Size: 32, Motor Mounting: Top Mounting Position, Motor Type: Step Motor, Servo/24 VDC, Lead: LEY25, 6; LEY32, 8, Stroke: 350mm, Motor: w/o Lock, Rod End Thread: Rod End Male Thread, 1 Rod End Nut Included, Mounting: Foot, Actuator Cable Length: 5m, Controller Type (LEC, JXC): JXC91, EtherNet/IPâ„¢ Direct Input Type, I/O Cable Length for LEC: w/o Cable, Controller Mounting: Rail Mounting,

Size: 32, Motor Mounting: Top Mounting Position, Motor Type: Step Motor, Servo/24 VDC, Lead: LEY25, 6; LEY32, 8, Stroke: 100mm, Motor: w/Lock, Rod End Thread: Rod End Female Thread, Mounting: Ends Tapped (Standard), Actuator Cable Length: 5m, Controller Type (LEC, JXC): JXC91, EtherNet/IPâ„¢ Direct Input Type, I/O Cable Length for LEC: w/o Cable, Controller Mounting: Rail Mounting, Communication

Size: 25, Motor Mounting: Top Mounting Position, Motor Type: Step Motor, Servo/24 VDC, Lead: LEY25, 6; LEY32, 8, Stroke: 200mm, Motor: w/o Lock, Rod End Thread: Rod End Female Thread, Mounting: Rod Flange, Actuator Cable Length: 5m, Controller Type (LEC, JXC): JXC91, EtherNet/IPâ„¢ Direct Input Type, I/O Cable Length for LEC: w/o Cable, Controller Mounting: Rail Mounting, Communication Plug

Size: 32, Motor Mounting: In-line Type, Motor Type: Step Motor, Servo/24 VDC, Lead: LEY25, 3; LEY32, 4, Stroke: 150mm, Motor: w/Lock, Rod End Thread: Rod End Male Thread, 1 Rod End Nut Included, Mounting: Ends Tapped (Standard), Actuator Cable Length: 5m, Controller Type (LEC, JXC): JXC91, EtherNet/IPâ„¢ Direct Input Type, I/O Cable Length for LEC: w/o Cable, Controller Mounting: Rail Mounting

Size: 25, Motor Mounting: Top Mounting Position, Motor Type: Step Motor, Servo/24 VDC, Lead: LEY25, 3; LEY32, 4, Stroke: 30mm, Motor: w/o Lock, Rod End Thread: Rod End Female Thread, Mounting: Ends Tapped (Standard), Actuator Cable Length: 5m, Controller Type (LEC, JXC): JXC91, EtherNet/IPâ„¢ Direct Input Type, I/O Cable Length for LEC: w/o Cable, Controller Mounting: Rail Mounting, Communication

Size: 32, Motor Mounting: Top Mounting Position, Motor Type: Step Motor, Servo/24 VDC, Lead: LEY25, 6; LEY32, 8, Stroke: 50mm, Motor: w/Lock, Rod End Thread: Rod End Male Thread, 1 Rod End Nut Included, Mounting: Ends Tapped (Standard), Actuator Cable Length: 5m, Controller Type (LEC, JXC): JXC91, EtherNet/IPâ„¢ Direct Input Type, I/O Cable Length for LEC: w/o Cable, Controller Mounting:

The rod type electric actuator LEY series has various body sizes with thrust equivalent to 16, 25, and 32 bore size. Direct or bracket mountings are available in three directions or types. Thrust, speed and positioning * can be managed with the use of an optional controller. Possible applications include transfer, opening and shutting, pressing, pushing, and press-fitting.Enclosure: IP65

The rod type electric actuator LEY series has various body sizes with thrust equivalent to 16, 25, and 32 bore size. Direct or bracket mountings are available in three directions or types. Thrust, speed and positioning * can be managed with the use of an optional controller. Possible applications include transfer, opening and shutting, pressing, pushing, and press-fitting.Enclosure: IP65

The rod type electric actuator LEY series has various body sizes with thrust equivalent to 16, 25, and 32 bore size. Direct or bracket mountings are available in three directions or types. Thrust, speed and positioning * can be managed with the use of an optional controller. Possible applications include transfer, opening and shutting, pressing, pushing, and press-fitting.Enclosure: IP65

EX245-DX1 2 . 7-3 X0 X1 X2 X3 X4 X5 X6 X7 2 Bit 1 Bit 3 Bit 5 Bit 7 Bit 9 Bit 11 Bit 13 Bit 15 4 Bit 0 Bit 2 Bit 4 Bit 6 Bit 8 Bit 10 Bit 12 Bit 14 48 No.EX-OMW0014CN-A 7.5. LED EX245-DX1 LED(16 )(015) 015 OFF OFF ON ON ON . 7-2 EX245-DX1 LED 49 No.EX-OMW0014CN-A 7.6. EX245-DX1 8M12(5 ,) (n+1) (n) FE/ / . 7-3 EX245-DX1 50 No.EX-OMW0014CN-A 8.

