IDG75M IDG100M IDG3HM IDG5HM IDG10HM IDG20HM IDG30HM IDG50HM IDG60HM IDG75HM IDG100HM 25 50 100 200 300 500 600 750 1000 25 50 100 200 300 500 600 750 1000 IDG30LM IDG50LM IDG60LM IDG75LM IDG100LM 75 110 170 240 300 IDG60SM IDG75SM IDG100SM 50 100 150 Type V A regulator combined with the type M IDG3V IDG5V IDG10V IDG20V IDG30V IDG50V IDG60V IDG75V IDG100V IDG3HV IDG5HV IDG10HV IDG20HV IDG30HV
170 (6.00) 240 (8.48) 300 (10.59) IDG30LM IDG50LM IDG60LM IDG75LM IDG100LM 50 (1.77) 100 (3.53) 150 (5.30) IDG60SM IDG75SM IDG100SM V type A regulator combined with the M type 25 (0.88) 50 (1.77) 100 (3.53) 200 (7.06) 300 (10.59) 500 (17.66) 600 (21.19) 750 (26.49) 1000 (35.31) IDG3V IDG5V IDG10V IDG20V IDG30V IDG50V IDG60V IDG75V IDG100V 25 (0.88) 50 (1.77) 100 (3.53) 200 (7.06) 300 (10.59
Up to 700 80 7 RS Q G 25 25 1500 250 Up to 700 80 12 32 32 1500 250 Up to 1000 80 21 RS H A 40 40 1500 250 Up to 1000 80 33 50 50 1500 250 Up to 1200 RZQ 80 47 63 63 1500 250 Up to 1200 80 84 MI W S 80 80 1500 250 Up to 1400 80 127 100 100 1500 250 Up to 1500 80 196 CEP1 Note 1)The cylinder performance may not be as expected when stroke is shorter than recommended stroke (1 to 249 stroke
-0.016 -0.043 +0.043 0 -0.025 -0.064 40 40 36 M16 x 1.5 25 22 18 7 14 55 250 40 M20 x 1.5 30 27 22.4 9 19 60 255 -0.025 -0.064 +0.052 0 -0.020 -0.053 50 50 40 M20 x 1.5 30 27 22.4 9 19 60 280 46 M24 x 1.5 35 32 28 11 24 65 285 63 63 46 M24 x 1.5 35 32 28 11 24 70 327.5 55 M30 x 1.5 45 42 35.5 13 30 80 337.5 -0.030 -0.076 +0.062 0 -0.025 -0.064 80 80 55 M30 x 1.5 45 42 35.5 13 30 80 367.5
F A A Lr Lr = 200mm L X S 400 8 60 Table displacement (m) LXSH-150 Table displacement (m) Table displacement (m) 350 7 LXSH-150 LXSH-150 50 300 6 LXSH-125 LXSH-125 250 5 40 LXSH-125 LXSH-100 LXSH-100 200 4 30 LXSH-75 LXSH-100 LXSH-75 3 150 20 LXSH-50 LXSH-75 2 100 LXSH-50 LXSH-50 10 1 50 0 0 0 1 2 3 4 5 6 8 9 10 10 10 7 1 2 3 4 5 6 8 9 7 1 2 3 4 5 6 8 9 7 Weight (kg) Weight (kg) Weight (kg
Double acting, Single rod 25, 50, 75, 100, 125, 150 1/8 25, 50, 75, 100, 125, 150, 200 1/4 25, 50, 75, 100, 125, 150, 200, 250, 300 Suction Flow Rate of Vacuum Suction Type (Reference values) Specifications Bore size (mm) Item 20/25/32/40 2 Bore size Suction flow rate L/min (ANR) 20/25/32/40 1.5 MPa 1.0 MPa 0.05 MPa Without auto switch: 10C to 70C With auto switch: 10C to 60C (No freezing
Seal kit includes a grease pack (125 to 160: 40 g, 180 and 200: 50 g, 250 and 300: 60 g). Order with the following part number when only the grease pack is needed. Grease pack part no.: GR-S-010 (10 g), GR-S-020 (20 g) Kit no.
P N E U T / | A T I C T E C H N O L O G Y Average plston speed ln mm/s 150 200 250 300 400 0.15 0.2 0.25 0.3 0.4 0.36 0.46 0.6 0.72 1 1000 1 2.4 4 6.7 1 1 1 7 27 500 0.5 750 0.75 1.8 3 5 8.5 12.8 20.3 50 100 0.1 0.1 0.12 0.23 o.2 0.4 0.35 0.67 0.55 1.r 0.85 't .7 1.4 2.7 2.'l 4.2 3.4 6.8 5.4 10.8 a.4 16.8 10.6 21.'
