Cooling Capacity: 012 (Cooling Capacity: 1100/1300W, 50/60 Hz), Cooling Method: A (Air-cooled Refrigeration), Thread: N (NPT w/PT-NPT Conversion Fitting Set), Option: GJM (G + J + M)
Cooling Capacity: 012 (Cooling Capacity: 1100/1300W, 50/60 Hz), Cooling Method: A (Air-cooled Refrigeration), Thread: N (NPT w/PT-NPT Conversion Fitting Set), Option: JM (J + M)
Cooling Capacity: 012 (Cooling Capacity: 1100/1300W, 50/60 Hz), Cooling Method: W (Water-cooled Refrigeration), Thread: Rc, Option: J (Automatic Water Supply Function)
Cooling Capacity: 012 (Cooling Capacity: 1100/1300W, 50/60 Hz), Cooling Method: A (Air-cooled Refrigeration), Thread: F (G w/PT-G Conversion Fitting Set), Option: MT (M + T)
Cooling Capacity: 012 (Cooling Capacity: 1100/1300W, 50/60 Hz), Cooling Method: W (Water-cooled Refrigeration), Thread: F (G w/PT-G Conversion Fitting Set), Option: J (Automatic Water Supply Function)
Cooling Capacity: 012 (Cooling Capacity: 1100/1300W, 50/60 Hz), Cooling Method: A (Air-cooled Refrigeration), Thread: F (G w/PT-G Conversion Fitting Set), Option: B (Earth Leakage Breaker)
Cooling Capacity: 012 (Cooling Capacity: 1100/1300W, 50/60 Hz), Cooling Method: A (Air-cooled Refrigeration), Thread: Rc, Option: BGMT (B + G + M + T)
Thermo-chiller HRS offers convenient functions, self diagnosis and check display for easy maintenance. An angled supply port facilitates the supply of circulating fluid, even when units are stacked. A large digital display provides a clear view of the current and set values. The dustproof filter is integrated with the grill of the front panel allowing mounting and removal of the HRS filter
Thermo-chiller HRS offers convenient functions, self diagnosis and check display for easy maintenance. An angled supply port facilitates the supply of circulating fluid, even when units are stacked. A large digital display provides a clear view of the current and set values. The dustproof filter is integrated with the grill of the front panel allowing mounting and removal of the HRS filter
Thermo-chiller HRS offers convenient functions, self diagnosis and check display for easy maintenance. An angled supply port facilitates the supply of circulating fluid, even when units are stacked. A large digital display provides a clear view of the current and set values. The dustproof filter is integrated with the grill of the front panel allowing mounting and removal of the HRS filter
Cooling Capacity: 012 (Cooling Capacity: 1100/1300W, 50/60 Hz), Cooling Method: A (Air-cooled Refrigeration), Thread: Rc, Option: GM (G + M)
Thermo-chiller HRS offers convenient functions, self diagnosis and check display for easy maintenance.? An angled supply port facilitates the supply of circulating fluid, even when units are?stacked.? A?large digital display provides a clear view of the current and set values.? The dustproof filter is integrated with the grill of the front panel allowing mounting and removal of the HRS?filter
This is a legacy product. Please contact us for the latest version.sales@ocaire.com, THERMO CHILLER, WATER COOLED, OTHERS, HRS THERMO-CHILLERS, 22, HRS - NO SIZE RATING, 92.59414 lb, ModelCooling capacity (W)Cooling methodPower supplyInternational standardsHRS0121100/1300 (50/60 Hz)Air-cooled refrigeration Water-cooled refrigerationSingle-phase 100 VAC (50/60 Hz), 115 VAC (60 Hz)
Thermo-chiller HRS offers convenient functions, self diagnosis and check display for easy maintenance.? An angled supply port facilitates the supply of circulating fluid, even when units are?stacked.? A?large digital display provides a clear view of the current and set values.? The dustproof filter is integrated with the grill of the front panel allowing mounting and removal of the HRS?filter
10.5 40 41 46 20 77 90 102 115 140 12.5 25 37.5 50 75 181 194 206 219 244 27 10.5 Symbol Stroke (mm) With Air Cushion Boss-cut Female Rod End (mm) (mm) Bore size A1 H MM ZZ 20 8 20 M4 x 0.7 95 25 8 20 M5 x 0.8 95 32 12 20 M6 x 1 97 40 13 21 M8 x 1.25 125 Bore size WA 20 13 25 13 32 13 40 16 Bore size ZZ Without With rod boot 1 to 50 51 to 100 101 to 150 151 to 200 201 to 300 20 103 130 143
to 500 30 27 60 22 44 16 32 10 15 8 M8 x 1.25 6 14 40 +0.070 0 0.1 0.3 12 18.0 up to 600 20 to 600 35 32 70 27 52 20 40 10 17 11 M8 x 1.25 7 18 50 +0.070 0 0.1 0.3 16 25.0 up to 600 20 to 600 35 32 85 27 64 20 40 10 17 11 M10 x 1.25 7 18 63 +0.084 0 0.1 0.3 20 31.5 102 13 up to 750 20 to 750 40 37 32 78 25 52 14 21 M12 x 1.75 10 22 80 +0.084 0 0.1 0.3 25 35.5 100 up to 750 20 to 750 40 37
/300-A-40. 8-9 8.2.4 HRSH100/150/200/250-W-20/40. 8-10 8.3 Flow Diagram . 8-11 8.3.1 HRSH-A-20/40. 8-11 8.3.2 HRSH-W-20/40. 8-12 8.4 Cooling Capacity . 8-13 8.4.1 HRSH100-A-20/40. 8-13 8.4.2 HRSH150-A-20/40. 8-13 8.4.3 HRSH200-A-20/40. 8-14 8.4.4 HRSH250-A-20/40. 8-14 8.4.5 HRSH300-A-20/40. 8-15 8.4.6 HRSH100-W-20/40. 8-16 8.4.7 HRSH150-W-20/40. 8-16 8.4.8 HRSH200-W-20/40. 8-17 8.4.9 HRSH250
-W-20/40/46. 8-11 8.4 Cooling capacity . 8-12 HRS Series HRX-OM-S004 Contents 8.4.1 HRS100-A-20/40/46. 8-12 8.4.2 HRS150-A-20/40/46. 8-12 8.4.3 HRS100-W-20/40/46. 8-13 8.4.4 HRS150-W-20/40/46. 8-13 8.5 Pump capacity . 8-14 8.5.1 HRS100/150-A/W-20/40/46. 8-14 8.6 Types of Hazard Labels (HRS--40/46-) . 8-15 8.6.1 Positions of danger warning label . 8-16 8.7 Standards . 8-17 8.8 Sample DoC.
MY1CW16/20 MY1MW16/20 MX B A MTS Reed Switch Solid State Switch D-A90(V), D-A93(V), D-A96(V) (mm) D-M9N(V), D-M9P(V), D-M9B(V) D-F9NW(V), D-F9PW(V), D-F9BW(V) MY 16 20 Mounting position 16 20 Mounting position Mounting position 16 20 93 94 A A A 73 74 70 90 CY 107 106 B B B 87 86 90 110 6.5 7 8.5 6.5 Operating range Note) Operating range Note) Operating range Note) 11 7.5 MG CX MY1MW25/32