Please contact us for the latest version.sales@ocaire.com, CYL, HYDRAULIC, JPN SIMPLE SPL, OTHERS, CH HYDRAULIC CYLINDER, L4, 32MM CH SIMPLE SPL, .00000 lb
All series types are available with auto switch capability with the exception of the steel tube type., CYL, HYDRAULIC, JPN SIMPLE SPL, OTHERS, CH HYDRAULIC CYLINDER, L4, 32MM CH SIMPLE SPL, .00000 lb
Rated Distance Range: H (0.05 to 0.30mm), Piping Specifications: C (Supply Side: Rc 1/8, Detection Side: ø6 One-touch Fitting or ø4 One-touch Fitting in case of Rated Distance Range 0.01 to 0.03 mm), Output Specifications: N (NPN Output), Unit Specification: w/Unit Conversion Function, Stations: 1, Cable Option: L (Right Angle), Bracket Option: B (Bracket), Control Unit: L4 (w/Control Unit
Distance Range: H (0.05 to 0.30mm), Piping Specifications: C (Supply Side: Rc 1/8, Detection Side: ø6 One-touch Fitting or ø4 One-touch Fitting in case of Rated Distance Range 0.01 to 0.03 mm), Output Specifications: P (PNP Output), Unit Specification: w/Unit Conversion Function, Stations: 2, Cable Option: T (Centralized Lead Wired, w/Bracket), Bracket Option: B (Bracket), Control Unit: L4
Rated Distance Range: H (0.05 to 0.30mm), Piping Specifications: C (Supply Side: Rc 1/8, Detection Side: ø6 One-touch Fitting or ø4 One-touch Fitting in case of Rated Distance Range 0.01 to 0.03 mm), Output Specifications: P (PNP Output), Unit Specification: w/Unit Conversion Function, Stations: 1, Cable Option: Straight, Bracket Option: B (Bracket), Control Unit: L4 (w/Control Unit, Supply
Distance Range: H (0.05 to 0.30mm), Piping Specifications: C (Supply Side: Rc 1/8, Detection Side: ø6 One-touch Fitting or ø4 One-touch Fitting in case of Rated Distance Range 0.01 to 0.03 mm), Output Specifications: P (PNP Output), Unit Specification: w/Unit Conversion Function, Stations: 3, Cable Option: T (Centralized Lead Wired, w/Bracket), Bracket Option: B (Bracket), Control Unit: L4
Rated Distance Range: H (0.05 to 0.30mm), Piping Specifications: C (Supply Side: Rc 1/8, Detection Side: ø6 One-touch Fitting or ø4 One-touch Fitting in case of Rated Distance Range 0.01 to 0.03 mm), Output Specifications: P (PNP Output), Unit Specification: w/Unit Conversion Function, Stations: 4, Cable Option: L (Right Angle), Bracket Option: B (Bracket), Control Unit: L4 (w/Control Unit
Rated Distance Range: G (0.02 to 0.15mm), Piping Specifications: C (Supply Side: Rc 1/8, Detection Side: ø6 One-touch Fitting or ø4 One-touch Fitting in case of Rated Distance Range 0.01 to 0.03 mm), Output Specifications: P (PNP Output), Unit Specification: M (Fixed SI Unit), Stations: 1, Cable Option: Straight, Bracket Option: B (Bracket), Control Unit: L4 (w/Control Unit, Supply Port:
Rated Distance Range: F (0.01 to 0.03mm), Piping Specifications: F (Supply Side: G 1/8, Detection Side: G 1/8), Output Specifications: P (PNP Output), Unit Specification: w/Unit Conversion Function, Stations: 2, Cable Option: T (Centralized Lead Wired, w/Bracket), Bracket Option: B (Bracket), Control Unit: L4 (w/Control Unit, Supply Port: Left Side, With regulator, Square type pressure gauge
Rated Distance Range: G (0.02 to 0.15mm), Piping Specifications: C (Supply Side: Rc 1/8, Detection Side: ø6 One-touch Fitting or ø4 One-touch Fitting in case of Rated Distance Range 0.01 to 0.03 mm), Output Specifications: P (PNP Output), Unit Specification: M (Fixed SI Unit), Stations: 1, Cable Option: L (Right Angle), Bracket Option: B (Bracket), Control Unit: L4 (w/Control Unit, Supply
