Applicable load IC circuit, Relay, PLC Load voltage 24 V or less 48 V or less 100 V or less AC DC AC DC AC DC Maximum load current 50 mA 40 mA 20 mA Contact protection circuit None Internal resistance 1 or less (including lead wire length of 3 m) D-A93, D-A93V, D-A96, D-A96V (With indicator light) D-A93, D-A93V D-A96, D-A96V Auto switch part no.

resistance D-A93, D-A93V, D-A96, D-A96V (with indicator light) D-A93, D-A93V D-A96, D-A96V Switch model Applicable load Relay, PLC IC circuit Caution Load voltage 24 VDC 4 to 8 VDC 100 VAC Operating Precautions Load current range and Maximum load current 20 mA 5 to 40 mA 5 to 20 mA Note 2) Fix the switch with appropriate screw installed on the switch body.

load current 50 mA 40 mA 20 mA Contact protection circuit None 1 or less (including lead wire length of 3 m) Internal resistance D-A93/D-A93V/D-A96/D-A96V (with indicator light) D-A93/D-A93V D-A96/D-A96V Auto switch model Relay, PLC IC circuit Applicable load Caution Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside

IC circuit, Relay, PLC Applicable load 24 V AC/DC or less Load voltage 48 V AC/DC or less 100 V AC/DC or less Maximum load current 50 mA 40 mA 20 mA Contact protection circuit None 1 or less (including lead wire length of 3 m) Internal resistance D-A93/D-A93V/D-A96/D-A96V (with indicator light) D-A93/D-A93V D-A96/D-A96V Auto switch part no.

port Rc1/8 Dimensions/With DIN rail Station L1 L2 L3 2 70 105 140 3 105 140 175 4 140 175 210 5 175 210 245 6 210 245 280 3.8-6 ISA Guide for Use/Design Data When designing a pneumatic circuit with an Air-Catch Sensor, please refer to the data below.

resistance D-A93, D-A93V, D-A96, D-A96V (with indicator light) D-A93, D-A93V D-A96, D-A96V Switch model Applicable load Relay, PLC IC circuit Caution Load voltage 24 VDC 4 to 8 VDC 100 VAC Operating Precautions Load current range and Maximum load current 20 mA 5 to 40 mA 5 to 20 mA Note 2) Fix the switch with appropriate screw installed on the switch body.

CE marking D-A93, D-A93V, D-A96, D-A96V (With indicator light) Precautions Caution D-A96, D-A96V D-A93, D-A93V Auto switch model Applicable load IC circuit Relay, PLC 24 VDC Load voltage 100 VAC 4 to 8 VDC Fix the auto switch with the existing screw installed on the auto switch body.

DZ/Y/YZ VFS3320-D/DZ/Y/YZ VFS3420-D/DZ/Y/YZ VFS3520-D/DZ/Y/YZ Lead wire O.D.

DZ/Y/YZ VFS3320-D/DZ/Y/YZ VFS3420-D/DZ/Y/YZ VFS3520-D/DZ/Y/YZ Lead wire O.D.

www.stevenengineering.com I 6.16 VACUUM VACUUM PADS SERIES ZP ZP SERIES VACUUM PADS 288 Standard Options 12 Diameters 4 Types 6 Materials D I M E N S I O N S ZP VA C U U M PA D S D I M E N S I O N S ZP VA C U U M PA D S D I M E N S I O N S ZP VA C U U M PA D S F L AT T Y P E PA D Part No Type A C B D E F Y ZP02U U02 2 2.6 1.2 7 12 0.8 ZP04U U04 4 4.8 1.6 7 12 0.8 D E E P T Y P E PA D ZP06U

Type Applicable cylinder series Auto switch model Applicable magnetic field Electrical entry Wiring (Pin no. in use) Lead wire length Applicable load Indicator light Load voltage D-P3DWASC D-P3DWASE D-P3DWA D-P3DWAL D-P3DWAZ D-P4DWSC D-P4DWSE D-P4DWL D-P4DWZ D-P79WSE D-P74L D-P74Z 2-wire (34) Pre-wired connector 0.3 m 2-wire (14) 0.5 m AC magnetic field (Single-phase AC welding magnetic field

D-A7/A80 D-A7H/A80H D-A73C/A80C D-A79W D-P3DW 13 11 11.5 10.5 11 12 D17 7 14.5 6 15.5 5.5 14 6 14 15.5 -X 397 MK Series Auto Switch Proper Mounting Position (Detection at Stroke End) and its Mounting Height D-F79F/F7NT D-A7/A80 D-A73C/A80C D-A7H/A80H D-A79W D-M9A D-M9AV D-A9 D-A9V D-M9 D-M9V D-M9W D-M9WV D-F7/J79 D-F7V D-J79C D-F7W/J79W D-F7WV D-F7BA/F7BAV B A U 20, 25 20, 25 U B A 32

HS 9-13-16 16 Series MLU Plate Cylinder with Lock Proper Auto Switch Mounting Position Auto Switch Mounting Height (mm) Auto switch model (mm) D-A7H D-A80H D-F7 D-F7 V D-J79 D-F7W D-F7WV D-J79W D-F7BAL D-F7BAVL D-F79F D-A7H D-80H D-F7 D-J79 D-F7W D-79W D-F7NTL D-F79F D-F7BAL D-A73C D-A80C D-J79C D-A79W D-F7LF D-P5DWL D-F7V D-F7WV D-F7BAVL D-J79C D-A79W D-A7 D-A80 D-F7NTL D-A7 D-A80 D-A73C

HS 9 Plate Cylinder with Lock Series MLU Proper auto switch mounting position Auto switch mounting height (mm) Auto switch model (mm) D-A7H D-A80H D-F7 D-F7 V D-J79 D-F7W D-F7WV D-J79W D-F7BAL D-F7BAVL D-F79F D-A7H D-80H D-F7 D-J79 D-F7W D-79W D-F7NTL D-F7F D-F7BAL D-A73C D-A80C D-J79C D-A79W D-F7LF D-P5DWL D-F7V D-F7WV D-F7BAVL D-J79C D-A79W D-A7 D-A80 D-F7NTL D-A7 D-A80 D-A73C D-A80C D-P5DWL

DC specifications of type "D" and "DO" is only available with 12 and 24 V DC.

Single flat Single flat D D D D D D D D C Single flat Single flat (mm) 15 9 18 20 10 20 30 13 22 40 15 30 10 8 14 Size C D Note ) Dimensions and tolerance of the shaft and single flat (a parallel keyway for size 40) are the same as the standard.

Applicable bore size (mm) D B1 C d H1 (mm) Part no.

ZK2 CH A 2 04 L A KQ2P 06 Applicable stations 02 For 2 stations manifold 04 For 4 stations manifold 06 For 6 stations manifold 08 For 8 stations manifold 10 For 10 stations manifold d Models and Dimensions D Symbol Applicable size d A L D Weight [g] Note 06 6 18 35 8 1 White 08 8 20.5 39 10 2 White 07 1/4" 18 35 8.5 1 Orange 09 5/16" 20.5 39 10 2 Orange Connector type 1 D sub-connector (25

D-A93(V) Brown [Red] Contact protection box LED OUT(+) Brown [Red] Reed switch Resistor Weights Zener diode (g) CD-P11 CD-P12 D-A90 D-A90V D-A93 D-A93V D-A96 D-A96V OUT() Blue [Black] Auto switch part no.