EX245-DX1 2Byte Table 11-3 X0 X1 X2 X3 X4 X5 X6 X7 2 Bit 1 Bit 3 Bit 5 Bit 7 Bit 9 Bit 11 Bit 13 Bit 15 4 Bit 0 Bit 2 Bit 4 Bit 6 Bit 8 Bit 10 Bit 12 Bit 14 72 No.EX##-OMY0006CN 11.5. LED EX245-DX1 LED 0 15 OFF ON Fig. 11-2 EX245-DX1 LED 73 No.EX##-OMY0006CN 11.6.

/ 64 points 128 points /128 points 4 words / 4 words 8 words / 8 words 16 words / 16 words Communication speed 156k / 625k / 2.5M / 5M / 10Mbps Communication method Broadcast Polling System Synchronization system Frame synchronous communication Encoding method NRZI Transmission system Bus system (EIA RS485 compliant) Communication format HDLC compliant Error control system CRC (X16+X12+X5

input points/ number of output points 4 words / 4 words 8 words / 8 words 16 words / 16 words Communication speed 156k / 625k / 2.5M / 5M / 10Mbps Communication method Broadcast Polling System Synchronization system Frame synchronous communication Encoding method NRZI Transmission system Bus system (EIA RS485 compliant) Communication format HDLC compliant Error control system CRC (X16+X12+X5

of 4 stations extended cyclic 8 times stations (Input 896 point 108word / Output 896 point 108word) Communication speed 156k/625k/2.5M/5M/10Mbps Communication method Broadcast Polling System Synchronization system Frame synchronous communication Encoding method NRZI Transmission system Bus system (EIA RS485 compliant) Communication format HDLC compliant Error control system CRC(X16+X12+X5

Table. 7-3 Digital input allocation and the process data Connector position Connector designation X0 X1 X2 X3 X4 X5 X6 X7 Pin 2 Bit 1 Bit 3 Bit 5 Bit 7 Bit 9 Bit 11 Bit 13 Bit 15 Input Pin 4 Bit 0 Bit 2 Bit 4 Bit 6 Bit 8 Bit 10 Bit 12 Bit 14 -41No.EX##-OMU0020-A 7.5.

Table. 7-3 Digital input allocation and the process data Connector position Connector designation X0 X1 X2 X3 X4 X5 X6 X7 Input Pin 2 Bit 1 Bit 3 Bit 5 Bit 7 Bit 9 Bit 11 Bit 13 Bit 15 Pin 4 Bit 0 Bit 2 Bit 4 Bit 6 Bit 8 Bit 10 Bit 12 Bit 14 48 No.EX-OMW0011-B 7.5.

800) 526-7661 Parallel Run LTees 3/8 7/16 1/4 5/16 5/16 1/4 5/16 1/4 8 T1-L1-1 T4-L4-4 T3-L3-3 T2-L2-2 Parallel Run Reducing LTees 3/8 5/16 5/16 5/16 3/4 15/16 5/16 5/16 5/16 5/16 5/16 5/16 1/4 1/4 MEM 27/32 5/8 5/8 3/4 9 RT3-2L-2 RT3-2L-3 RT4-3L-4 RT1-3L-1 RT3-1L-1 RT2-3L-2 1 11/16 Crosses 1/2 15/16 5/16 5/16 11/16 15/16 MEM 1/4 27/32 1 1 33/64 5/8 15/16 3/8 11/16 1 1/8 1/4 5/8 27/32 10 X5

MHW2-40D 2140 5 3.70 40 MHW2-40D1 2270 Symbol Specifications/Description Heat resistance Fluororubber seal Without magnet EPDM for seals, Fluorine grease Fluorine grease MHW2-50D 5100 -X4 -X5 -X50 -X53 -X63 -X79 -X79A 4 8.27 50 MHW2-50D1 5350 Note 1) At the pressure of 0.5 MPa Note 2) Except auto switch Refer to How to Select the Applicable Model on page 700 Refer to pages 700 and 701 for

MHF Symbol Specifications/Description Heat resistance (100C) Fluororubber seal Without magnet EPDM for seals, Fluorine grease Fluorine grease MHL -X4 -X5 -X50 -X53 -X63 -X79 -X79A -X81A Refer to How to Select the Applicable Model on page 700. Refer to pages 700 and 701 for the details on effective holding force and allowable overhanging distance.

With grease needle 3 Oil-proof 1 Cylinder bore X5 F 2 D 1 L D 1 F L MHK 2 MHK Cylinder bore X39 Finger material Dust cover material Finger material Action Action The packing class has been revised to adopt oil-proof materials for use in an environment with splashing of cutting oil, etc. Lubrication from grease needle to interior is possible.