Hs Proper auto switch mounting positions Auto switch mounting height (mm) (mm) Auto switch models D-A3 D-G39 D-K39 D-A44 D-A5 D-A6 D-A59W Auto switch models D-F5 D-J5 D-F5W D-J59W D-F5BAL D-F5F D-F5NTL D-F5W D-J59W D-F5BAL D-F5 D-J5 D-A5/A6 D-A3 D-A44 D-G39 D-K39 D-A59W D-F5NTL D-F5F Bore size (mm) Bore size (mm) A B A B A B B A B Hs Hs Ht Hs Ht A Hs 125 125 0 0 2 2 4.5 4.5 8.5 8.5 9.5 9.5

D-A3 D-G39 D-K39 D-A44 D-A5 D-A6 D-A59W Auto switch model D-F5 D-J5 D-F5W D-J59W D-F5BAL D-F59F D-F5NTL D-F59F D-F5W D-J59W D-F5BAL D-F5 D-J5 D-A5/A6 D-A3 D-A44 D-G39 D-K39 MLGP D-A59W D-F5NTL RLQ Bore size (mm) Bore size (mm) MLU A B A B A B A B Hs Hs Ht Hs Hs Ht 125 125 0 0 2 2 4.5 4.5 9.5 9.5 116 126 75.5 69.5 74.5 70 ML1C 140 140 0 0 2 2 4.5 4.5 9.5 9.5 124 134 81 76.5 80 76.5 160 160

Cylinder Speed Chart Bore size Series CS1/CS2 Pressure 0.5 MPa, Load factor 50% Cylinder stroke 300 mm Average velocity (mm/s) System 125 140 160 180 200 250 300 1000 Vertically upward movement Horizontal movement 900 800 700 600 500 400 300 200 100 0 A 800 900 1000 700 600 500 400 300 200 100 0 B 900 1000 800 700 600 500 400 300 200 100 0 C 800 900 1000 700 600 500 400 300 200 100 0 D 800

Cv Effective area (mm2) Model Construction/Components AC AC, DC 1.0 0.5 0.3 1.0 0.5 0.3 VX311 -01 0 2 4 VX312 -01 0 2 4 VX313 -01 VX311 -02 1.5 2.2 3 1.5 0.08 0.16 0.24 0.08 0.16 1.4 2.8 4.3 1.4 2.8 0.6 0.3 0.2 0.6 0.3 0.6 1.0 0.2 0.3 0.6 0.15 0.3 0.6 1.0 0.3 0.6 0.15 0.3 1 8 (6A) 0 2 4 0 2 4 0 2 4 VX312 -02 330 2.2 VX3224-02 VX3324-02 550 700 330 550 700 550 700 550 700 550 700 550 700

C plane to A plane D plane to B plane 0.1 or less 0.1 or less Bottom mounting Top mounting Maximum work load (N) Repeatable positioning accuracy (mm) Horizontal Mounting position Stroke (mm) Motor output (W) Typical model Maximum speed (mm/s) Individual models Applicable controller model Feed screw 100 200 300 400 500 600 700 800 9001 0001 200 Ground ball screw lead 10mm Rolled ball screw

See the table below Belt tension Size Belt N Part number Bolts LEF25 LE-D-6-2 19.6 pull LEF32 LE-D-6-3 49.0 LEF40 LE-D-6-4 98.1 4. "Pulley plate" is installed. Bolts Size Tightening torque (Nm) M3 0.6310% M4 1.510% M5 310% 8.Troubleshooting When a fault occurs during the operation, the corresponding alarm or warning is displayed.

0 t r i w y e q o Replacement Parts (For valve) Description VQ7-8-FG-SVQ7-8-FG-DVQ7-8-FPG-DVQ7-8-FG-S-R VQ7-8-FG-D-R VQ7-8--D-R VQ7-8--DNumber q w e r t y u i o !

