PS: Pilot presure supply port, PV: Vacuum pressure supply port, PD: Release pressure supply port Release pressure supply port (PD port) B C None (Release pressure is supplied from the PS port.) Provided (Air can be alternatively supplied from the PS port.)
Relationship between flow rate and PD Relationship between temperature and PD -72No.PF-OMW0010-D Conversion formula of the process data and flow/temperature measurement value (1) Conversion formula from the process data to the flow/temperature measurement value: Pr = a (PD) + b (2) Conversion formula from the flow/temperature gauge measurement value to the process data: (PD) = (Pr b) /
formula from the pressure gauge measurement value to the process data: (PD) = (Pr b) / a Pr: Pressure gauge measurement value and set value PD: Measurement value (process data) a: Inclination b: Intercept [Inclination and intercept to the unit specification] Range Unit Inclination a Intercept b kPa 0.005 0 Pa 0.5 0 2 kPa mbar 0.005 0 (0.002) psi 0.072525 0 mmH2O 0.050985 0 MPa -0.02525
to 5.30 0.35 to 5.55 PD 90 to 1000 65 to 1050 Flow L/min 4.0 to 40.0 2.5 to 45.0 40 L Flow gal/min 1.1 to 10.6 0.7 to 11.9 PD 200 to 1000 63 to 1125 -72No.PF-OMA1011-A Conversion formula of the process data and measurement value (1) Conversion formula from the process data to the measurement value: Pr = a (PD) + b (2) Conversion formula from the measurement value to the process data: (PD
Relationship between flow rate and PD -78No.PF-OMZ0002-A Conversion formula of the process data and flow measurement value (1) Conversion formula from the process data to the flow measurement value: Pr = a (PD) + b (2) Conversion formula from the flow measurement value to the process data: (PD) = (Pr b) / a Pr: Flow measurement value and pressure set value PD: Flow measurement value (process
JIS B 8370: General rules for pneumatic equipment. JIS B 8361: General rules for hydraulic equipment. JIS B 9960-1: Safety of machinery Electrical equipment for machines. (Part 1: General requirements) JIS B 8433-1993: Manipulating industrial robots Safety, etc. *2) Labor Safety and Sanitation Law, etc.
ZQ-OM01301-A Maximum vacuum release flow rate Vacuum release flow rates in product specifications and according to the V port size [L/min (ANR) ] Supply pressure error V Port [MPa] ZQ05A ZQ07A ZQ10A ZQ000A Size Common Individual Common Individual Common Individual Common Individual PD PD PD PD PD PD PD PD 3.2 0.1 16 14 11 23 0.2 26 23 19 38 0.3 39 31 35 28 29 22 52 43 45 39 47 41 38 35 66
Relationship between flow rate and PD -74No.PF-OMY0002 Conversion formula of the process data and flow measurement value (1) Conversion formula from the process data to the flow measurement value: Pr = a (PD) + b (2) Conversion formula from the flow measurement value to the process data: (PD) = (Pr b) / a Pr: Flow measurement value and pressure set value PD: Flow measurement value (process
0 1450.4 -73 1523 (PD) 1000 5000 800 5200 MPa 0 16.000 -0.80 16.80 kgf/cm 2 0 163.15 -8.2 171.3 bar 0 160.00 -8.0 168.0 ISE78G psi 0 2320.6 -116 2437 (PD) 1000 5000 800 5200 ISE70G MPa (PD) PD [MPa] (PD)(ISE70G MPa) -65No.PS-OMV0008CN-E Pr = a (PD) + b (PD) = (Pr b) / a Pr PD a b [] a b MPa 0.00025 -0.25 kPa 0.25 -250 kgf/cm 2 0.00254925 -2.54925 ISE70G bar 0.0025 -2.5
