SMC Corporation of America
Elite Part Number Search
Search Results "CDQ2B80-50DCZ-L-M9PW"

Applicable bore size A1 E1 D1 L1 MM R1 U1 ND NX NZ L Split pin size Flat washer size Shaft diameter: NDH10 Split pin Hole diameter: NDd9 L L MM Flat washer: Polished round D1 D1 MM Y-04D 40 22 24 10 55 M14 x 1.5 13 25 12 16 +0.3 +0.1 38 55.5 3 x 18 L Polished round 12 E1 NX NZ L A1 L1 U1 A1 L1 U1 Y-05D 50, 63 27 28 14 60 M18 x 1.5 15 27 12 16 +0.3 +0.1 38 55.5 3 x 18 L Polished round 12 E1

Load voltage Auto switch model Lead wire length [m] Pre-wired connector Applicable load DC AC 0.5 (Nil) 1 (M) 3 (L) 5 (Z) Indicator light Type Special function Electrical entry Wiring (Output) M9N P P P p p IC circuit 3-wire (NPN) Solid state auto switch 5 V, 12 V 3-wire (PNP) M9P P P P p p 2-wire 12 V M9B P P P p p 3-wire (NPN) 5 V, 12 V M9NW P P P p p IC circuit 3-wire (PNP) M9PW P P

Centralized piping on right R R L L R L Slide table actuation direction Centralized piping on left R L L R R L Slide table actuation direction 2. The plug position of the piping port can be changed to suit the operating conditions. When screwing in the plug for the second time, wrap a sealant tape around the plug to prevent leakage. (1) M5 First tighten lightly until the rotation stops.

point L (mm) 120 80 160 200 20 40 60 Gripping point L (mm) 80 0 20 40 60 Gripping point L (mm) 80 100 120 MHW2-25D MHW2-40D 160 50 Pressure 0.7 MPa Pressure 0.7 MPa MHZ 140 0.6 0.6 40 120 Gripping force (N) Gripping force (N) 0.5 0.5 MHF 100 30 0.4 0.4 80 0.3 MHL 0.3 0.2 20 60 0.2 40 MHR 10 20 MHK 0 20 40 60 Gripping point L (mm) 100 80 80 100 120 140 160 0 20 40 60 Gripping point L (mm)

Lead wire length (m) Load voltage Indicator light Auto switch model None (N) Applicable load Special function Type Electrical entry Pre-wired connector Wiring (Output) 0.5 (Nil) 3 (L) 1 (M) 5 (Z) DC AC M9N M9P M9B H7C G39 K39 M9NW M9PW M9BW H7BA H7NF 3-wire (NPN) IC circuit 5V,12V 3-wire (PNP) Grommet Relay, PLC Reed switch Solid state switch 2-wire 12V Connector IC circuit 3-wire (NPN)

Lead wire length (m) Load voltage Indicator light Auto switch model None (N) Applicable load Special function Type Electrical entry Pre-wired connector Wiring (Output) 0.5 (Nil) 3 (L) 1 (M) 5 (Z) DC AC M9N M9P M9B H7C G39 K39 M9NW M9PW M9BW H7BA H7NF 3-wire (NPN) IC circuit 5V,12V 3-wire (PNP) Grommet Relay, PLC Reed switch Solid state switch 2-wire 12V Connector IC circuit 3-wire (NPN)

Follow the appropriate procedure (R or L) shown in Table 2.

Cylinder (Tube) Inner Diameter(φ): 32, Stroke(mm): 50, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Single Rods, Main Body Shape: [Block Shape] Block shape, Additional Function: Standard, Environment, Applications: Standard, Operating Temperature(°C): -10~60, Operating Pressure(MPa): 0.05~1, Cushion: None, Specification: Built-in magnet, Support bracket:

Double Acting, Rod Operation Method: Single Rods, Main Body Shape: [Block Shape] Block shape, Additional Function: Standard, Environment, Applications: Standard, Operating Temperature(°C): -10~60, Operating Pressure(MPa): 0.05~1, Cushion: None, Specification: Built-in magnet, Support bracket: Through-hole (standard), Port thread type: Rc, Body Options: With rubber bumper, Auto Switches: M9PW

Cylinder (Tube) Inner Diameter(φ): 50, Stroke(mm): 50, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Single Rods, Main Body Shape: [Block Shape] Block shape, Additional Function: Standard, Environment, Applications: Standard, Operating Temperature(°C): -10~60, Operating Pressure(MPa): 0.05~1, Cushion: None, Specification: Built-in magnet, Support bracket:

Cylinder (Tube) Inner Diameter(φ): 25, Stroke(mm): 50, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Single Rods, Main Body Shape: [Block Shape] Block shape, Additional Function: Standard, Environment, Applications: Standard, Operating Temperature(°C): -10~60, Operating Pressure(MPa): 0.05~1, Cushion: None, Specification: Built-in magnet, Support bracket:

Cylinder (Tube) Inner Diameter(φ): 25, Stroke(mm): 50, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Double rod, Main Body Shape: [Block Shape] Block shape, Additional Function: Standard, Environment, Applications: Standard, Operating Temperature(°C): -10~60, Operating Pressure(MPa): 0.05~1, Cushion: None, Specification: Built-in magnet, Support bracket:

Cylinder (Tube) Inner Diameter(φ): 32, Stroke(mm): 50, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Single Rods, Main Body Shape: [Block Shape] Block shape, Additional Function: Standard, Environment, Applications: Standard, Operating Temperature(°C): -10~60, Operating Pressure(MPa): 0.05~1, Cushion: None, Specification: Built-in magnet, Support bracket:

Double Acting, Rod Operation Method: Single Rods, Main Body Shape: [Block Shape] Block shape, Additional Function: Standard, Environment, Applications: Standard, Operating Temperature(°C): -10~60, Operating Pressure(MPa): 0.05~1, Cushion: None, Specification: Built-in magnet, Support bracket: Through-hole (standard), Port thread type: Rc, Body Options: With rubber bumper, Auto Switches: M9PW

Cylinder (Tube) Inner Diameter(φ): 50, Stroke(mm): 50, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Single Rods, Main Body Shape: [Block Shape] Block shape, Additional Function: Standard, Environment, Applications: Standard, Operating Temperature(°C): -10~60, Operating Pressure(MPa): 0.05~1, Cushion: None, Specification: Built-in magnet, Support bracket:

Cylinder (Tube) Inner Diameter(φ): 25, Stroke(mm): 50, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Single Rods, Main Body Shape: [Block Shape] Block shape, Additional Function: Standard, Environment, Applications: Standard, Operating Temperature(°C): -10~60, Operating Pressure(MPa): 0.05~1, Cushion: None, Specification: Built-in magnet, Support bracket:

Cylinder (Tube) Inner Diameter(φ): 25, Stroke(mm): 50, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Double rod, Main Body Shape: [Block Shape] Block shape, Additional Function: Standard, Environment, Applications: Standard, Operating Temperature(°C): -10~60, Operating Pressure(MPa): 0.05~1, Cushion: None, Specification: Built-in magnet, Support bracket: