SMC Corporation of America
Elite Part Number Search
Search Results "ISE20-P-P-N01-Y"

Output Specification: P (PNP Open Collector 1 Output), Unit Specification: P (w/Unit Selection Function, Initial Value psi), Piping Specification: N01 (NPT 1/8), Option 1: w/o Lead Wire, Option 2: D (Panel Mount Adapter + Front Protection Cover)

Output Specification: P (PNP Open Collector 1 Output), Unit Specification: P (w/Unit Selection Function, Initial Value psi), Piping Specification: N01 (NPT 1/8), Option 1: w/o Lead Wire, Option 2: A1 (Bracket A, Vertical Mounting), Option 3: K (Operation Manual, Calibration Certificate)

Output Specification: P (PNP Open Collector 1 Output), Unit Specification: P (w/Unit Selection Function, Initial Value psi), Piping Specification: N01 (NPT 1/8), Option 1: w/o Lead Wire, Option 2: D (Panel Mount Adapter + Front Protection Cover), Option 3: K (Operation Manual, Calibration Certificate)

Output Specification: P (PNP Open Collector 1 Output), Unit Specification: P (w/Unit Selection Function, Initial Value psi), Piping Specification: N01 (NPT 1/8), Option 1: L (Lead Wire w/Connector, 2m)

Output Specification: P (PNP Open Collector 1 Output), Unit Specification: P (w/Unit Selection Function, Initial Value psi), Piping Specification: N01 (NPT 1/8), Option 1: L (Lead Wire w/Connector, 2m), Option 2: A2 (Bracket B, Horizontal Mounting)

Output Specification: P (PNP Open Collector 1 Output), Unit Specification: P (w/Unit Selection Function, Initial Value psi), Piping Specification: N01 (NPT 1/8), Option 1: L (Lead Wire w/Connector, 2m), Option 2: A1 (Bracket A, Vertical Mounting), Option 3: T (w/o Operation Manual, Calibration Certificate)

Output Specification: P (PNP Open Collector 1 Output), Unit Specification: P (w/Unit Selection Function, Initial Value psi), Piping Specification: N01 (NPT 1/8), Option 1: L (Lead Wire w/Connector, 2m), Option 2: B (Panel Mount Adapter), Option 3: K (Operation Manual, Calibration Certificate)

Output Specification: P (PNP Open Collector 1 Output), Unit Specification: P (w/Unit Selection Function, Initial Value psi), Piping Specification: N01 (NPT 1/8), Option 1: w/o Lead Wire, Option 2: None, Option 3: K (Operation Manual, Calibration Certificate)

Output Specification: P (PNP Open Collector 1 Output), Unit Specification: P (w/Unit Selection Function, Initial Value psi), Piping Specification: N01 (NPT 1/8), Option 1: L (Lead Wire w/Connector, 2m), Option 2: A2 (Bracket B, Horizontal Mounting), Option 3: T (w/o Operation Manual, Calibration Certificate)

Output Specification: P (PNP Open Collector 1 Output), Unit Specification: P (w/Unit Selection Function, Initial Value psi), Piping Specification: N01 (NPT 1/8), Option 1: w/o Lead Wire, Option 2: A2 (Bracket B, Horizontal Mounting), Option 3: K (Operation Manual, Calibration Certificate)

Output Specification: P (PNP Open Collector 1 Output), Unit Specification: P (w/Unit Selection Function, Initial Value psi), Piping Specification: N01 (NPT 1/8), Option 1: w/o Lead Wire, Option 2: None, Option 3: T (w/o Operation Manual, Calibration Certificate)

Output Specification: PNP Open Collector 1 Output, Unit Specification: w/Unit Selection Function, Piping Specification: M5 Female Thread, Option 1: w/o Lead Wire, Option 2: None, Option 3: w/o Operation Manual, w/o Calibration Certificate

Output Specification: PNP Open Collector 1 Output, Unit Specification: w/Unit Selection Function, Piping Specification: R 1/8, Option 1: w/o Lead Wire, Option 2: None, Option 3: w/o Operation Manual, w/o Calibration Certificate

Output Specification: P (PNP Open Collector 1 Output), Unit Specification: w/Unit Selection Function, Piping Specification: M5 (M5 Female Thread), Option 1: w/o Lead Wire, Option 2: None, Option 3: Y (w/o Operation Manual, w/o Calibration Certificate)

Output Specification: P (PNP Open Collector 1 Output), Unit Specification: w/Unit Selection Function, Piping Specification: 01 (R 1/8), Option 1: w/o Lead Wire, Option 2: None, Option 3: Y (w/o Operation Manual, w/o Calibration Certificate)

Model no. of NPT thread is AN101-N01 and AN110-N01. It can operate in temperatures between 10 to 150C if there is no risk of the moisture in the air freezing.

-X30 IR1010G33-4-01 G33-P4-N01-X30 IR1020G33-10-01 G33-P10-N01-X30 011/84 Rc NNPT FG 00.0050.2MPa 10.010.4MPa 20.010.8MPa PRECI SI O N REG U LATO R I R101BG M AX.

End plate ass'y 1 pc. 2500 3000 A B 146 Return to Menu Specialty Regulators NARM Series Regulator for Manifold NARM2500, 3000 P Dimensions Symbol A B C D E F G H I J K L M N O P Model NARM2500 .24 .67 1.73 2.20 1.65 4.98 2.28 1.77 .67 .83 1.50 1.65 1.14 1.89 2.68 1.32 (6) (17) (44) (56) (42) (126.5) (58) (45) (17) (21) (38) (42) (29) (48) (68) (33.5) NARM3000 .28 .83 2.13 2.68 2.17 6.04

G46 P10 N02 G36 P4 N01 G46 P4 N02 1348110A B Regulating pressure range Bracket 0.05 to 0.85MPa 0.05 to 0.30MPa 0 1 ARX20 Nil F ARX21 Nil F Thread type G Pressure gauge Rc NPT G Nil N F ARX20N ARX21N P Port size Panel nut 1/8 1/4 01 02 Option combination numbers Panel nut is also included with B.