With Bracket, Gauge, 1/8" NPT Fitting $152.00 VMW-140-B-G-N02 With Bracket, Gauge, 1/4" NPT Fitting $154.00 VMW-140-B-G-N07 With Bracket, Gauge, 1/4" Push to Connect Fitting $71.00 VMW-140-B-G-N09 With Bracket, Gauge, 5/16" Push to Connect Fitting $71.00 VMW-140-G-N01 With Gauge, 1/8" NPT Fitting $151.00

With Bracket, Gauge, 1/8" NPT Fitting $152.00 VMW-140-B-G-N02 With Bracket, Gauge, 1/4" NPT Fitting $154.00 VMW-140-B-G-N07 With Bracket, Gauge, 1/4" Push to Connect Fitting $71.00 VMW-140-B-G-N09 With Bracket, Gauge, 5/16" Push to Connect Fitting $71.00 VMW-140-G-N01 With Gauge, 1/8" NPT Fitting $151.00

With Bracket, Gauge, 1/8" NPT Fitting $152.00 VMW-140-B-G-N02 With Bracket, Gauge, 1/4" NPT Fitting $154.00 VMW-140-B-G-N07 With Bracket, Gauge, 1/4" Push to Connect Fitting $71.00 VMW-140-B-G-N09 With Bracket, Gauge, 5/16" Push to Connect Fitting $71.00 VMW-140-G-N01 With Gauge, 1/8" NPT Fitting $151.00

With Bracket, Gauge, 1/8" NPT Fitting $152.00 VMW-140-B-G-N02 With Bracket, Gauge, 1/4" NPT Fitting $154.00 VMW-140-B-G-N07 With Bracket, Gauge, 1/4" Push to Connect Fitting $71.00 VMW-140-B-G-N09 With Bracket, Gauge, 5/16" Push to Connect Fitting $71.00 VMW-140-G-N01 With Gauge, 1/8" NPT Fitting $151.00

Model: 0 to -101kPa, Piping: NPT 1/8, M5 Female, Output: PNP Open Collector 2 Outputs, Display Unit: Fixed SI Unit, Lead Wire: Lead Wire w/Connector & Connector Cover, Bracket/Panel Mount Adapter: None, Operating Manual/Certificate: Operating Manual, Booklet, Made to Order: M12 4-pin Prewired Connector

One-touch fitting ARJ310-01 ARJ310-N01 ARJ310F-01-04 ARJ310F-01-06 ARJ310F-N01-03 ARJ310F-N01-07 R 1/8, M5 x 0.8 NPT 1/8, M5 x 0.8 R 1/8, M5 x 0.8 NPT 1/8, M5 x 0.8 Note) M5 x 0.8 female thread is cut inside the pipe.

ARJ310F-01-04 ARJ310F-01-06 ARJ310F-N01-03 ARJ310F-N01-07 R1/8, M5 x 0.8 NPT1/8, M5 x 0.8 Rc 1/8 Symbol NPT 1/8 4 One-touch fitting R1/8, M5 x 0.8 2 1 6 One-touch fitting 5/32" One-touch fitting NPT1/8, M5 x 0.8 1/4" One-touch fitting M5 x 0.8 female thread is cut inside the pipe.

KFG2H0122-N01 KFG2H0122-N02 KFG2H0325-N01 KFG2H0325-N02 KFG2H0704-N01 KFG2H0704-N02 KFG2H0906-N01 KFG2H0906-N02 KFG2H0906-N03 KFG2H1163-N02 KFG2H1163-N03 KFG2H1163-N04 KFG2H1395-N02 KFG2H1395-N03 KFG2H1395-N04 KQ2 16.2 19.4 16.2 19.4 17.9 21.1 20.1 22.3 23.6 25.3 25.6 27.1 27.1 27.2 28.7 1/8 1/4 1/8 1/4 1/8 1/4 1/8 1/4 3/8 1/4 3/8 1/2 1/4 3/8 1/2 12 14 12 14 12 14 19.4 23.8 19.4 23.8 21.1

Description Material Note 1 Body A Zinc alloy 2 Handle Brass Electroless nickel plated 3 Body B Brass Electroless nickel plated 4 Needle Brass Electroless nickel plated 5 Needle guide Brass Electroless nickel plated (1) 6 Seat ring Brass Zinc chromate plated (3) Meter-out Steel (2) 7 Lock nut Black zinc chromate plated Meter-in 8 U seal HNBR 9 O-ring NBR 10 O-ring NBR 11 O-ring NBR 12 01

