VQ Refer to table w for configuration. Refer to p.4.0-15 for coil only. Port size 01 02 03 1 8 1 4 3 8 Thread Rc(PT) NPTF G(PF) NPT Refer to table q for configuration.
N.O. 3(R) (P)1 3(R) (P)1 e t q r e t q r (A) (A) 2 2 u u 3 (R) 1 (P) 3 (R) 1 (P) w w y y Component Parts Replacement Parts Note Zinc die-casted Part no.
HRX-OM-M091-P Operation Manual Communication function Thermo chiller Air-Cooled Water-Cooled refrigerated type refrigerated type HRS012-A-10HRS012-W-10HRS018-A-10HRS018-W-10HRS012-A-20HRS012-W-20HRS018-A-20HRS018-W-20HRS024-A-20HRS024-W-20HRS030-A-20HRS030-W-20HRS040-A-20 HRS040-W-20HRS050-A-20HRS050-W-20HRS060-A-20HRS060-W-20Keep this manual available whenever necessary 2022 SMC CORPORATION
(Request)[STX] 01WLOC01 [ETX] [26h] (Response)[STX] 01[ACK] [ETX] [06h] Request message Response message Code Contents Code Contents 01 Slave Address 01 Slave Address W Request message to write [ACK] Normal response message LOC Key-lock setting [06h] BCC value 01 Read information (01All locked) [26h] BCC value 5.8 Command explanation HRSH Series 5-20 HRX-OM-Q033 Chapter 5 Simple communication
(Request)[STX] 01WLOC01 [ETX] [26h] (Response)[STX] 01[ACK] [ETX] [06h] Request message Response message Code Contents Code Contents 01 Slave Address 01 Slave Address W Request message to write [ACK] Normal response message LOC Key-lock setting [06h] BCC value 01 Read information (01All locked) [26h] BCC value 5.8 Command explanation HRS100/150 Series 5-20 HRX-OM-S010 Chapter 5 Simple communication
(g) n: Stations W = 30n + 50 W = 37n + 63 W = 61n + 101 W = 79n + 127 W = 100n + 151 Note) For more than 10 stations, supply pressure to P port on both sides and exhaust from EA and EB port on both sides.
(Request)[STX] 01WLOC01 [ETX] [26h] (Response)[STX] 01[ACK] [ETX] [06h] Request message Response message Code Contents Code Contents 01 Slave Address 01 Slave Address W Request message to write [ACK] Normal response message LOC Key-lock setting [06h] BCC value 01 Read information (01All locked) [26h] BCC value 5.8 Command explanation HRSH Series 5-20 HRX-OM-R028 Chapter 5 Simple communication
AC20C G36-10-01 GC3-10AS G36-2-01 GC3-2AS AD27 Y200 IS1000M-20 Model Description AC25C G36-10-01 GC3-10AS G36-2-01 GC3-2AS AC30C G36-10-01 GC3-10AS G36-2-01 GC3-2AS AC40C G46-10-02 GC3-10AS G46-2-02 GC3-2AS AC40C-06 G46-10-02 GC3-10AS G46-2-02 GC3-2AS Round Square embedded type 1.0MPa Note 1) Note 2) Pressure gauge Attachments Accessories Round Square embedded type N.O.
M plug connector 2 position double: VZS2250-M(Z)-01 3 position closed center: VZS2350-M(Z)-01 3 position exhaust center: VZS2450-M(Z)-01 3 position pressure center: VZS2550-M(Z)-01 DIN terminal 2 position double: VZS2250-D(Z)-01 3 position closed center: VZS2350-D(Z)-01 3 position exhaust center: VZS2450-D(Z)-01 3 position pressure center: VZS2550-D(Z)-01 Applicable cable O.D.: 3.5 to 7 MAX
(Request)[STX] 01WLOC01 [ETX] [26h] (Response)[STX] 01[ACK] [ETX] [06h] Request message Response message Code Contents Code Contents 01 Slave Address 01 Slave Address W Request message to write [ACK] Normal response message LOC Key-lock setting [06h] BCC value 01 Read information (01All locked) [26h] BCC value 5.8 Command explanation HRS090 Series 5-20 HRX-OM-T004 Chapter 5 Simple communication
X Port size) Speed controller System figure System Solenoid valve SYJ7l40-01 Rc(PT)1/8 (S = 12.6mm2) AN110-01 (S = 35mm2) 4 X 1/8 AS2301F-01-04 A 02 03 AS3301F-06 6 X 1/4 B q 02 03 AS3301F-08 SYJ7l40-02 Rc(PT)1/4 (S = 12.6mm2) 8 X 1/4 C AN200-02 (S = 35mm2) 02 03 AS3301F-10 10 X 1/4 D 12 X 1/4 12 X 1/2 AS4001F-12 w E 1.2-53 Series SYJ7000 How to Order Light and surge voltage suppressor
IS1000E-402 14 33 87 66 17.5 IS1000E-403 38 AC4000 IS1000E-404 12 IS1000E-406 34 50 87 66 17.5 H O W T O O R D E R P R E S S U R E S W I T C H *Without Yoke Clip.
