"n" pcs. Nil S n Stroke (mm) 12mm 16mm 20mm 25mm 2 pcs. 1 pc. "n" pcs.
175 185.5 9 154 164 187.5 198 10 170 180 200 210.5 L1 L2 L3 L4 31 Series VQZ Base Mounted Type Dimensions: VQZ300 VQZ300 (mm) VV3QZ35C Stations Port size (35) (5.5) 2-4.5 Mounting holes 42 (11) Grommet (G) N7T: One-touch fitting for 1/4" n-N7T, N9T, N11T, 02T 34 (7.5) (3) DIN rail clamp screw 23.5 N9T: One-touch fitting for 5/16" N11T: One-touch fitting for 3/8" 02T: 1/4 NPTF U side n A
Simple Specials System Please contact your local sales representative for more details. 2 *1 Soft Start-up Valve AV2000-A/3000-A/4000-A/5000-A Series 2(A) Symbol How to Order (P)1 3(R) AV 00 20 02 B B 1 D q w e r t y u i o A *1 CE compliant Electrical entry Grommet DIN terminal AC V DC V V V q Body size 20 30 40 50 Symbol Description w Thread type Nil Rc V V V V N NPT V V V V F G V V V V
Broken communicatio wire n monitoring o r time. coming 60 sec. off AL19 Communication error is generated.
Drain guide 1/4 Note 4) AFM30, 40 Rc NPT G Nil C AFM20 to 40 1/8 1/4 3/8 1/2 3/4 01 02 03 04 06 R Flow direction: Right to left AFM20 to 40 N Note 1) Float type auto drain (N.O.)
30.7 Brackets on both sides Brackets on both sides L8 x n + L17 x 2 L8 x n + L16 x 2 L8 x n + L25 x 2 L8 L8 1 Refer to page 618 for L8. 2 The above figure shows the manifold with controllers connected using two L-brackets and a threaded stud kit for manifold.
NPT thread Model Model 10-32 UNF M5 3/8 1/8 1/4 1/2 3/8 1/8 1/4 1/2 AKH04 AKH06 AKH08 AKH10 AKH12 AKH03 AKH07 AKH09 AKH11 AKH13 4 6 8 10 12 5/32 1/4 5/16 3/8 1/2 From One-touch fitting to male thread B Bushing type AKB 01 A 01 S With seal (Standard) Body size Port size 01 1/8 01 1/8 Thread type 02 1/4 02 1/4 03 3/8 Nil R 03 3/8 04 1/2 N NPT 04 1/2 Check valve free flow direction Female/Male
Example) AR30-03BG-NR-B-X425 Symbol Description Nq Body size 25 30 40 50 60 Symbol Description Nq Body size 20 25 30 40 50 60 Nw Pipe thread type Nil Rc N NPT F G + Nw Pipe thread type Nil Rc N NPT F G + 02 1/4 03 3/8 04 1/2 06 3/4 10 1 + Ne Port size 01 1/8 02 1/4 03 3/8 04 1/2 06 3/4 10 1 + Ne Port size Nil Without mounting option B*2 With bracket a Mounting Option *1 H With set nut (for
N) 99(4) 100(4) AC DC AC/DC 60 40 1 80 60 10(1) 60 40 40 60 Maximum Minimum 10 5(2) Note 1) Dew point: 10C or less Note 2) 50 cSt or less Note 3) D, E, N, P etc. in parentheses are option symbols.
SD (2) SU (2) W 5 VQ5000 D U D side mounting U side mounting Manifold 1 Plug-in unit Stations 02 2 stations Cylinder port 03 04 B CM Rc 3/8 Rc 1/2 Bottom ported Rc 1/2 Mixed 12 12 stations Note 1) When two or more symbols are specified, indicate them alphabetically.