, 300 Minimum Strokes for Auto Switch Mounting Unit: mm (in) D-Z7, Z8 D-Y5, Y6, Y7 D-Y7W, D-Y7BAL 180, 200 2 pcs.
P N E U T / | A T I C T E C H N O L O G Y Average plston speed ln mm/s 150 200 250 300 400 0.15 0.2 0.25 0.3 0.4 0.36 0.46 0.6 0.72 1 1000 1 2.4 4 6.7 1 1 1 7 27 500 0.5 750 0.75 1.8 3 5 8.5 12.8 20.3 50 100 0.1 0.1 0.12 0.23 o.2 0.4 0.35 0.67 0.55 1.r 0.85 't .7 1.4 2.7 2.'l 4.2 3.4 6.8 5.4 10.8 a.4 16.8 10.6 21.'
Model Air flow [m3/min] Heat generation [W] HECR002-A 2 600 HECR004-A 5 1300 HECR006-A 5 1400 HECR008-A 7 1700 HECR010-A 7 2500 HECR008-W 0.2 200 HECR012-W 0.4 250 Operating Environment/Storage Environment Warning Facility Water Caution 1. Keep within the specified ambient temperature and humidity range.
, 300, 350, 400 MGCM Slide bearing 350, 400, 450, 500 350, 400, 450, 500, 600 75, 100, 125, 150, 350, 400, 450, 500, 600, 700, 800 200, 250, 300 MGCL Ball bushing baering 350, 400, 450, 500, 600, 700, 800, 900, 1000 *Short stroke or intermediate stroke(except above stroke): Manufactured upon receipt of order 3.20-2 Compact Guide Cylinder Series MGC Specifications MGCll20 MGCll25 MGCll32 MGCll40
Number of command input pulses per revolution *3 PA05 0 0 Electronic gear numerator *3 PA06 1 32768 Electronic gear denominator *3 PA07 1 250 150 75 300 200 100 375 250 125 Regenerative option PA02 0 0(Non) / 0002(LEC-MR-RB-032) Rotation direction selection *4 PA14 0 1(+Counter motors side) Adaptive tuning mode PB01 0 0 Load to motor inertia moment ratio PB06 7 7 Machine resonance suppression
For details on how the models are indicated, refer to How to Order. 315 or more 50 200 or more 63 CCT63 120 or more 80 75 or more 100 1164 Air-hydro Unit CC Series Data (A) Volume of Cylinder/Capacity of Converter 160 140 125 100 800 700 600 300 250 200 180 10,000 8,000 500 400 80 6,000 5,000 4,000 300 600 500 63 3,000 200 400 50 2,000 300 40 Effective oil level stroke (mm) 500 200 1,000
Data (A) Volume of Cylinder/Capacity of Converter 160 140 180 125 300 250 800 700 600 200 Selection Step 100 10,000 8,000 6,000 5,000 4,000 500 400 Step (1) Select the bore size of air-hydro cylinder 80 300 First of all, select a bore size from data (D)
When the source pressure is 1700 psig (11.7 MPa), achievable delivery pressure is around 125 psig (0.86 MPa ) (HF and FC option 120 psig (0.83 MPa)). 2) 250 psig outlet pressure preset at 800 psig (5.5MPa) inlet pressure. Custom inlet/outlet pressure settings available.
Data A Volume of cylinder/Capacity of converter 180 160 140 125 100 300 250 800 700 600 How to Select 200 10,000 8,000 6,000 5,000 4,000 3,000 500 400 qSelect the bore size of air-hydro cylinder 80 First of all, select a bore size from data
, 300 300 Other intermediate strokes can be manufactured upon receipt of order.
, 300 300 Other intermediate strokes can be manufactured upon receipt of order.
262.5 275 287.5 300 L3 180.5 191 201.5 212 222.5 233 243.5 254 264.5 275 L4 15 16 17 11.5 12.5 13.5 14.5 15.5 16.5 17.5 Manual override In case of locking type, ( turn after pushing in ) 4-One-touch fitting (ports P, R) Applicable tube O.D.: 8 (L4) L3 8 U side D side 52.9 <53.6> 4.1 [46] [54.5] 22.5 1 32 P P 5.5 B B A B A B A B A B 4.7 35 23.5 44.4 <45.1> 10.2 26 3 R R A A G: Approx. 300