Applicable tubing M01 3.18/2 Barb fittings (6/4) Barb fittings 4/2.5 M02 Stations Note) The outside and inside diameters of the applicable tubing are indicated for the barb fitting. 02 03 2 stations 3 stations D side U side Station 3 2 1 20 20 stations Note) Maximum of 20 stations Electrical entry Grommet/Plug lead C How to Order Valves S070 M 5 B G 32 Port size Symbol 32 40 Connection
M Series 13 Connection type M F B Male thread Female thread With barb fitting Port size variation Socket/Plug designation Male/Female thread type Barb fitting type S P Symbol 07 09 11 13 Symbol 01 02 03 04 G02 Socket Plug Thread size R, Rc 1/8 R, Rc 1/4 R, Rc 3/8 R, Rc 1/2 G1/4 Hose I.D. 1/4" 5/16" 3/8" 1/2" Construction No. 1 Description Material Plug Description Material Socket Note Nickel
Applicable bore size Dd9 L1 L2 m d Drill through Included split pin Included flat washer Clevis Knuckle 2 x d Dd9 CDP-2A 40 10 0.040 0.076 46 38 4 3 3 x 18 L Polished round 10 L1 L2 m L1 L2 m CDP-3A 50 40, 50, 63 12 0.050 0.093 55.5 47.5 4 3 3 x 18 L Polished round 12 2 x d Dd9 CDP-4A 63 16 0.050 0.093 71 61 5 4 4 x 25 L Polished round 16 L1 L2 m CDP-5A 80 18 0.050 0.093 76.5 66.5 5 4
M Series 13 Connection type M F B Male thread Female thread With barb fitting Port size variation Socket/Plug designation Male/Female thread type Barb fitting type S P Symbol 07 09 11 13 Symbol 01 02 03 04 G02 Socket Plug Thread size R, Rc 1/8 R, Rc 1/4 R, Rc 3/8 R, Rc 1/2 G1/4 Hose I.D. 1/4" 5/16" 3/8" 1/2" Construction No. 1 Description Material Plug Description Material Socket Note Nickel
Do not use a cable longer than 30 m. When using it as an IO-Link device, do not use a cable longer than 20 m. Wire the DC (-) line (blue) as close as possible to the power supply.
plug connector With lead wire Note 5) M 0 Without exhaust port 3 For manifold M-type plug connector Without connector Note 5) Silencer exhaust (Individual exhaust) MO No distinction Exhaust direction 1 Note 4) All with light and surge suppressor.
Clevis Pivot Bracket Pin (For CM2E(V)) Trunnion Nut/Material: Carbon steel (mm) (mm) H Material: Carbon steel B d D m m L2 C D t t L1 d Part no. Applicable bore size B C D d H TN-020B 20 26 28 25.5 M20 x 1.5 10 TN-032B 25, 32 32 34 31.5 M26 x 1.5 10 TN-040B 40 41 45 40.5 M32 x 2 10 Part no.
Series 2 3 4 Class 2 Class 3 Class 4 OUT port size Symbol 01 02 Port size 1/8 (6A) Stations 2 3 4 5 n Uside D side 1/4 (8A) Material All IN ports are 3/8.
Box 3385 Al-Amir Majed Street, Jeddah-21471, Saudi Arabia TEL: 02-6761574 FAX: 02-6708173 15-18-21
VT/O317-G(-02) VT/O317-GS(-02) VT/O317-H(-02) VT/O317-HS(-02) VT/O317-C(-02) VT/O317-CS(-02) VT/O317-T(-02) VT/O317-TS(-02) VT/O317-TZ(-02) VT/O317-D(-02) VT/O317-DS(-02) VT/O317-DZ(-02) Coil no. PVT317-001GBPVT317-G PVT317-001GB-L06 PVT317-G-06 PVT317-001CBPVT317-C Coil assembly with terminal part no.
3 (R) port 3 1 (R) (P) 7.4 3 (13) M plug connector (M) L plug connector: 10-VQD1151-L-M5 M plug connector: 10-VQD1151-M-M5 5 5 5.5 2(B) 4(A) Direct manual override Lead wire length 300 mm 27 Indicator light 17.6 5.5 12 11.2 3 3(R) 9 2-3.5 mounting hole 10.9 9.1 5.5 33.5 28.5 37 38 1(P) 1(P) 4-M5 x 0.8 13 L plug connector (L) (P, A, B, R port) 49 50.5 M plug connector (M) 634 4 port direct
2 Port for Steam Dimensions (mm) 1in = 25.4mm Grommet: G Conduit: C Q Approx. 300 F D Approx. 280 D Q F C G (PF) 1/2 C R R E E B A H 2-P Port size 2-P A B H 2-M Port size 2-M Thread depth N L L K K Conduit terminal: T F (Q) 34 25 U R C G (PF) 1/2 E B A H D 2-P Port size (S) 2-M L K N.C.
