Series: VQ1000, IN Port Size: C3 (One-touch Fitting for ø3.2), OUT Port Size: C3 (One-touch Fitting for ø3.2), Option: DN (D + N)
Series: VQ1000, IN Port Size: C3 (One-touch Fitting for ø3.2), OUT Port Size: C3 (One-touch Fitting for ø3.2)
Series: VQ1000, IN Port Size: C3 (One-touch Fitting for ø3.2), OUT Port Size: C3 (One-touch Fitting for ø3.2), Option: FN (F + N)
Series: VQ1000, IN Port Size: C3 (One-touch Fitting for ø3.2), OUT Port Size: C3 (One-touch Fitting for ø3.2), Option: F (Bracket)
(Nm) L(mm) MHM-16D M3x0.5 0.63 6 MHM-25D M4x0.7 1.5 8 MHM-32D M5x0.8 3 10 MHM-50D M6x1 5.2 12 (N) MHM-16D 100 MHM-25D 200 MHM-32D 300 MHM-50D 500 -7- 2-3. 40 2-4. () 5 5 P-01-11 -8- 2-5. 1.52 2-6. 1 ()ISO VG320 (SDS) -9- 2-7. 1) 1) 2) 3) 12mm -10- 2 C3 C1 C2: C3 D-M9V D-M9WV D-M9AV D-M9 D-M9W D-M9A D-P3DWA A B E G A B E G L A B E G L D F H MHM-16D 9.1 9.1 5.6 4.6 8.1 12.8 11
Composite tube only) S T Y L E Standard Cylinder W Double Rod (Please see Page 19 for Mounting Information) K Non-rotating Piston Rod (5 to 14) O P T I O N S A Special Rod Thread (See Page 22) B5 Oversized Rod (See Char t below) B6 High Temperature * C3 Por t and Cushion Location (see Page 23) C6 Stainless Steel Piston Rod (Std. on XTSS series) C8 Adjustable Stroke Extended Piston Rod *
Specification SV1000 SV2000 Applicable series Stacking type cassette base manifold Manifold type Common SUP, EXH 1 (P: SUP)/3, 5 (E: EXH) type Valve stations (maximum) 18 stations 20 stations Max. number of solenoids 18 points 26 points 1(P)/3, 5 (E) port C8, N9 C10, N11 Port size C3, C4, C6 N1, N3, N7 C4, C6, C8 N3, N7, N9 4(A)/2(B) port Flow Characteristics Flow characteristics Port size
Manual operation C2 Air operated C3 N.O. Nil Non-locking push type C4 Double SOL.
number 1 Terminal Function Common terminal Optional cable color White COM ON: Motor output OFF: No motor output ON: Adjusted thrust OFF: 100% thrust (Max. thrust) ON: A-PHASE (Retracted side) OFF: B-PHASE (Extended side) Output ON command input Red 2 ON Adjusted thrust command input Yellow SET 3 Traveling direction command input A-PHASE 4 Orange Cable for motor output terminal LC3F2 1 C3
(R1)5 1 (P) 3(R2) For adding stations Rubber seal 3 position closed center 2(B) (A)4 3 Port plug mounting port (R1)5 1 (P) 3(R2) Nil A B None Port 4(A) Port 2(B) 3 position exhaust center 2(B) (A)4 4 Cylinder port (R1)5 1 (P) 3(R2) Symbol Port size Port location 3 position pressure center C3 C4 C6 M5 L3 L4 L6 L5 With 3.2 One-touch fittings With 4 One-touch fittings With 6 One-touch fittings
Manifold Specifications Piping specifications Applicable stations Note 2) 5 station weight (g) Port direction Applicable solenoid valves Port size Note 1) Series Connection type Base model 2, 4 (A, B) 1, 3 (P, R) C8 (For 8) C3 (For 3.2) 628 (Single) F, L, M and P kits 1 to 12 stations VQC100-5 Options Direct outlet with built-in silencer C4 (For 4) VQC1000 VV5QC11Side C6 (For 6) 759 (Double
