SMC Corporation of America
Elite Part Number Search
Search Results "RZQD50TN-250-100"

300 500 1000 70 100 300 500 1000 70 100 300 500 1000 Stroke (mm) Stroke (mm) Stroke (mm) 2.

150 300 200 120 Consumption flow rate [L/min (ANR)] Consumption flow rate [L/min (ANR)] Consumption flow rate [L/min (ANR)] 250 100 160 ZP3 200 80 120/150 120 150 60 ZP3E 40/60/80 80 100 40 ZP2 40 50 20 ZP2V 0 0 0 0 0.05 0.1 0.15 0.2 0.25 0.3 0.35 0.4 0.45 Supply pressure (MPa) 0 0.05 0.1 0.15 0.2 0.25 0.3 0.35 0.4 0.45 Supply pressure (MPa) 0 0.05 0.1 0.15 0.2 0.25 0.3 0.35 0.4 0.45 Supply

Rubber bumper is standard equipment for long stroke type. 75, 100, 125, 150, 175, 200 75, 100, 125, 150, 175, 200, 250, 300 20 Action 5, 10, 15, 20, 25, 30, 35, 40, 45, 50 D Double acting 25 For "Manufacture of Intermediate Strokes", refer to page 7-4-5. Applicable Auto Switch/Refer to page 7-9-1 for further information on auto switches.

Standard Stroke Maximum manufacturable stroke (mm) Bore size (mm) Standard stroke (mm) 10 50, 100, 150, 200, 250, 300 500 15 50, 100, 150, 200, 250, 300, 350, 400, 450, 500 750 25 100, 150, 200, 250, 300, 350, 400, 450, 500, 550, 600 1200 The stroke is available in 1 mm increments with the maximum stroke as the upper limit.

Maximum manufacturable stroke (mm) Bore size (mm) Standard stroke (mm) 10 50, 100, 150, 200, 250, 300 500 15 50, 100, 150, 200, 250, 300, 350, 400, 450, 500 750 25 100, 150, 200, 250, 300, 350, 400, 450, 500, 550, 600 1200 The stroke is available in 1 mm increments with the maximum stroke as the upper limit. For a stroke in the standard stroke range, suffix the part number with -XB10.

Maximum manufacturable stroke (mm) Bore size (mm) Standard stroke (mm) 10 50, 100, 150, 200, 250, 300 500 15 50, 100, 150, 200, 250, 300, 350, 400, 450, 500 750 25 100, 150, 200, 250, 300, 350, 400, 450, 500, 550, 600 1200 The stroke is available in 1 mm increments with the maximum stroke as the upper limit. For a stroke in the standard stroke range, suffix the part number with -XB10.

Cylinder stroke (mm) Long stroke (mm) 35, 40, 45, 50, 75, 100 Bore size (mm) Standard stroke (mm) 5, 10, 15, 20, 25, 30 Action D Double acting 12, 16 75, 100, 125, 150, 175, 200 75, 100, 125, 150, 175, 200, 250, 300 20 5, 10, 15, 20, 25, 30, 35, 40, 45, 50 25 Applicable Auto Switches/Refer to p.5.3-2 for further information on auto switch.

Standard Stroke Maximum stroke available (mm) Bore size (mm) Standard stroke (mm) 10 50, 100, 150, 200, 250, 300 500 15 50, 100, 150, 200, 250, 300, 350, 400, 450, 500 750 25 100, 150, 200, 250, 300, 350, 400, 450, 500, 550, 600 1200 The stroke is available in 1 mm increments with the maximum stroke as the upper limit.

0 25 50 75 1.0 0 2 6 4 8 1.0 100 0 25 50 75 10 Input signal (%F.S.)

125 150 175 200 250 300 Reed switches: D-Z7, Z8 Solid state switches: D-Y5, Y6, Y7 Female threads Male threads 180 Single rod Double acting CQ2 200 Double rod New 180 and 200 Compact cylinder variations A wide range of 15 sizes from 12 to 200 Bore size (mm) Compact cylinder series 12 16 20 25 32 40 50 63 80 100 125 140 160 180 200 CQ2 Large bore CQ2 CQS Refer to N320 "CQ2" and CAT.E256-

260 287.5 298 16 266 276 300 310.5 17 282 292 312.5 323 18 298 308 337.5 348 19 314 324 350 360.5 12 202 212 237.5 248 13 218 228 250 260.5 14 234 244 275 285.5 7 122 132 162.5 173 8 138 148 175 185.5 9 154 164 187.5 198 10 170 180 200 210.5 11 186 196 225 235.5 4 74 84 112.5 123 5 90 100 125 135.5 6 106 116 137.5 148 L1 L2 L3 L4 1.12-21 VQZ1000/2000/3000 Body Ported Dimensions: VQZ3000

