SMC Corporation of America
Elite Part Number Search
Search Results "JMDBF63TN-400-W"

N.O. type 0.1 MPa N.C. type 0.15 Mpa The supply pressure is insufficient. 243 Drain Separator for Vacuum Series AMJ Construction AMJ3000, 4000 AMJ5000 OUT IN IN OUT y r w t w y e r e The numbers are the same as the "Construction" of the Best Pneumatics No.4 Series AMJ. *BLUE links will lead to purchase pages. Replacement Parts Description Note Material Part no.

N.O. type 0.1 MPa N.C. type 0.15 Mpa The supply pressure is insufficient. 243 Drain Separator for Vacuum Series AMJ Construction AMJ3000, 4000 AMJ5000 OUT IN IN OUT y r w t w y e r e The numbers are the same as the "Construction" of the Best Pneumatics No.4 Series AMJ. *BLUE links will lead to purchase pages. Replacement Parts Description Note Material Part no.

-107No.JXC-OMT0001CN-C 1. 1.1 LEY/LEYG LEY16/LEYG16 LEY25/LEYG25 LEY32/LEYG32 LEY40/LEYG40 A B C A B C A B C A B C [mm] 10 5 2.5 12 6 3 16 8 4 16 8 4 [mm] 300 300 300 400 400 400 500 500 500 500 500 500 mm/s 500 250 125 500 250 125 500 250 125 300 150 75 [mm/s] () 15 8 4 18 9 5 24 12 6 24 12 6 [mm/s] () 22 12 6 26 13 7 34 17 9 34 17 9 1.2 LEFS LEFS16 LEFS25 A B H A B [mm] 10 5 20

W L In case the product is installed on the ceiling, regard the mounting bolt pitch as L. W L Mounting hole W Intermediate support mounting hole L L Distance between Load and Supports Mounting hole 140 130 25 120 CY3B CY3R 110 100 CY1S 90 4. When a 25 mm adjustment bolt is selected, the mounting holes will be hidden behind it. Adjust the adjustment bolt after the cylinder is installed.

200 500 0 0 100 300 400 200 500 Flow rate [L/min(ANR)] Flow rate [L/min (ANR)] IW215 Flow rate characteristics IW222 Flow rate characteristics Supply pressure: 0.7 MPa 0.5 0.45 0.4 0.35 0.3 0.25 0.2 0.15 0.1 0.05 0 0 100 300 400 200 600 500 Supply pressure: 0.5 MPa 0.25 0.2 Set pressure [MPa] Set pressure [MPa] 0.15 0.1 IP 0.05 IW IW 0 0 100 300 400 200 500 Flow rate [L/min(ANR)] Flow rate

(IEC 60417-5032-1) How to see the serial number W Z 001 December 2018 W Z 001 Year Symbol Remarks Month Symbol Remarks Serial no. 2018 W Repeated from A to Z in alphabetic al order 1 o Repeated from O to Z in alphabetical order, with O for January and Z for December 2019 X 2 P 2020 y 3 Q Fig. 1-1 Position of the product label HRS Series 1.4 Product Label 1-3 HRX-OM-W032 Chapter 1 Safety Instructions

Bore size System Average speed [mm/s] MB, CA2 series Pressure 0.5 MPa, Load ratio 50%, Stroke 500 mm 40 50 63 80 100 1000 900 800 700 600 500 400 300 200 100 0 Vertically upward Horizontal A 1000 900 800 700 600 500 400 300 200 100 0 B 1000 900 800 700 600 500 400 300 200 100 0 C Bore size System Average speed [mm/s] CS1/CS2 series Pressure 0.5 MPa, Load ratio 50%, Stroke 300 mm 125 140 160

IY W Lead screw is securely locked on the opposite side of the motor.

Tank capacity (l) Tc [s] = L W Obtain the tank capacity V. Select tank from table below.

, 300, 400 Panel mount All models applicable Different P port location (On handle side) Note that 1(P) port of VH600 is located on handle side as standard.

Dynamic moment Me3 L2 We W = 1/3 14.7 (50 + 27) 103 Review Me3. = 0.38 [Nm] 3 = Me3/Me3 max = 0.38/3 = 0.13 Guide central axis A Me1 W We Me1 = 1/3 We (L1 + B) 103 = 1/3 14.7 (50 + 48) 103 L1 B = 0.48 [Nm] 4 = Me1 /Me1 max = 0.48/3 = 0.16 Review Me1.