PD) = (Pr b) / a Pr: Pressure gauge measurement value and pressure set value PD: Pressure gauge measurement value a: Inclination b: Intercept [Inclination and intercept to the unit specification] Series Unit Inclination a Intercept b MPa 0.00025 -0.25 kPa 0.25 -250 ISE70G kgf/cm2 0.002549 -2.549 bar 0.0025 -2.5 psi 0.03626 -36.26 MPa 0.0005 -0.5 kPa 0.5 -500 ISE75G kgf/cm2 0.0050985 -5.0985
PD) = (Pr b) / a Pr: Pressure gauge measurement value and pressure set value PD: Pressure gauge measurement value a: Inclination b: Intercept [Inclination and intercept to the unit specification] Series Unit Inclination a Intercept b MPa 0.00025 -0.25 kPa 0.25 -250 ISE20C kgf/cm2 0.00254925 -2.54925 bar 0.0025 -2.5 psi 0.03626 -36.26 MPa -0.025 0.025 kPa -0.025 25 kgf/cm2 -0.000254925 0.254925
0 1.6000 -0.105 1.680 kPa 0 1,600.0 -105 1680 Kgf/cm 2 0 16.315 -1.07 17.13 ISE71 Bar 0 16.000 -1.05 16.80 Psi 0 232.06 -15.2 243.7 (PD) 1000 5000 738 5200 ISE70 MPa (PD) PD [MPa] (PD)(ISE70 MPa) -62No.PS-OMV0003CN-G Pr = a (PD) + b (PD) = (Pr b) / a Pr PD a b [] a b MPa 0.00025 -0.25 kPa 0.25 -250 kgf/cm 2 0.002549 -2.549 ISE70 bar 0.0025 -2.5 psi 0.03626 -36.26 MPa 0.0004
Pressure Range: -100.0 to 100kPa, Piping Specifications: M5 Female Thread/Rear Piping Port, Output Specifications: PNP Open Collector 2 Outputs, Unit Specifications: -, Lead Wire: -, Adapter: -, Calibration Certificate: -
Pressure Range: 0.0 to -101.0kPa, Piping Specifications: M5 Female Thread/Rear Piping Port, Output Specifications: PNP Open Collector 2 Outputs, Unit Specifications: -, Lead Wire: -, Adapter: -, Calibration Certificate: -
PD) = (Pr b) / a Pr: Pressure gauge measurement value and pressure set value PD: Pressure gauge measurement value a: Inclination b: Intercept [Inclination and intercept to the unit specification] Series Unit Inclination a Intercept b MPa 0.00025 -0.25 kPa 0.25 -250 ISE20B kgf/cm2 0.00254925 -2.54925 bar 0.0025 -2.5 psi 0.03626 -36.26 MPa -0.025 0.025 kPa -0.025 25 kgf/cm2 -0.000254925 0.254925
Individual Vacuum l\,ls o 1lA o o o o o o PS M3 o PS M5 o o PD PD o o PE A EXH 1la A A Individual SUP spacer 1PS,lPD, :PE (R1) PV M5 o 1ta o o o o spa@r (R16) lPV, xPS, IPD,lPE 'Common o o PS t\r3 a PS a a PD PD O o PE EXH 1t8 A A each valve unit.
Individual Vacuum l\,ls o 1lA o o o o o o PS M3 o PS M5 o o PD PD o o PE A EXH 1la A A Individual SUP spacer 1PS,lPD, :PE (R1) PV M5 o 1ta o o o o spa@r (R16) lPV, xPS, IPD,lPE 'Common o o PS t\r3 a PS a a PD PD O o PE EXH 1t8 A A each valve unit.
1 IO-Link master Number of ports and connector Symbol Number of ports Connector Port specifications B 4 ports M12 connector Symbol Content A Port Class A B Port Class B Summary of Product parts EX600-L#B1 No.
0.004 -4 psi 0.05802 -58.02 [Calculation example] (1) Conversion from the process data to the pressure measurement value (For ISE70 series, unit specification MPa and PD = 2000) Pr = a (PD) + b = 0.00025 2000 0.25 = 0.25 [MPa] (2) Conversion from the pressure measurement value to the process data (For ISE70 series, unit specification MPa and Pr = 0.75 [MPa]) (PD) = (Pr b) / a = [0.75