C2SF-C C4SF-J C4SF-W C4SF-6 AD47-6 AD48-6 C4SF-6J C4SF-6W C4SF-2 AD47-2 AD48-2 C4SF-2J C4LF-8 AD47-8 AD48-8 C4LF-8J C2SF-C Drain AD27-C AD27-C C2SF-J C3SF-J C4SF-J Polycarbonate C2SF-J C3SF-J AF50, AF60 C3SF-W C4SF-W C3SF-W C2SF-CJ C2SF-CJ C3SF-6 C4SF-6 C2SF-6 C1SF-6 AD17-6 C1SF-2 AD17-2 C3SF-6 C2SF-6 C1SF-6 OUT IN C2SF-6C C2SF-6C AD37-6 AD47-6 AD27-6 AD37-6 AD17-6 AD27-6 AD38-6
C2SF-C C4SF-J C4SF-W C4SF-6 AD47-6 AD48-6 C4SF-6J C4SF-6W C4SF-2 AD47-2 AD48-2 C4SF-2J C4LF-8 AD47-8 AD48-8 C4LF-8J C2SF-C Drain AD27-C AD27-C C2SF-J C3SF-J C4SF-J Polycarbonate C2SF-J C3SF-J AF50, AF60 C3SF-W C4SF-W C3SF-W C2SF-CJ C2SF-CJ C3SF-6 C4SF-6 C2SF-6 C1SF-6 AD17-6 C1SF-2 AD17-2 C3SF-6 C2SF-6 C1SF-6 OUT IN C2SF-6C C2SF-6C AD37-6 AD47-6 AD27-6 AD37-6 AD17-6 AD27-6 AD38-6
Connector for unit (Plug) 6 y t y t EX600-DXlB EX600-DYlB EX600-DXlCl q w q w e q w er e y t y t y t EX600-DXlD EX600-DXlE EX600-DYlE EX600-DMlE EX600-DXlF EX600-DYlF EX600-DMlF Analog Unit q w e q w e No.
Symbol Size 01 R1/8 02 R1/4 03 R3/8 04 R1/2 Applicable tubing O.D.
= 29n + 21 W = 51n + 35 W = 63n + 64 W = 97n + 80 W = 139n + 550 Weight: W [g] Stations: n Note) Supply pressure to 1(P) ports and exhaust pressure from R ports on both sides for 10 stations or more (5 stations or more for the VF5000).
t e y u i u SI unit output polarity e Stations q Series 4 VQC4000 Nil N In the case of the 32-output SI unit Positive common Negative common Symbol 01 Stations Note 1 station w Manifold model Double wiring Note 1) i Option 1 Plug-in unit 12 01 12 stations 1 station Nil S K None Built-in silencer, Direct exhaust Note 1) Specified layout Note 2) (Available up to 24 solenoids) r Cylinder port
2 i r i t y w w e !0 !0 !2 !5 o !0 !4 q q y u !1 !3 r t !1 M5 type U10/32 type M5 type U10/32 type !1 y !2 u !4 !3 i !5 u e r r t w e o !0 i o q q t y !0 !2 w !
DC (17 mA), 0.95 W DC (40 mA) (4) Power consumption (Current) 12 VDC 0.4 W DC (34 mA), 0.95 W DC (80 mA) (4) (R1)5 1 (P) 3(R2) Note 1) Use dry air to prevent condensation when operating at low temperatures.