Status (7): TEMP READY signal output continues since the temperature is now back within the Out Time range of 200 sec even though it was temporarily outside the Low range. Status (8): TEMP READY signal turns OFF when 200 sec has passed after the temperature rises above the High range. TEMP READY alarm (AL12) is simultaneously activated.

Reed switch Solid state switch Relay, PLC 100 V, 200 V Yes Connector Terminal conduit DIN terminal Grommet 12 V 2-wire 24 V PLC Relay, PLC 100 V, 200 V Diagnostic indication (2-color indication) 3-wire (NPN) 3-wire (PNP) 5 V, 12 V IC circuit Grommet 2-wire 12 V Connector IC circuit 3-wire (NPN) 2-wire Terminal conduit 5 V, 12 V Relay, PLC Yes 24 V 12 V 3-wire (NPN) 3-wire (PNP)

Specifications ISA2-G1 ISA2-G5 ISA2-H1 ISA2-H5 Model Detection distance Fluid Operating pressure range Recommended detection nozzle 0.01 to 0.25 mm 0.03 to 0.50 mm Dry air (filtered to 5 m) 30 to 200 kPa 1.5 5 or less 8 or less 12 or less 50 to 200 kPa 2.0 10 or less 15 or less 22 or less 50 kPa 100 kPa 200 kPa Supply pressure Consumption flow rate L/min (ANR) 12 to 24 VDC 10%, Ripple (p-p

Without light SY100-61-1 With light Rated voltage Voltage symbol Part number 24 VDC 24 V SY100-61-3-05 12 VDC 12 V SY100-61-3-06 100 VAC 100 V SY100-61-2-01 200 VAC 200 V SY100-61-2-02 110 VAC 110 V SY100-61-2-03 220 VAC 220 V SY100-61-2-04 Without light SY100-82-1 Caution With light Rated voltage Voltage symbol Part number 24 VDC 24 VN SY100-82-3-05 12 VDC 12 VN SY100-82-3-06 100

Model 1 Port size A B C D E Applicable model Y110-M5-A M5 x 0.8 11.2 19 12 14 8 AC10-A, AC10B-A Y210-l01-A 1/8 14.6 41.8 32 28 19 AC20-B, AC20B-B AC20C-B Y210-l02-A 1/4 Y310-l01-A 1/8 14.6 52.7 38.7 30 19 AC25-B, AC25B-B AC25C-B, AC30C-B Y310-l02-A 1/4 Y410-l02-A 1/4 18.6 62 44 36 24 AC40-B, AC40B-B AC40C-B Y410-l03-A 3/8 Y510-l02-A 1/4 18.6 66 46 44 24 AC40-06-B, AC40B-06-B AC40C-06-B Y510

Size: 10 3 mounting holes with the marks are for tightening the actuator and not to be used for external mounting. 3 x M3 x 0.5 (Depth 6) 24 Chamfer (Rotation range is stated on page 54.) A port B port 29 9h9 0 0.036 4g7 0.004 0.016 0.5 2 x M3 x 0.5 9 24 14 29 3.6 3 9.5 9.5 1 18.5 19.8 35 67 2 15 When D-M9m is used *1.

Mounting side Closed C B A A Open D Open E F F Mounting side MHL2-25DZ-X86/X86A MHL2-25D Z-X86/X86A 1 2 200 200 160 160 Gripping force [N] Gripping force [N] Pressure 0.6 MPa Pressure 0.6 MPa 0.5 MPa 120 120 0.5 MPa 0.4 MPa 0.4 MPa 80 80 0.3 MPa 0.3 MPa Closed F (Fingers closed) 40 40 0 0 40 80 120 160 200 0 0 40 80 120 160 200 [mm] Model A B C D E F Weight [g] MHL2-25DZ-X86(A) 9 106 128

160 180 200 0.1 0 40 60 80 100 120 140 160 180 200 20 20 Overhang L (mm) Overhang L (mm) Graph (21) Stroke: Up to 200 stroke Graph (17) Stroke: Up to 200 stroke 10 20 10 20 2 3 4 5 2 3 4 5 Weight W (kg) Weight W (kg) 40 40 32 32 1 1 0.5 0.4 0.3 0.2 0.5 0.4 0.3 0.2 25 20 25 20 0.1 0.1 100 120 140 160 180 200 0 40 60 80 100 120 140 160 180 200 0 40 60 80 20 20 Overhang L (mm) Overhang L (mm

