Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com Performance/Specifications General specifications LC5-1-T1-02 Part no.
Performance/Specifications General specifications LC5-1-T1-02 Part no.
Size: 46 (42.5 O.D.), Display Pressure: P4 (0.4MPa, 60psi), Connection Thread: 02 (R 1/4), Clear Cover Material: Polycarbonate, Attachment: C (Clear Cover Non Removable, Wrench Tighten), Option: X30 (Both MPa and psi)
Type: -, Maximum Indicated Pressure(Mpa): -, Outer Diameter(φ): -, Shape: Back side thread, Maximum Indicated Pressure: 0.4 MPa / 60 psi, Connection screw: R 1/4, Transparent cover material: Polycarbonate, Special Configurations: Both MPa and psi, Attachment: Clear cover has a protrusion (clear cover can be removed)
Size: 42.5 O.D., Display Pressure: 0.4MPa, 60psi, Connection Thread: R 1/4, Clear Cover Material: Polycarbonate, Attachment: Clear Cover Non Removable, Wrench Tighten, Option: Both MPa and psi
Size: 42.5 O.D., Display Pressure: 1.0MPa, 150psi, Connection Thread: R 1/4, Clear Cover Material: Polycarbonate, Attachment: Clear Cover Removable, Hand Tighten, Option: Both MPa and psi
B3 A3 (d) (5.7) 15 16 83 L (11) (30.7) No.SFOD-OMT0009CN-B 10.7 I/O J X C C 2 * L 1 1.5m 40 AWG AWG28 3 3m 5 5m PLC (7.5) R1.25-4(M4 ) 40 20 39 . . . 2 21 1 L PLC 1.27mm No.
Size: 42.5 O.D., Display Pressure: 0.2MPa, 30psi, Connection Thread: NPT 1/8, Clear Cover Material: Nylon, Attachment: w/o Cover Ring Assembly/None, Option: Both MPa and psi
Size: 42.5 O.D., Display Pressure: 0.2MPa, 30psi, Connection Thread: NPT 1/4, Clear Cover Material: Nylon, Attachment: w/o Cover Ring Assembly/None, Option: Both MPa and psi
Size: 42.5 O.D., Display Pressure: 0.2MPa, 30psi, Connection Thread: R 1/8, Clear Cover Material: Nylon, Attachment: w/o Cover Ring Assembly/None, Option: Both MPa and psi
SMC offers a variety of pressure gauges including general purpose, oil-free/external parts copper-free with limit indicator, clean series and a pressure gauge with a pressure switch. Pressure ranges vary from 0 to 1.5MPa, depending on the selected gauge. Panel mounting is possible.General purpose gauge w/limit indicator , Back or vertical side thread , Indication precision: ±3% F.S. (full
SMC offers a variety of pressure gauges including general purpose, oil-free/external parts copper-free with limit indicator, clean series and a pressure gauge with a pressure switch. Pressure ranges vary from 0 to 1.5MPa, depending on the selected gauge. Panel mounting is possible.General purpose gauge w/limit indicator , Back or vertical side thread , Indication precision: ±3% F.S. (full
SMC offers a variety of pressure gauges including general purpose, oil-free/external parts copper-free with limit indicator, clean series and a pressure gauge with a pressure switch. Pressure ranges vary from 0 to 1.5MPa, depending on the selected gauge. Panel mounting is possible.General purpose gauge w/limit indicator , Back or vertical side thread , Indication precision: ±3% F.S. (full
min L/min L/min 0 to 0 to 0 to Accumulated flow display/ Set flow range 0 to 999,999,999 L 9,999,9 99.99 x 99,999, 999.9 L 0 to 999,999,999 L 99,999, 999.9 L 0 to 999,999,999 L 103 L Accumulated flow display/ Min. setting unit 1 L 10 L 0.1 L 1 L 0.1 L 1 L Accumulated pulse flow rate conversion value 0.1 0.5 1 2 5 L/pulse 0.05 L 0.1 L 0.5 L 1 L 2 L 0.05 L 0.1 L 0.5 L L/pulse L/pulse L/pulse
SMC offers a variety of pressure gauges including general purpose, oil-free/external parts copper-free with limit indicator, clean series and a pressure gauge with a pressure switch. Pressure ranges vary from 0 to 1.5MPa, depending on the selected gauge. Panel mounting is possible.General purpose gauge w/limit indicator , Back or vertical side thread , Indication precision: 3% F.S. (full
,lodular type FFL Combinalion Recommended for control of pilot signal: NIT 200 ' OO 2G Elecko-pneumalic regulator Ref. catalog N8-01 HOW TO ORDER x x T I I L aterial I t NIL NBB (Buna) I S Copper Free Extarnal I TFPM (Viton) High Tamperature tP300 42 0 -T-T | l t l Supply & Output Preasure Gauge I t00 no gauge Operution 01 2kgllcrf r bsingte Acring 02 3 kgf/cm'z 03 10kg /cnf 04 4 kgf/cm'?
Please change the parameter in the initial setting. *3 The minimum unit of the travel distance of the actuator should be 1 [m]. *4 When the motor mounting position is right side parallel (LEY*R / LEYG*R) or left side parallel (LEY*L / LEYG*L), the rotation direction selection is 0(+: Counter motors side). -31- Recommended Value of acceleration time constant of Point table No.1 [LEY] LEY25
Please change the parameter in the initial setting. *3 The minimum unit of the travel distance of the actuator should be 1 [m]. *4 When the motor mounting position is right side parallel (LEY*R / LEYG*R) or left side parallel (LEY*L / LEYG*L), the rotation direction selection is 0(+: Counter motors side). -28- LEY63 LEY63D Lead symbol A B C L A B C Series Lead 5(2.86) 20 10 5 20 10 5 (Including
Please change the parameter in the initial setting. *3 When the motor mounting position is right side parallel (LEY*R / LEYG*R) or left side parallel (LEY*L / LEYG*L), the rotation direction selection is 0(+: Counter motors side). * For LECSS, please set the electronic gear with PC, PLC etc. in your application. -23- 6.3.5 Forced stop input selection If the product is used with forced stop
Size: -, Display Pressure: -, Connection Thread: -, Clear Cover Material: -, Attachment: -, Option: -