MPa) Operating pressure range 15 to 100 psi (100 kPa to 0.7 MPa) External pilot operating pressure range 2-position single 35 to 100 psi (0.25 to 0.7 MPa) Pilot pressure range 2-position double 35 to 100 psi (0.25 to 0.7 MPa) 3-position Based on IEC 60529 Note)Impact resistance: No malfunction occurred when tested in the axial direction and at the right angles to the main valve and armature

260.5 234 244 275 285.5 250 260 287.5 298 266 276 300 310.5 282 292 312.5 323 298 308 337.5 348 58 68 87.5 98 74 84 112.5 123 90 100 125 135.5 106 116 137.5 148 122 132 162.5 173 138 148 175 185.5 154 164 187.5 198 42 52 75 85.5 L1 L2 L3 L4 4-14-37 Base Mounted 38 Series VQZ100/200/300 Dimensions: VQZ300 VV3QZ35Stations Port size C Grommet (G) (35) (5.5) 2-4.5 mounting hole 43.5 (11) C6:

Mounting orientation is Upper direction Model Port size Rc(PT) 63 63 80 85 90 100 B C A INA-11-402 INA-11-403 INA-11-404 INA-11-405 INA-11-406 INA-11-407 1/4 141 164.5 170 180 230 251 15 15 15 20 22 22 3/8 1/4, 1/2 3/8, 3/4 3/4, Bracket dimensions Model Port size B C D E A 1 F 345 419.2 K 57 49.6 J 14 14 H 95 120 G 32.5 0 1 1 1 1 2 4, 1 2, 1 175 250 175 250 87.5 125 460 613 135 209 4, 3 ALD600

It can be used in the vacuum (up to 100 kPa) or low pressure line with 0.15 MPa or less.

, 150, 200 M5 x 0.8 12-CY3B10 10 500 50, 100, 150, 200, 250, 300 15 1000 12-CY3B15 50, 100, 150, 200, 250, 300, 350, 400, 450, 500 12-CY3B20 20 100, 150, 200, 250, 300, 350, 400, 450, 500, 600, 700, 800 Rc1/8 NPT1/8 G1/8 25 12-CY3B25 (Both sides) Non-lube 32 12-CY3B32 1300 Rc1/4 NPT1/4 G1/4 12-CY3B40 40 100, 150, 200, 250, 300, 350, 400, 450, 500, 600, 700, 800, 900, 1000 12-CY3B50 50 12

90 1 1/4 Short 0.57 to 1.67 17 34 PF2 160 140 1 1/2 Short 0.63 to 1.95 26 52 140 125 2 Middle 0.34 to 1.06 23 45 IF IF31-10 280 250 2 1/2 Middle 0.41 to 1.29 45 90 Data 250 220 3 Middle 0.26 to 0.81 40 80 550 480 4 Long 0.33 to 1.05 85 170 Long 1,000 870 5 0.37 to 1.24 150 300 Long 1,500 1,300 6 0.40 to 1.32 230 460 110 100 1 Short 1.00 to 3.05 18 36 160 140 1 1/4 Short 0.90 to 2.67 27 54

For each additional input block, add 21mm.) n: Stations (maximum 24 stations) n L L1 L2 L3 L4 1 55.5 178 200 210.5 2 66 188.5 212.5 223 3 76.5 199 225 235.5 4 87 209.5 237.5 248 5 97.5 220 250 260.5 6 108 230.5 250 260.5 7 118.5 241 262.5 273 8 129 251.5 275 285.5 9 139.5 262 287.5 298 10 150 272.5 300 310.2 11 160.5 283 312.5 323 12 171 293.5 325 335.5 13 181.5 304 325 335.5 14 192 314.5

Table 8.1-1 Quality criteria for clean water (tap water) Item Unit Criterion Circulating fluid Facility water pH (at 25 oC) 6.0 to 8.0 6.5 to 8.2 Electric conductance (at 25 oC) [S/cm] 100 to 300 100 to 800 Chloride ion [mg/L] 50 or less 200 or less Standard Sulphate ion [mg/L] 50 or less 200 or less item Acid consumption (at pH 4.8) [mg/L] 50 or less 100 or less Total hardness [mg/L] 70

, 300, 350, 400 450, 500 15 1000 750 25 32 200, 250, 300, 350, 400, 450 500, 600, 700, 800 2000 1500 Note) Intermediate strokes can be arranged in 1mm increments.