size 2-P Port size 2-M, thread depth N 2-M L L K K N.C. dimensions (mm) Grommet: G Conduit: C DIN terminal: D Conduit terminal: T P Port size Rc A B C D E F H K L M N Model Note) U Q V R Q R Q R S Q R S 83 22 23 45 44 43 58 40.5 46.5 99 43 66 13.5 28 64 31 6.5 12.5 28 14 12.8 M4 4.5 1/8 VCL21 86 22 23 46 44 44 58 41.5 46.5 99 44 66 18 36 67 31 8.5 12.5 28 18 12.8 M4 6 1/4 99 24 25 56.5 46
C37 Series 200 Symbol Port size PB 300 SUS M5 01 02 M5 1/8 (6A) 1/4 (8A) Thread type Nil F N Rc G NPT Piping to 3 Port Valve N.O. Port Caution Socket Electricity 1. Surge voltage A high voltage which is momentarily generated in the shut-off unit by shutting off the power. Cover Others 1. Material NBR: Nitrile rubber FKM: Fluoro rubber = FPM Trade names: Viton, Dai-El, etc.
M L2 Pressure range Option 3 Symbol Description ISE70 0 to 1 MPa ISE71 0 to 1.6 MPa Symbol Description Nil Operation manual Y None K Operation manual + Calibration certificate Piping specification Symbol Description 02 Rc1/4 N02 NPT1/4 F02 G1/4*1 T Calibration certificate Option 2 Symbol Description Nil None *1 ISO 1179-1 compliant Output specification*1 A Bracket A (Interchangeable with
ZS-10-5A-50 1 pc. 6 1A 36 VJ10 ZP 2 m (For 110 VAC) 2.5 m Lead wire length 6 Nil 3A 36 VJ10 SP 3 m 0.6 m 30 50 3 m 5 m ZCUK The asterisk () denotes the symbol for assembly. AMJ AMV Ejector System/Recommended Model (The models below will have shorter deliveries.)
Load factor: ((Load weight x 9.8) /Theoretical force) x 100% Note) 2 position single, 4/2 5/3 (A/B R1/R2) Conditions Base mounted Series CJ2 Series CM2 Series MB/CA1 TO604 x 1 m Tube x Length SQ1000 Speed controller AS3001F-06 Silencer AN110-01 Tube x Length T0604 x 1 m T1075 x 1 m T1209 x 1 m Speed controller AS4001F-10 AS3001F-06 SQ2000 Silencer AN200-02 2-3-1 2 Series SQ1000/2000 Precautions
VSA4320, VSA4420 Applicable valve Manifold weight general equation M = 0.66n + 0.75 (kg) n: Station VVSA430N Dimensions (mm) n L L2 256 L1 214 2 stations 326 284 3 stations Pilot hole 396 354 4 stations 466 424 5 stations 70n + 116 70n + 74 n stations VSA4130, VSA4230 VSA4330, VSA4430 Applicable valve 4-10.5 mounting hole Manifold weight general equation M = 0.87n + 0.95 (kg) n: Station
F(mm) Port B min. port size Weight (g) L1 L2 L3 L4 L5 L6 P Q1 Q2 M KM12-04-02-6 6 17 89 110 99 125 108 139 40 67 75 84 96 100 117 1 4 4 10 18 29.5 19.5 29 10.6 16 6 12 KM12-04-02-10 10 KM12-06-02-6 6 KM12-06-02-10 10 KM12-08-03-6 6 KM12-08-03-10 10 61.5 47 1 4 6 17 10 19.5 31.5 21.5 31 13 17 7.5 13.5 73 55 3 8 8 19 11.5 22.5 35.5 24 34.5 15.5 18.5 9 14.7 86 63 Series KM One-touch Fittings
A1 + 2 (Stroke) L2 + Stroke L3 Flange Style Without auto switch With auto switch Bore size (mm) Stroke range (mm) FD FT FV FX FZ L1 L2 M A B A B 64 40 5 to 50 40 74 50 5.5 8 54 62 72 17 7 40 74 50 75,100 66.5 40.5 10 to 50 50 76.5 50.5 6.6 9 67 76 89 18 8 50 50.5 76.5 75,100 68 42 10 to 50 63 78 52 9 9 80 92 108 18 8 60 78 52 75,100 For details about the rod end nut and accessory brackets