Magnet: Built-in, Mounting: Basic Style, Bore Size: Ø25, Stroke: 50mm, Cushion: Rubber Bumper, Rod Boot: None, Auto Switch: A93--Reed, DC Volt, AC Volt, LED, Horizontal, Lead Wire or Prewired Connector: 3m, Number: -
Magnet: Built-in, Mounting: Basic, Bore Size: 20mm, Stroke: 50mm, Rod End Nut: Female Thread, Auto Switch: A93--Reed, DC Volt, AC Volt, LED, Horizontal, 0.5M, Lead Wire or Prewired Connector: 3m, Number: -
Cylinder (Tube) Inner Diameter(φ): 12, Stroke(mm): 50, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Single Rods, Main Body Shape: Others, Additional Function: Standard / With rod detent function, Environment, Applications: Standard, Cushion: Without cushion, Operating Pressure(MPa): 0.07 to 1.0, Specification: -, Auto Switches: A93, Lead Wire Length(m):
Cylinder (Tube) Inner Diameter(φ): 20, Stroke(mm): 50, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Single Rods, Main Body Shape: Others, Additional Function: Standard / With rod detent function, Environment, Applications: Standard, Cushion: Without cushion, Operating Pressure(MPa): 0.05 to 1.0, Specification: -, Auto Switches: A93, Lead Wire Length(m):
Cylinder (Tube) Inner Diameter(φ): 12, Stroke(mm): 50, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Single Rods, Main Body Shape: Others, Additional Function: Standard / With rod detent function, Environment, Applications: Standard, Cushion: Without cushion, Operating Pressure(MPa): 0.07 to 1.0, Specification: -, Auto Switches: A93, Lead Wire Length(m):
Cylinder (Tube) Inner Diameter(φ): 40, Stroke(mm): 50, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Single Rods, Main Body Shape: Guided, Additional Function: Standard / With rod detent function, Environment, Applications: Standard, Operating Pressure(MPa): -, Cushion: Air cushion, Operating Pressure(MPa): 0.1 to 0.7, Specification: Without end lock (standard
Cylinder (Tube) Inner Diameter(φ): 20, Stroke(mm): 50, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Single Rods, Main Body Shape: Others, Additional Function: Standard, Environment, Applications: Standard, Operating Temperature(°C): 0~60, End Locking: No, Valves: No, Operating Pressure(MPa): 0.1~1.0, Specification: Built-in magnet, Auto Switches: A93, Lead
Magnet: Built-in, Mounting: Rod Flange, Bore Size: 32mm, Stroke: 50mm, Rod End Thread: Male Thread, Auto Switch: A93--Reed, DC Volt, AC Volt, LED, Horizontal, Lead Wire or Prewired Connector: 3m, Number: -, Auto Switch Mounting Bracket: -
Cylinder (Tube) Inner Diameter(φ): 16, Stroke(mm): 50, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Single Rods, Main Body Shape: Guided, Additional Function: High rigidity / high precision high class guide, Environment, Applications: Standard, Cushion: With bumper on both ends, Operating Pressure(MPa): 0.15 to 0.7, Specification: Built-in magnet, Port thread
Piston Material: Stainless Steel, Added Function: N/A, Rod Motion: Double Acting Single Rod, Operating Pressure Range(MPa): 0.3~16, Tube Material: Aluminum, Piston Speed(mm/sec): 8~100, Piston Packing Material: NBR, Stroke(mm): 50, Cushioning Mechanism: N/A, Operating Temperature Range(°C): -10~60, Support Type: Retainer Pin/Stopper Set, Standard: JIS Specifications, Nominal Pressure: 16MPa
Cylinder (Tube) Inner Diameter(φ): 6, Stroke(mm): 50, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Single Rods, Main Body Shape: Guided, Additional Function: Cylinder with functions of thrusting and boosting, Environment, Applications: Standard, Cushion: Rubber bumper at both ends, Operating Pressure(MPa): 0.15 to 0.7, Specification: Built-in magnet, Port
Cylinder (Tube) Inner Diameter(φ): 10, Stroke(mm): 50, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Single Rods, Main Body Shape: Guided, Additional Function: Cylinder with functions of thrusting and boosting, Environment, Applications: Standard, Cushion: Rubber bumper at both ends, Operating Pressure(MPa): 0.1 to 0.7, Specification: Built-in magnet, Port
Cylinder (Tube) Inner Diameter(φ): 15, Stroke(mm): 50, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Single Rods, Main Body Shape: Guided, Additional Function: Cylinder with functions of thrusting and boosting, Environment, Applications: Standard, Cushion: Rubber bumper at both ends, Operating Pressure(MPa): 0.1 to 0.7, Specification: Built-in magnet, Port
Cylinder (Tube) Inner Diameter(φ): 25, Stroke(mm): 50, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Single Rods, Main Body Shape: Guided, Additional Function: Cylinder with functions of thrusting and boosting, Environment, Applications: Standard, Cushion: Rubber bumper at both ends, Operating Pressure(MPa): 0.05 to 0.7, Specification: Built-in magnet, Port
Magnet: D (Built-in), Mounting: F (Rod Flange), Bore Size: 140mm, Port Thread: Rc, Stroke: 50mm, Rod Boot: None, Auto Switch: A93--Reed, DC Volt, AC Volt, LED, Horizontal, Lead Wire or Prewired Connector: L (3m)
Bore Size: 16mm, Stroke: 50mm, Auto Switch: A93--Reed, DC Volt, AC Volt, LED, Horizontal, 0.5M, Lead Wire or Prewired Connector: L (3m)
Bore Size: 20mm, Stroke: 50mm, Auto Switch: A93--Reed, DC Volt, AC Volt, LED, Horizontal, 0.5M, Lead Wire or Prewired Connector: L (3m)
Bore Size: 20mm, Port Thread: 12-25mm Bore: M Thread; 32-40mm Bore: Rc, Stroke: 50mm, End Lock: w/o End Lock, Rod End: Rod End Female Thread, Auto Switch: A93--Reed, DC Volt, AC Volt, LED, Horizontal, 0.5M, Lead Wire or Prewired Connector: L (3m)
Bore Size: 25mm, Symmetric Type: Standard, Stroke: 50mm, Adjuster: w/o Adjuster, Function: Standard, Auto Switch: A93--Reed, DC Volt, AC Volt, LED, Horizontal, 0.5M, Lead Wire or Prewired Connector: L (3m)
Bore Size: 25mm, Symmetric Type: L (Symmetric), Stroke: 50mm, Adjuster: w/o Adjuster, Function: Standard, Auto Switch: A93--Reed, DC Volt, AC Volt, LED, Horizontal, 0.5M, Lead Wire or Prewired Connector: L (3m)