D-F5LF (2 color indicator) D-A53 D-A54 D-A56 D-A64 D-A67 D-A59W (2 color indicator) Single rod Series MNB 40 50 63 80 100 25 to 500 Cylinder with Lock Series MNB Tie-rod mounting type 25 to 600 Double acting Double rod Series MNBW 25 to 700 Feature 2 Cylinder with Lock Double Acting: Single Rod Series MNB 32, 40, 50, 63, 80, 100 How to Order MNB L 50 100 D Standard type With auto switch

Insert D at the end of the manifold part number.

unit only (kPa) P With unit switching function (Initial value psi) D Vacuum pressure switch *3 For q, the units for metric spec. fittings are in kPa.

Magnet: D (Built-in Magnet), Mounting: F (Rod Flange), Tube Material: Aluminum Tube, Bore Size: 40mm, Thread: TN (NPT), Stroke: 75mm, Bellows/Cushion: Cushion Both Sides, Auto Switch: No Switch, Lead Wire or Prewired Connector: 0.5m (Or None in the Case of No Switch), Number: 2 pcs. (Or None in the Case of No Switch), Made to Order: XC35 (w/Coil Scrapper)

Magnet: D (Built-in Magnet), Mounting: F (Rod Flange), Tube Material: Aluminum Tube, Bore Size: 40mm, Thread: TN (NPT), Stroke: 50mm, Bellows/Cushion: Cushion Both Sides, Auto Switch: No Switch, Lead Wire or Prewired Connector: 0.5m (Or None in the Case of No Switch), Number: 2 pcs. (Or None in the Case of No Switch), Made to Order: XC35 (w/Coil Scrapper)

Cylinder (Tube) Inner Diameter(φ): 40, Stroke(mm): 200, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Single Rods, Main Body Shape: Standard, Additional Function: With fall prevention function / With Brake / With Intermediate Stop Function, Environment, Applications: Standard, Operating Temperature(°C): -10~70, End Locking: [Included] Presence, Valves: No

Cylinder (Tube) Inner Diameter(φ): 40, Stroke(mm): 200, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Double rod, Main Body Shape: Standard, Additional Function: With fall prevention function / With Brake / With Intermediate Stop Function, Environment, Applications: Standard, Operating Temperature(°C): -10~70, End Locking: [Included] Presence, Valves: No,

Cylinder (Tube) Inner Diameter(φ): 40, Stroke(mm): 200, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Double rod, Main Body Shape: Standard, Additional Function: With fall prevention function / With Brake / With Intermediate Stop Function, Environment, Applications: Standard, Operating Temperature(°C): -10~70, End Locking: [Included] Presence, Valves: No,

Cylinder (Tube) Inner Diameter(φ): 40, Stroke(mm): 300, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Double rod, Main Body Shape: Standard, Additional Function: With fall prevention function / With Brake / With Intermediate Stop Function, Environment, Applications: Standard, Operating Temperature(°C): -10~70, End Locking: [Included] Presence, Valves: No,

Additional Function: With fall prevention function / With Brake / With Intermediate Stop Function, Environment, Applications: Standard, Operating Temperature(°C): -10~70, End Locking: [Included] Presence, Valves: No, Operating Pressure(MPa): 0.08~1.0, Cushion: With cushions on both sides, Specification: Built-in magnet, Support bracket: Rod-end flange type, Port thread type: NPT, Auto Switches: M9B

Cylinder (Tube) Inner Diameter(φ): 40, Stroke(mm): 200, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Single Rods, Main Body Shape: Standard, Additional Function: With fall prevention function / With Brake / With Intermediate Stop Function, Environment, Applications: Standard, Operating Temperature(°C): -10~70, End Locking: [Included] Presence, Valves: No

Cylinder (Tube) Inner Diameter(φ): 40, Stroke(mm): 200, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Double rod, Main Body Shape: Standard, Additional Function: With fall prevention function / With Brake / With Intermediate Stop Function, Environment, Applications: Standard, Operating Temperature(°C): -10~70, End Locking: [Included] Presence, Valves: No,

Cylinder (Tube) Inner Diameter(φ): 40, Stroke(mm): 200, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Double rod, Main Body Shape: Standard, Additional Function: With fall prevention function / With Brake / With Intermediate Stop Function, Environment, Applications: Standard, Operating Temperature(°C): -10~70, End Locking: [Included] Presence, Valves: No,