Rated Flow Range: 11 (1 to 100 L/min), Flow Adjustment Valve: None (Straight), Port Size: N2 (NPT1/4), Output Specification: B (Out 1: PNP; Out 2: PNP), Lead Wire: W (Lead Wire w/Connector + Rubber Cover for Connector), Unit Specification: Unit Selection Function, Bracket/Panel Mount Adapter: R (Bracket, w/o Flow Adjustment Valve)
Rated Flow Range: 11 (1 to 100 L/min), Flow Adjustment Valve: None (Straight), Port Size: N2 (NPT1/4), Output Specification: L2 (Out 1: IO-Link or NPN/PNP, Out 2: NPN, PNP, or Input), Lead Wire: Lead Wire w/Connector, Unit Specification: Unit Selection Function, Bracket/Panel Mount Adapter: R (Bracket, w/o Flow Adjustment Valve), Calibration Certificate: None, Made to Order: X731 (Compatible
Rated Flow Range: 11 (1 to 100 L/min), Flow Adjustment Valve: None (Straight), Port Size: N2 (NPT1/4), Output Specification: B (Out 1: PNP; Out 2: PNP), Lead Wire: Lead Wire w/Connector, Unit Specification: Unit Selection Function, Bracket/Panel Mount Adapter: R (Bracket, w/o Flow Adjustment Valve)
Rated Flow Range: 11 (1 to 100 L/min), Flow Adjustment Valve: None (Straight), Port Size: N2 (NPT1/4), Output Specification: L (Out 1: IO-Link or NPN/PNP), Lead Wire: W (Lead Wire w/Connector + Rubber Cover for Connector), Unit Specification: Unit Selection Function, Bracket/Panel Mount Adapter: R (Bracket, w/o Flow Adjustment Valve)
Rated Flow Range: 11 (1 to 100 L/min), Flow Adjustment Valve: None (Straight), Port Size: N2 (NPT1/4), Output Specification: D (Out 1: NPN; Out 2: Analog 4 to 20 mA), Lead Wire: W (Lead Wire w/Connector + Rubber Cover for Connector), Unit Specification: M (SI Unit Only), Bracket/Panel Mount Adapter: R (Bracket, w/o Flow Adjustment Valve)
Size: 25, Motor Mounting Position: L (Left Side Parallel), Motor Type: T7 (AC Servo Motor, Absolute Encoder, 200 W), Lead: B [Size 16: 6mm, Size 25: 8mm (10mm, for Right and Left Side Parallel Type)], Stroke: 100mm, Motor Option: B (w/Lock), Cable Type: R (Robotic Cable, Flexible Cable), Cable Length: 2 (2m), Driver Type: N2 (LECSN2-T, 200~240V, Absolute, without Network Card), I/O Cable
Rated Control Flow Range: 11 (1 to 100 L/min), Port Size: N2 (1/4 NPT), Input/Output Specification: 1 (Input: Analog 1 to 5 V, Output 1:IO-Link/NPN/PNP, Output 2: Analog Output 1 to 5V or 0 to 10V), Wire Connector: With lead wire with connector (3 m/5 core), Unit Specification: Unit Specification, Bracket: R (Bracket (mounting position: Side)
Rated Flow Range: 11 (1 to 100 L/min), Flow Adjustment Valve: None (Straight), Port Size: N2 (NPT1/4), Output Specification: L4 (Out 1: IO-Link or NPN/PNP, Out 2: Analog 4 to 20 mA), Lead Wire: W (Lead Wire w/Connector + Rubber Cover for Connector), Unit Specification: Unit Selection Function, Bracket/Panel Mount Adapter: R (Bracket, w/o Flow Adjustment Valve)
Rated Control Flow Range: 11 (1 to 100 L/min), Port Size: N2 (1/4 NPT), Input/Output Specification: 2 (Input: Analog 4 to 20mA, Output 1:IO-Link/NPN/PNP, Output 2: Analog Output 4 to 20mA), Wire Connector: Q (M12-M12 lead wire with connector (3 m/5 core)), Unit Specification: M (SI units only), Bracket: R (Bracket (mounting position: Side), Operation Manual/Calibration Certificate: K (with
