP2-B30J ZP2-25UCL ZP2-32UCL ZPT3-A6, A8 ZPT3-B5, B6, B8 B01, N01 T01 P. 72 P. 73 ZP (40, 50) U ZP (40, 50) C ZP (40, 50) B ZP40D ZPT4-A6, A8 ZPT4-B6, B8 B01, N01 T01 ZP2-40UCL ZP2-50UCL P. 72 P

)5 1 (P) 3(R2) VQZ r r e q w e q w SQ VFS VFR VQ7 VQ2300 VQ2400 VQ2301 VQ2401 2(B) (A)4 2(B) (A)4 2(B) (A)4 2(B) (A)4 (R1)5 1 (P) 3(R2) (R1)5 1 (P) 3(R2) (R1)5 1 (P) 3(R2) (R1)5 1 (P) 3(R2) r r VQ2500 VQ2501 2(B) (A)4 2(B) (A)4 (R1)5 1 (P) 3(R2) (R1)5 1 (P) 3(R2) e q w VQ2A01 VQ2B01 4(A) 2(B) 2(B) 4(A) r 5(R1) 1(P) 3(R2) 5(R1) 1(P) 3(R2) VQ2C01 2(B) 4(A) 5(R1) 1(P) 3(R2) Component Parts Component

9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com JIS Symbol Double acting, Single rod 5, 10, 15, 20, 25, 30, 40, 50 20, 25, 32 For "Long Stroke", refer to P. 36.

Determination of pressure (P) when making intermediate stop P Ps P > Ps (Refer to page 8-31-1.) Note 2) (For intermediate stops, refer to page 8-15-74.)

Port size Rc1/4, NPT1/4, G1/4(ISO1179) U P DOWN U P DOWN U P DOWN SET SET SET Model with initial display settings of PSI is also available as standard.

(N)VV4Z1 20 S TAT I O N S 1 T H R E A D T Y P E 02 2 Stations to 20 20 Stations PT 00T NPTF D I M E N S I O N S M A N I F O L D T Y P E 20 T O P P O R T E D M P L U G T Y P E F Bracket O P T I O N D I M E N S I O N S M A N I F O L D T Y P E 20 T O P P O R T E D G R O M M E T T Y P E Lead Wire Length ACCESSORIES M A N I F O L D T Y P E 20 T O P P O R T E D DXT170-25-1A Blanking Plate Assembly

Model Port size A B C D M N P R B B E F G H J K L AL 58 90 117 117 154 164 195 200 205 M5 X 0.8 11 17 25 35 37.5 40.5 48 48 48 70 103.5 140 150 184.5 189.5 268 282 282 26 56.8 60.8 60.8 65.5 69.5 75.5 75.5 78 25 40 53 53 70 70 90 95 95 29 45 58.5 58.5 77 82 97.5 102.5 102.5 25 30 41 41 50 50 70 70 70 4.5 5.5 7 7 9 9 12 12 12 20 24 35 35 40 40 50 50 50 17.5 22 34.2 34.2 42.2 46.2 55.2 55.2

VQ1000 Series P.1.10-124 P.1.10-128 P.1.10-132 Plug-in Plug lead VQ2000 Series P.1.10-124 P.1.10-128 P.1.10-132 VQ0 Series P.1.10-170 P.1.10-174 VQ1000 Series P.1.10-170 P.1.10-174 P.742 1.10-114 Manifold Variations T L C S Port size SUP EXH port Cylinder port kit kit kit Lead wire Direct electrical entry style Serial transmission unit Terminal box (Terminal block) SY P, R A, B Enables single-wire

1 (A, B port) 25 25 25 20 15.4 12 2.5 5 14.5 19.5 G 3/8 Electrical entry 39.1 5 x 1/4" 1(P), 4(A), 2(B), 5(R1), 3(R2) port 43.8 53.6 < >: AC Note) When using this valve for IP65, mount a seal connector to the electrical entry. 560 VQ1000/2000 1021Semi-standard Different Number of Connector Pins F and P kits with the following number of pins are available besides the standard number (F = 25P