Composite tube only) S T Y L E Standard Cylinder W Double Rod (Please see Page 19 for Mounting Information) K Non-rotating Piston Rod (5 to 14) O P T I O N S A Special Rod Thread (See Page 22) B5 Oversized Rod (See Char t below) B6 High Temperature * C3 Por t and Cushion Location (see Page 23) C6 Stainless Steel Piston Rod (Std. on XTSS series) C8 Adjustable Stroke Extended Piston Rod *
SI Unit: QW (DeviceNet), Input Block Stations: 43 (4 Stations/M8: 4 Inputs 3 Pins), Input Block COM: +COM, Stations: 16 Stations, SUP/EXH Block Mounting: B (Both Sides 2~20 Stations), Pilot: Internal Pilot, A, B Port: C3 (ø3.2 One-touch Fitting), Mounting Method: None, US Option: X160US (Preferred US Option for DeviceNet Type)
SI Unit: ZCN [ControlNet (IP40)], Input Block Stations: 61 (6 Stations/M12: 2 Inputs), Input Block COM: +COM, Stations: 16 Stations, SUP/EXH Block Mounting: B (Both Sides 2~20 Stations), Pilot: Internal Pilot, A, B Port: C3 (ø3.2 One-touch Fitting), Mounting Method: D (DIN Rail Mounting)
SI Unit: DeviceNet, Input Block Stations: 4 Stations/M8: 4 Inputs 3 Pins, Input Block COM: +COM, Stations: 16 Stations, SUP/EXH Block Mounting: Both Sides 2~20 Stations, Pilot: Internal Pilot, A, B Port: ø3.2 One-touch Fitting, Mounting Method: None, US Option: Preferred US Option for DeviceNet Type
SI Unit: ZCN [ControlNet (IP40)], Input Block Stations: 6 Stations/M12: 2 Inputs, Input Block COM: +COM, Stations: 16 Stations, SUP/EXH Block Mounting: Both Sides 2~20 Stations, Pilot: Internal Pilot, A, B Port: ø3.2 One-touch Fitting, Mounting Method: DIN Rail Mounting, US Option: -
Series: 1 (JSY1000), Type: 10S (Side-Ported, Serial Interface, EX250), SI Unit: 0 (w/o SI Unit), Input Block Stations: None, Input Block Type: w/o Input Block, Valve Stations: 16 Stations, P,E Port, SUP/EXH Assembly: B (Internal Pilot, Both Sides, 2 to 24 Stations), A,B Port Size: C4 (ø4 One-touch Fitting)
Series: 3 (JSY3000), Type: 10S (Side-Ported, Serial Interface, EX250), SI Unit: 0 (w/o SI Unit), Input Block Stations: None, Input Block Type: w/o Input Block, Valve Stations: 16 Stations, P,E Port, SUP/EXH Assembly: B (Internal Pilot, Both Sides, 2 to 24 Stations), A,B Port Size: C8 (ø8 One-touch Fitting)
Series: 5 (JSY5000), Type: 10S (Side-Ported, Serial Interface, EX250), SI Unit: 0 (w/o SI Unit), Input Block Stations: None, Input Block Type: w/o Input Block, Valve Stations: 16 Stations, P,E Port, SUP/EXH Assembly: B (Internal Pilot, Both Sides, 2 to 24 Stations), A,B Port Size: C10 (ø10 One-touch Fitting)
Series: 3 (JSY3000), Type: 10S (Side-Ported, Serial Interface, EX250), SI Unit: 0 (w/o SI Unit), Input Block Stations: None, Input Block Type: w/o Input Block, Valve Stations: 16 Stations, P,E Port, SUP/EXH Assembly: B (Internal Pilot, Both Sides, 2 to 24 Stations), A,B Port Size: C6 (ø6 One-touch Fitting)