-02/03 3 (Exhaust center) Rc 1/4: 17 VH302-02/03 VH312-02/03 2 (Position) 1 (P) 3 (R) 2 1 VH3 0.71 1/4, 3/8 VH320-02/03 VH330-02/03 3 (Closed center) Rc 3/8: 20 Exhaust center VH321-02/03 VH331-02/03 3 (Exhaust center) (A) 2 (B) 4 VH322-02/03 VH332-02/03 2 (Position) 12 3 4 VH400-02 to 06 VH410-02 to 06 3 (Closed center) 1 (P) 3 (R) Rc 1/4: 45 4 3 VH401-02 to 06 VH411-02 to 06 3 (Exhaust
3 (R) 4 3 3 (Exhaust center) VH301-02, 03 VH311-02, 03 Rc1/4: 17(0.9) Exhaust center 2 (Position) VH302-02, 03 VH312-02, 03 2 1 (A) 2 (B) 4 VH3 1/4, 3/8 0.71 3 (Closed center) VH320-02, 03 VH330-02, 03 Rc3/8: 20(1.1) 1 (P) 3 (R) 3 (Exhaust center) VH321-02, 03 VH331-02, 03 2 (Position) VH322-02, 03 VH332-02, 03 12 3 4 3 (Closed center) VH400-02 to 06 VH410-02 to 06 Rc1/4: 45(2.5) 4 3 3 (Exhaust
39.9 34.9 18.5 15 17 8 R 1/4 ASD430FG-02-08S 28.2 18.5 55 46.5 15.2 34.4 29.4 11 19.7 10 21 31 58 ASD430FG-02-10S 49.3 18.5 17 25.2 74 6 ASD530FG-02-06S 48.3 12.8 20.3 18.5 28.2 76 8 ASD530FG-02-08S 51.3 15.2 46.9 41.9 48.3 43.3 23 19.8 19 R 1/4 42.8 37.8 15.4 21 80 32.6 10 ASD530FG-02-10S 54.1 18.5 23.1 22 83 34.4 55.9 12 ASD530FG-02-12S 20.9 17 74 25.2 48.3 6 ASD530FG-03-06S 12.8 20.3 18.5
Port size N M5 U10/32 01 02 03 04 M5 x 0.8 10-32 UNF 1/8 1/4 3/8 1/2 Needle Valve/Flow Characteristics AS121FG AS131FG AS221FG-01 AS231FG-01 AS221FG-02 AS231FG-02 Inlet pressure: 0.5 MPa Inlet pressure: 0.5 MPa Inlet pressure: 0.5 MPa 07, 08, 09, 10, 11 05, 06, 07, 08, 09, 10 Flow rate (/min (ANR)) Flow rate (/min (ANR)) Flow rate (/min (ANR)) Effective area (mm2) Effective area (mm2) Effective
Stainless steel specification (SUS303) Port size Thread type M5 x 0.8 10-32UNF 1/8 1/4 3/8 1/2 M5 U10/32 01 02 03 04 Nil Metric thread (M5) Unified thread (10-32UNF) R(PT) NPT N Needle Valve/Flow Rate Characteristics AS121FG AS131FG AS221FG-01 AS231FG-01 AS221FG-02 AS231FG-02 07,08,09,10,11 05,06,07,08,09,10 05,06 01,03,04 03,04 AS321FG AS331FG AS421FG AS431FG 12,13 10,11 10,11,12 08,09 06,07
N X36A Left side port operation Right side port operation C-TYPE A-TYPE NAMUR interface 3 port/5 port A 3 port Port #4 on Coil side B 5 port Port #2 on Coil side C 3 port Port #2 on Coil side D 5 port Port #4 on Coil side Voltage 3 110VDC 5 24VDC Manual override B Locking type (Tool required) Thread type N NPT Thread size 02 1/4 Specifications 5-way solenoid valve configuration (for Double
Free flow Controlled flow Weight (g) Sonic conductance dm3/(sbar) Sonic conductance dm3/(sbar) Critical pressure ratio Critical pressure ratio Model Port size Flow rate (L/min (ANR)) Flow rate (L/min (ANR)) AS1000-M3 AS1000-M5 AS2000-01 AS2000-02 AS3000-02 AS3000-03 AS4000-02 AS4000-03 AS4000-04 AS5000-02 AS5000-03 AS5000-04 0.06 20 0.06 20 M3 x 0.5 4.7 0.15 0.22 80 0.25 90 M5 x 0.8 33 0.7
Port size Thread type Symbol Bore Size Nil N F Rc NPT G 1 5 10 20 30 3 50 60 75 100 01 1/8 02 1/4 04 1/2 03 3/8 Standard Specifications/Single Style (Standard Dew Point 20C [4F]) Standard dew point 20C (4F) Model IDG1 IDG5 IDG10 IDG20 IDG30 IDG50 IDG60 IDG75 IDG100 IDG3 IDG1 Fluid Compressed air Range of operating conditions Standard performance conditions Standard performance Inlet air