1 (A, B port) 25 25 25 20 15.4 12 2.5 5 14.5 19.5 G 3/8 Electrical entry 39.1 5 x 1/4" 1(P), 4(A), 2(B), 5(R1), 3(R2) port 43.8 53.6 < >: AC Note) When using this valve for IP65, mount a seal connector to the electrical entry. 560 VQ1000/2000 1021Semi-standard Different Number of Connector Pins F and P kits with the following number of pins are available besides the standard number (F = 25P

100 80 63 P=0.5MPa P=0.5MPa 100 50 50 40 25 20 10 40 20 30 Load weight m (kg) Load weight m (kg) 32 2 3 4 5 25 20 16 10 5 4 16 2 3 1 1 0.2 0.3 0.4 0.5 0.5 0.2 0.3 0.4 0.1 10 100 0.1 10 100 20 30 40 200 50 50 200 20 30 40 Eccentric distance l (mm) Eccentric distance l (mm) Over 50 stroke Over 100 stroke P=0.5MPa 100 80 63 P=0.5MPa 20 100 25 50 Load weight m (kg) 10 Load weight m (kg) 40 32

2 B P 1 P 1 One-touch fitting [1(P), 3/5(E) port] Applicable tubing O.D.

The labels shown below are used on manifold stations containing SUP/EXH block disk(s) to show their location. (3 pcs. each) L (7.5) VZ3000-123-1A 8 Label for EXH block disk Label for SUP/EXH block disk Label for SUP block disk (35) (25) P R P R P R P R P R 5.5 Air Preparation Equipment Pressure Control Equipment Flow Control Equipment Pressure Switches/ Pressure Sensors [Rail mounting pitch

(17.5) 1/2 40 37 128 41 60 30 50 3 14 14 100 71 16 110 M12 x 1.75 10 With Rod Boot (mm) (mm) With Air Cushion (mm) Bore size Rc, NPT port WA WB W WH GA GB P 20 12 10 (12) M5 x 0.8 16 15 (16) 25 1.5 25 12.5 10 (12.5) M5 x 0.8 16 14.5 (16) 25 1.5 32 12 10 (12) 1/8 16 14 (16) 25 1.5 40 13 10 (13) 1/8 17 15 (17) 20 1.5 50 14 12 (14) 1/4 18 16 (18) 20 3 63 14 12 (14) 1/4 18 17 (18) 20 3 80 20

Holding voltage is 25% of the starting voltage (the application method is shown on the back of the solenoid coil). Example) 24VDC Starting voltage Holding voltage Voltage 6VDC 0.15 to 0.2 Time s 28 High Vacuum Angle Valve Series XLS Specifications XLS-25-P G Model XLS-16 XLS-25 XLS-16-P G Normally closed (N.C.)

Holding voltage is 25% of the starting voltage (the application method is shown on the back of the solenoid coil). Example) 24VDC Starting voltage Holding voltage Voltage 6VDC 0.15 to 0.2 Time s 28 High Vacuum Angle Valve Series XLS Specifications XLS-25-P G Model XLS-16 XLS-25 XLS-16-P G Normally closed (N.C.)

Applicable base VV5Z3-20 VV5Z3-21 Rc 1/8 1(P) port Gasket Caution Applicable base VV5Z3-20 VV5Z3-21 Mounting Screw Tightening Torques M2.5: 0.45 Nm (5(R1), 3(R2) port) 3-3-25 25 Series VZ3000 Type 20 Manifold VV5Z3-20Station 1 Grommet (G), (H) (4(A), 2(B) port) (Pitch) (Mounting hole) 6-Rc 1/8 (1(P), 3/5(R) port) Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080

A G E G A S K E T: N I P P L E: M-3N M-5N U N I V E R S A L T E E: M-3UT M-5UT P L U G: M-3P M-5P M-5G1 M-3G P R O D U C T S E L E C T O R P R O D U C T S E L E C T O R P R O D U C T S E L E C T O R P R O D U C T S E L E C T O R P R O D U C T S E L E C T O R E L B O W: M-5L G A S K E T: M-5GH T E E: M-5T H O S E N I P P L E: M-5H-4 M-5H-6 H O S E E L B O W: M-5HL-4 M-5HL-6 Similar to Picture

25 25 1 l/min (ANR) {In the case of Inlet air pressure 0.7 MPa} Bracket Assembly (Accessory) Part No.