IO-Link 9.3 9.8 SI US1 US1 1 IO-Link SI US2 US2 P24 IO-Link IO-Link / / (Digital input ) SI US1 2 US1 / / (Digital output ) SI US1 3 US1 IO-Link / / 4 C/Q3 L-1 L+3 L4 LED 0, 2, 4, 6 IO-Link / LED 1, 3, 5, 7 (EX245-LB1) 2 P24 5 N24 5 84 No.EX-OMW0014CN-A Revision history A IO-Link EX245-LA1/LB1 [2021 8 ] 4-14-1, Sotokanda, Chiyoda-ku, Tokyo 101-0021 JAPAN Tel:
Rated Flow Range: 10 (0.1 to 10 L/min), Flow Adjustment Valve: S (With Flow Adjustment Valve, Straight), Port Size: N1 (NPT1/8), Output Specification: L4 (Out 1: IO-Link or NPN/PNP, Out 2: Analog 4 to 20 mA), Lead Wire: Q (w/M12 Conversion Lead Wire and Connector, 0.1m)
Please contact us for the latest version.sales@ocaire.com, LSA-75-1.5-L4 W/ 1 STROKE, ACTUATOR, GRIPPER, NC, 50MM GRIPPER, .00000 lb
SERIES C95 D I M E N S I O N S ( M M) C95 G U I D E U N I T S Diameter A B C D1 D2 D3 E2 E3 E4 F L0 L1 L2 32 12 12 74 m6 6.6 11 33 78 61 4 45 92 50 40 16 15 87 M6 6.6 11 38 84 69 18 55 112 58 50 20 19 104 M8 9 15 47 100 85 24 68 134 70 63 20 19 119 M8 9 15 57 105 100 20 80 148 85 80 25 22 148 M10 11 18 72 130 130 25 100 180 105 100 25 22 173 M10 11 18 89 150 150 30 120 206 13 Diameter L3L L4
L1 D L2 L3 L4 L5 L6 L8 Model Port size AS2000E-01 4.5 16 57 61.5 15.5 10 17 30 5 40 1/8 AS2000E-02 4.5 20 59 63.5 17 12 23 30 5 40 1/4 AS3000E-02, 03 5.5 26 69 76 20.6 13.25 25 45.5 5.25 56 1/4, 3/8 AS4000E 2-1/4 to 1/2 72 (Max. 80) Effective thread depth 6 15-9-42
Number of needle rotations Number of needle rotations Inlet pressure: 0.5 MPa Inlet pressure: 0.5 MPa Flow rate l/min (ANR) Flow rate l/min (ANR) Effective area (mm2) Effective area (mm2) AS ASP ASN Number of needle rotations Number of needle rotations AQ Dimensions ASV (Hexagon width across flats) (Hexagon width across flats) Applicable tubing O.D. d Applicable tubing O.D. d AK ASS ASR ASF L4
D L2 L3 L4 L5 L6 L7 L8 P d h T L1 Model Model ASS10 ASS100 ASS110 2 10 5 20 9 5 20 52 14 4 17 50 XT14-82-3-1 1 8 ASS30 ASS300 ASS310 3.2 12 6 30 12 6 26 73 23 5 16.5 63 XT14-105-5-1 1 4 3 8 , ASS500 ASS500 2.3 14 7 35 13 6 38 99 27 6 30.5 90 XT14-89-2-1 1 2 3 4 , ASS600 ASS600 3.2 14 7 65 14 6 46 116 31 6 26 112 XT14-85-2-1 3 4 1 , AS Meter-in Control Type Meter-out Control Type ASP Mounting
L1 L2 L3 L4 L5 L6 L7 L8 D Model Bore size ASS AS2000-01 AS2000-02 AS3000-02, 03 1 8 Rc Rc Rc , 40 40 56 30 30 45.5 5 5 5.25 17 23 25 10 11.5 13.2 15.5 17 20.6 54.5 56 68 50 51.5 61 16 20 26 4.5 4.5 5.5 1 4 1 4 ASR Effective thread depth 6 8 3 Dimensions: AS5000 ASF 2-1/4 to 1/2 2-M4 x 0.7 Effective thread depth 7 15-9-31
Description Material AS800 AS900 y u i JIS B 2401 P-7 JIS B 2401 P-7 AQ NBR O-ring u O-ring O-ring Spring NBR NBR Stainless steel JIS B 2401 P-12 JIS B 2401 G-50 14115 JIS B 2401 P-16 JIS B 2401 G-65 14124 JIS B 2401 P-48 JIS B 2401 P-38 NBR O-ring ASV i AK ASS Dimensions: AS420/500/600 Dimensions: AS800/900 ASR ASF 2-Port size 2-Port size Dimensions Dimensions L1 L2 L4 Min.
Rated Distance Range: H (0.05 to 0.30mm), Piping Specifications: C (Supply Side: Rc 1/8, Detection Side: ø6 One-touch Fitting or ø4 One-touch Fitting in case of Rated Distance Range 0.01 to 0.03 mm), Unit Specification: w/Unit Conversion Function, Stations: 2, Cable Option: T (Centralized Lead Wired, w/Bracket), Bracket Option: B (Bracket), Control Unit: L4 (w/Control Unit, Supply Port: Left