Rated Control Flow Range: 11 (1 to 100 L/min), Port Size: N2 (1/4 NPT), Input/Output Specification: 1 (Input: Analog 1 to 5 V, Output 1:IO-Link/NPN/PNP, Output 2: Analog Output 1 to 5V or 0 to 10V), Wire Connector: N (Without Lead Wire w/Function), Unit Specification: M (SI units only), Bracket: R (Bracket (mounting position: Side)
unit: IP40] IP40 IP40 IP40 IP65 Dry air, N2, Ar, CO2 Fluid Air, N2 Air, N2 Dry air, N2 Dry air, N2 Dry air, N2 Setting Digital Digital Digital Digital Digital Digital Rated flow range 1 to 10 L/min 5 to 50 L/min 10 to 100 L/min 20 to 200 L/min 50 to 500 L/min 0.2 to 10 L/min 0.5 to 25 L/min 1 to 50 L/min 2 to 100 L/min 30 to 3000 L/min 60 to 6000 L/min 120 to 12000 L/min 0 to 0.5 L/min 0
N1 1 N1 1 N1 1 N1 2 N2 2 N2 2 N2 2 N2 MHZ2-10 MHZ2-16 MHZ2-20 MHZ2-25 MHZ2-10 MHZ2-16 MHZ2-20 MHZ2-25 Specifications and dimensions other than the above are the same as the basic type (including narrow type).
Never mount a switch in a place that will be used as a scaffold during piping work. Damage may occur if subjected to an excessive load. Especially when the switch supports piping, do not apply a load of 15Nm or more to the metal part of the switch. 11. Provide a section of straight pipe of at least 8 times the pipe diameter in the piping before and after a switch.
Elgiloy is a registered trademark of Elgiloy Specialty Metals. Vespel is a registered trademark of DuPont. 3
DIGITAL FLOW SWITCH, DIGITAL FLOW SWITCH, F27, 48 lb
The type without the unit switching function will have a fixed SI unit (l/min, or l, m or m x 10). Output (OUT1) Indicator DOWN Button ( Button) Lights up when OUT1 is ON. UP Button ( Button) Use when decreasing a setting value. Use when increasing a setting value. MODE Button ( Button) SET Button ( Button) Use when changing a function. Use when selecting a function.
Part Number Description: CLAMP ARM Product Line: A Product Line Description: ACTUATOR Family Code: 549 Family Description: CKZN SLIM LINE CLAMP CYLINDER Class Code: N2 Part Code: 1 Reference Code: G This is a custom made item that is NOT returnableClick here to report information errorImage shown may not match exact part number, CLAMP ARM, ACTUATOR, CKZN SLIM LINE CLAMP
Part Number Description: STOPPER BOLT KIT Product Line: A Product Line Description: ACTUATOR Family Code: 549 Family Description: CKZN SLIM LINE CLAMP CYLINDER Class Code: N2 Part Code: 1 Reference Code: G This is a custom made item that is NOT returnableClick here to report information errorImage shown may not match exact part number, STOPPER BOLT KIT, ACTUATOR, CKZN
Part Number Description: STOPPER BOLT KIT Product Line: A Product Line Description: ACTUATOR Family Code: 549 Family Description: CKZN SLIM LINE CLAMP CYLINDER Class Code: N2 Part Code: 1 Reference Code: G This is a custom made item that is NOT returnableClick here to report information errorImage shown may not match exact part number, STOPPER BOLT KIT, ACTUATOR, CKZN
Part Number Description: CLAMP ARM Product Line: A Product Line Description: ACTUATOR Family Code: 549 Family Description: CKZN SLIM LINE CLAMP CYLINDER Class Code: N2 Part Code: 1 Reference Code: G This is a custom made item that is NOT returnableClick here to report information errorImage shown may not match exact part number, CLAMP ARM, ACTUATOR, CKZN SLIM LINE CLAMP