Refer to 1.4 Product Label" and check the part number of the product. 200 S A 46 HRS Cooling capacity Option 2 200 20kW None Nill Fixed SI unit W*2 Cooling method A Air-cooled refrigeration *2Unit: MPa/ oC (degree Celsius) Option 1 Piping thread type None Nill Nil Rc Caster-adjuster foot installed A F G (Rc-G thread adapter set is included) Fluid fill port K*1 N NPT (Rc-NPT thread adapter
, 50 75, 100, 125, 150, 175, 200, 250, 300 300 Other intermediate strokes can be manufactured upon receipt of order.
Model XL-25-2 XL-40-2 XL-50-2 XL-63-2 XL-80-2 Rated voltage for heater 90 to 240 VAC Heater assembly quantity 1 1 1 1 H4 100C 100 V 200/40 200/50 400/100 600/150 Heater assembly quantity used Heater power W (Nominal value) Inrush/Power consumption (Option symbol, Operating voltage) 200 V 800/40 800/50 1600/100 2400/150 Heater assembly quantity 1 1 1 1 2 H5 120C 100 V 200/40 400/70 400/
Thrust energy E2 100 10 20 30 40 50 100 200 300 Fs Fs + mgs Fsmgs 400 500 Absorbed energy E W2 max.
HRZ Power supply 20 3-phase 200 VAC (50 Hz) 3-phase 200 to 230 VAC (60 Hz) HRZD Specifications HRW Model HRS100-Wl-20-l HRS150-Wl-20-l Cooling method Water-cooled refrigeration Refrigerant R410A (HFC) Refrigerant charge kg 1.23 1.33 Control method PID control Ambient temperature Note 1) C 2 to 45 HECR HEC Circulating fluid Note 2) Tap water, 15% ethylene glycol aqueous solution, Deionized
Mounting Bolt for C55 Model C D Mounting bolt Model C D Mounting bolt Model C D Mounting bolt C(D)55B20-5 -10 -15 -20 -25 -30 -35 -40 -45 -50 -60 -80 -100 -125 -150 C(D)55B25-5 -10 -15 -20 -25 -30 -35 -40 -45 -50 -60 -80 -100 -125 -150 C(D)55B50-5 -10 -15 -20 -25 -30 -35 -40 -45 -50 -60 -80 -100 -125 -150 C(D)55B63-5 -10 -15 -20 -25 -30 -35 -40 -45 -50 -60 -80 -100 -125 -150 C(D)55B32-5 -
KE [mm] Bore size A B D E F G H J K M N O P Q T V Y Z W Rc NPT G Rc NPT G 16 59.5 41.5 10 29 6 3 18 18 28 3.5 6.5 depth 4 M5 x 0.8 M5 x 0.8 M5 x 0.8 17 20 18 37 0 0 0 20 67 45 12 36 8 4 22 22 36 5.5 9 depth 7 1/8 1/8 M5 x 0.8 20 24 22 47 1.5 1.5 0 32 68 48 20 45 7.5 8 20 4.5 32 34 5.5 9 depth 7 1/8 1/8 1/8 20 36 20 14 40 80.5 52.5 25 52 8 10 28 5 41 40 5.5 9 depth 7 1/8 1/8 1/8 24.5
10 5 5 0 0 500 1500 2000 0 0 100 200 300 400 500 600 1000 Distance (mm) Distance (mm) Air purge: Yes Supply pressure: 0.1 MPa (7 L/min (ANR) per nozzle) Air purge: Yes Supply pressure: 0.05 MPa (3.5 L/min (ANR) per nozzle) 45 25 40 35 20 Discharge time (s) Discharge time (s) 60 Hz 30 15 25 1 Hz/60 Hz 20 1 Hz 10 15 Sensing DC Sensing DC 10 5 5 00 500 1000 1500 2000 00 500 1000 1500 2000 Distance
speed (mm/s) L unit 1000 1000 Air cushion 500 400 300 500 400 300 L unit Air cushion 200 200 1002 3 4 5 10 20 50 100 1 2 3 4 5 10 20 30 400 50 Caution Load weight (kg) Load weight (kg) 1.
300400500 1000 1500 0.05 0.5100 200 300400500 1000 1500 100 200 300400500 1000 1500 Piston speed (mm/s) Piston speed (mm/s) Piston speed (mm/s) Maximum Load Weight: MY1MW MY1MW/m3 MY1MW/m2 MY1MW/m1 30 100 200 20 40 50 100 10 30 50 20 40 4 5 30 MY1MW63 MY1MW63 MY1MW63 MY1MW63 3 Load weight (kg) Load weight (kg) Load weight (kg) 10 MY1MW63 MY1MW63 MY1MW63 MY1MW63 MY1MW63 MY1MW63 20 MY1MW50
MY1MW32 MY1MW32 5 4 0.5 0.4 MY1MW32 MY1MW32 MY1MW25 MY1MW25 3 MY1MW25 MY1MW25 0.3 1 MY1MW20 MY1MW20 MY1M20 MY1MW25 MY1MW25 2 0.2 MY1MW20 MY1MW20 MY1MW20 MY1MW20 0.5 MY1MW16 MY1MW16 MY1MW16 MY1MW16 0.4 1 0.1 MY1MW16 MY1MW16 0.3 0.2 100 200 300 400 500 1000 1500 0.05 0.5 100 200 300 400 500 1000 1500 100 200 300 400 500 1000 1500 Piston speed (mm/s) Piston speed (mm/s) Piston speed (mm/s)
200 Caution 1002 3 4 5 10 20 50 100 1 2 3 4 5 10 20 30 400 50 1.
Note 2) When the valve is a standard (dust-protected) specification, it is not compatible with 200 or 220 VAC.
Q P R O D U C T S Q Q Q Q Q Q 3 Q Q 3 Port 100/200/300 Series VQZ Base Mounted & Body Ported High speed and Long life. Response time Life VQZ100 10ms VQZ200 12ms 200 million cycles VQZ300 15ms Dispersion accuracy 2ms * Life: Metal seal type * Response time: Metal seal, single solenoid with light and surge voltage supressor.
(L/min [ANR]) 300 150 SUP = 0.5 MPa SUP = 0.5 MPa SUP = 0.4 MPa 200 SUP = 0.4 MPa 100 SUP = 0.3 MPa SUP = 0.3 MPa SUP = 0.2 MPa SUP = 0.2 MPa 100 50 0 5 0 0 10 0 10 15 20 25 20 30 40 50 Discharge rate (L/min) Discharge rate (L/min) PAF3413 Air Consumption (2 Hz) PAF5413 Air Consumption (1 Hz) 200 Air consumption (L/min [ANR]) Air consumption (L/min [ANR]) 300 150 200 100 SUP = 0.5 MPa SUP
(The lock-up cylinder can operate at 50 to 200 mm/s.)
200 to 220 VAC (60 Hz) IDF-S0090 IDF-S0091 IDF-S0092 Drain valve (A) Note) Includes wire with connector on the end.
D-J51: 5 ms or less Except D-J51 (1 mA or less at 100 VAC, 1.5 mA or less at 200 VAC), D-M5NW/M5PW/M5BW, D-F9BAL, D-P5DWL (1 mA or less at 24 VDC).
D-J51: 5 ms or less Except D-J51 (1 mA or less at 100 VAC, 1.5 mA or less at 200 VAC), D-M5NW/M5PW/M5BW, D-F9BAL, D-P5DWL (1 mA or less at 24 VDC).