VVQ1000 J I 1 Plug-in Unit M A N I F O L D T Y P E H O W T O O R D E R C O N N E C T O R S W I T C H T Y P E/V O LTA G E (S O L I D S TAT E: 12~24 VDC) Without lead wire (connector 1pc, socket 4pcs) .ZS-20-A With lead wire .ZS-20-5A-50 14 NPN/1 setting, three revolution adjustment 15 NPN/1 setting, 200 0 adjustment 16 NPN/2 setting, three revolution adjustment 17 NPN/2 setting, 200 0 adjustment

Next, the viscosity of 15 mPas and the discharge rate of 200 l/min in the required specification example are converted to the discharge rate for fresh water. Since 48% of the fresh water discharge rate is equivalent to 200 ml/min in the required specifications, 200 ml/min 0.48 = approximately 420 ml/min, indicating that a discharge rate of 420 ml/min is required for fresh water. 3.

VAC (50 Hz) *5 Single-phase/Three-phase: 200/220 VAC (60 Hz) Three-phase: 200 VAC (50 Hz) Three-phase: 200/220 VAC (60 Hz) Single-phase 200 V 810/940 810/940 Power consumption [W] Electric specifications 50/60 Hz *6 Three-phase 200 V 850/1070 850/1070 1450/1890 2000/2500 Single-phase 200 V 4.3/4.7 4.3/4.7 Operating current [A] Refrigerant R407C (HFC) IDF F 50/60 Hz *6 Three-phase 200

CXS15 CXS20 CXS25 CXS32 Model 120 150 200 175 150 125 120 110 200 175 150 125 120 110 200 175 150 125 120 110 125 120 110 150 125 110 100 90 80 Stroke SS ZZ Z 175 210 282 257 232 207 202 192 272 247 222 197 192 182 270 245 220 195 190 180 185 180 170 205 180 165 155 145 135 Symbol Made to Order 192 229 312 287 262 237 232 222 296 271 246 221 216 206 294 269 244 219 214 204 204 199 189 222

Refer to page 178 for part numbers. 100/115 MR-C10A1 Mitsubishi Electric Corporation HC-PQ13 100 200/230 MR-C10A 100/115 SGDE-01BP 100 SGME-01BF12 Yaskawa Electric Corporation 200/230 SGDE-01AP SGME-01AF12 169 24 Series LG1H21 Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com

Optional specifications Note 2) With barb fitting B With drain guide B Metal bowl B 85 123 166 166 200 200 276 292 293 Metal bowl with level gauge Model B V AC10 AC20 AC25 AC30 AC40 AC40-06 AC50 AC55 AC60 161 161 195 195 272 287 288 160 160 194 194 271 286 287 186 186 220 220 296 312 313 38 38 45 45 45 45 45 4 F.R.L.

Basic mass 0.90 (Foot style 32) Additional mass 0.09/50 st Cylinder stroke 200 (st) 0.90 + 0.09 x 200/50 = 1.26 kg CX MQ RHC Mounting Bracket Part No.

Basic mass 0.90 (Foot style 32) Additional mass 0.09/50 st Cylinder stroke 200 (st) 0.90 + 0.09 x 200/50 = 1.26 kg CX MQ RHC Mounting Bracket Part No.

Bore size (mm) Maximum stroke Standard stroke (mm) 32 700 25, 50, 75, 100, 125, 150, 175, 200, 250, 300, 350, 400, 450, 500 40 800 25, 50, 75, 100, 125, 150, 175, 200, 250, 300, 350, 400, 450, 500 50 1200 25, 50, 75, 100, 125, 150, 175, 200, 250, 300, 350, 400, 450, 500, 600 63 1200 25, 50, 75, 100, 125, 150, 175, 200, 250, 300, 350, 400, 450, 500, 600 80 1400 25, 50, 75, 100, 125, 150, 175

B54 V V V Grommet Relay, PLC No 200 V or less A64 B64 V V Terminal conduit Yes 2-wire 24 V 12 V A33C A33 PLC 100 V, 200 V A34C A34 DIN terminal A44C A44 Relay, PLC Diagnostic indication (2-color indication) Grommet A59W B59W V V Water resistant type auto switches can be mounted on the above models, but in such case SMC cannot guarantee water resistance.

Nil E Yes Without light, with surge voltage suppressor Seal Metal seal Rubber seal 0 1 Coil voltage Function 1 2 3 Stations 1 2 3 4 5 6 100 VAC (50/60 Hz) 200 VAC (50/60 Hz) 110 VAC (50/60 Hz) 220 VAC (50/60 Hz) 24 VDC 12 VDC D side U side Standard type (1 W) Low wattage type (0.5 W) External pilot Nil Y R (1) (2) Applicable to DC sepecifications.