Note) Refer to page 568 for How to Order Pilot Valve Assembly. 564 VQ1000/2000 10211021-VQ2000 Plug-in Unit: Main Parts/Replacement Parts Metal seal Rubber seal e q w e q w 1021-VQ2101 (B) 2 (A) 4 1021-VQ2100 (B) 2 (A) 4 r r 3 (R2) 1 (P) 5 (R1) 3 (R2) 1 (P) 5 (R1) e q w e q w 1021-VQ2200 1021-VQ2201 (B) 2 (A) 4 (B) 2 (A) 4 3 (R2) 1 (P) 5 (R1) 3 (R2) 1 (P) 5 (R1) r r e q w e q w 1021-VQ2300

Note) Refer to page 568 for How to Order Pilot Valve Assembly. 564 VQ1000/2000 10211021-VQ2000 Plug-in Unit: Main Parts/Replacement Parts Metal seal Rubber seal e q w e q w 1021-VQ2101 (B) 2 (A) 4 1021-VQ2100 (B) 2 (A) 4 r r 3 (R2) 1 (P) 5 (R1) 3 (R2) 1 (P) 5 (R1) e q w e q w 1021-VQ2200 1021-VQ2201 (B) 2 (A) 4 (B) 2 (A) 4 3 (R2) 1 (P) 5 (R1) 3 (R2) 1 (P) 5 (R1) r r e q w e q w 1021-VQ2300

, 175, 200, 250, 300, 350, 400 400 67 25, 50, 75, 100, 125, 150, 175, 200, 250, 300, 350, 400 400 80 25, 50, 75, 100, 125, 150, 175, 200, 250, 300, 350, 400, 450, 500 500 85 25, 50, 75, 100, 125, 150, 175, 200, 250, 300, 350, 400, 450, 500 500 100 25, 50, 75, 100, 125, 150, 175, 200, 250, 300, 350, 400, 450, 500 500 Precautions Theoretical Output Be sure to read this before handling the products

MB 32 10% 30% 50% 300 70% Stroke mm AS2201F -01-08 AS2200-01 200 100 70% 50% 30% 10% 0 400 MB 40 300 Stroke mm AS2201F -02-08 AS2200-02 200 100 0 ANA1 -C10 T0806 400 MB 50 300 Stroke mm AS3201F -02-08 AS3000-02 200 100 0 400 MB 63 300 Stroke mm AS4000-03 200 100 0 Solenoid valve Silencer Tubing Speed controller 200 300 400 500 600 700 800 900 1000 1100 1200 Speed at the end mm/s Applicable

Contents 20 CBG1N20-PS Set of the nos. @5, @6, @7, @8 and grease pack 20 CBG1N20-PS-W Set of the nos. @5, @6, @7, @8 and grease pack CBG1lN Rubber bumper type CBG1lN Rubber bumper type 25 CBG1N25-PS 32 CBG1N32-PS 40 CBG1N40-PS 25 CBG1N25-PS-W 32 CBG1N32-PS-W 40 CBG1N40-PS-W Order seal kit in accordance with the bore size. * The seal kit includes a grease pack (10 g).

0.3 135 119 147 T 0.5 101 89 111 0.7 84 74 91 REA Foot: L Rod flange: Head flange: 0.3 301 267 330 F G L, F 0.5 231 207 253 REB W W W 0.7 193 172 212 REC 0.3 144 126 156 CY CY G 0.5 109 94 118 0.7 90 78 97 CX Foot: L Rod flange: Head flange: 0.3 433 386 476 F G MQ L, F 0.5 334 297 367 W W W RHC 0.7 281 250 309 0.3 210 185 229 RZQ G 0.5 160 141 175 0.7 134 117 129 D-X 1231 Series CS2Y Construction

W L In case the product is installed on the ceiling, regard the mounting bolt pitch as L. W L W Mounting hole Intermediate support mounting hole L L Distance between load and supports Mounting hole 140 130 25 120 110 100 90 4. When a 25 mm adjustment bolt is selected, the mounting holes will be hidden behind it. Adjust the adjustment bolt after the cylinder is installed.