B B B B B N.O.: Black B Dimensions B B N.C.: Gray O O S S M5 x 0.8 1/8 1/4 Barb fitting Applicable tubing: T0604 10 one-touch fitting Width across flats 17 Width across flats 14 Model Standard specifications Optional specifications Square type pressure gauge Digital pressure switch Round type pressure gauge Round type pressure gauge (with color zone) H J H H J H J J P1 P2 A B C E F G J K

MRQ L r b a = K + mL2 K: The moment of inertia around the center of gravity of the load K = m r2 12 a2 + b2 = m In case of 4. Round plate 2 4. Round plate (Including column) Position of rotational axis: Passing through the center axis 9. Gear transmission (A) (B) No. of teeth = a 1. Find the moment of inertia B for the rotation of shaft (B). 2.

) the conditions under which the workpiece will not drop are n x F > mg and therefore, F F mg F > n x m x g With a as the safety margin, F is determined as follows: a x mg F = n x MHZ MHF Multiples of Gripping Force by Workpiece Mass MHL Number of fingers: When n = 2 SMC performs calculations allowing for impacts which occur during normal transfer, etc., using a safety margin of a = 4.

B B B B B N.O.: Black Dimensions B B B N.C.: Gray O S O S 1/8 1/4 10 One-touch fitting Barb fitting Applicable tubing: T0604 M5 x 0.8 Width across flats 14 Width across flats 17 Model Standard specifications Optional specifications Square type pressure gauge Digital pressure gauge Round type pressure gauge P1 P2 A B Note) C D E G J F K H J H J H J AWM20/AWD20 28 27.8 1/8, 1/4 1/8 M28 x 1

B B B B B N.O.: Black Dimensions B B B N.C.: Gray O S O S 1/8 1/4 10 One-touch fitting Barb fitting Applicable tubing: T0604 M5 x 0.8 Width across flats 14 Width across flats 17 Model Standard specifications Optional specifications Square type pressure gauge Digital pressure gauge Round type pressure gauge P1 P2 A B Note) C D E G J F K H J H J H J AWM20/AWD20 28 27.8 1/8, 1/4 1/8 M28 x 1

ZP2-16UCL ZP (10, 13, 16) U ZP (10, 13, 16) C ZP (10, 13, 16) B ZP (10, 16) D ZPT2-A5, A6 ZPT2-B5, B6 B01, N01 T01 P. 72 P. 73 ZP (20, 25, 32) U ZP (20, 25, 32) C ZP (20, 25, 32) B ZP25D ZP2-B25J ZP2-B30J ZP2-25UCL ZP2-32UCL ZPT3-A6, A8 ZPT3-B5, B6, B8 B01, N01 T01 P. 72 P. 73 ZP (40, 50) U ZP (40, 50) C ZP (40, 50) B ZP40D ZPT4-A6, A8 ZPT4-B6, B8 B01, N01 T01 ZP2-40UCL ZP2-50UCL P. 72 P

Trace the arrow mark from the point A at an ambient temperature 86F (30C) to obtain the intersection B on the curved line for the relative humidity 60%. 2. Trace the arrow mark from the intersection B to obtain the intersection D on the pressure characteristic line for 102psi (0.7 MPa). 3. Trace the arrow mark from the intersection D to obtain the intersection E. 4.

T.T. 60 Push button (Mushroom) VM220-02-30R/B/G/Y VM230-02-30R/B/G/Y JIS Symbol 2 port Panel mounting hole 3 port EXH port (3 port only) 0.5 MPa supply 4.9 mm P.T. 52 N F.O.F. 2-5.5 mounting hole 1.6 mm O.T. 6.5 mm T.T. 5-6-23 Series VM200 Series VM200 Push button (Extended) VM220-02-32R/B/G/Y VM230-02-32R/B/G/Y JIS Symbol 2 port 3 port Panel mounting hole EXH port (3 port only) 0.5 MPa

If B is turned ON in 2. state, the output is turned OFF. If either A or B is turned ON, cylinder is actuated.

8370: JIS B 8361: JIS B 9960-1: 1 ) JIS B 8433-1993: 2) : : : 1. 2. 3. 1. 2. 3. 4

The set values for OUT1 are displayed in auto-preset mode as follows: Normal output Reversed output P_1 = A-(A-B)/4 n_1 = B+(A-B)/4 A = Max. pressure H_1 = (A-B)/2 H_1 = (A-B)/2 B = Min. pressure The set values of OUT2 become as follows "_", i.e. "P_2", "n_2", "H_2".