SMC Corporation of America
Elite Part Number Search
Search Results "SS5Y3-52F1-05B-00T"

Model: Top Ported, Connector Type: D-sub Connector, 25 Pins, Connector Entry Direction: Upward, Wiring Specification: All Single Wiring, Valve Stations: 6 Stations, P, E Port Location: U Side, Thread: NPT, Mounting: DIN Rail Mounting w/DIN Rail

Model: Top Ported, Connector Type: D-sub Connector, 25 Pins, Connector Entry Direction: Upward, Wiring Specification: All Double Wiring, Valve Stations: 5 Stations, P, E Port Location: U Side, Thread: NPT, Mounting: -

Model: Top Ported, Connector Type: D-sub Connector, 25 Pins, Connector Entry Direction: Upward, Wiring Specification: All Double Wiring, Valve Stations: 12 Stations, P, E Port Location: U Side, Thread: Rc, Mounting: DIN Rail Mounting w/o DIN Rail

Model: Top Ported, Connector Type: D-sub Connector, 25 Pins, Connector Entry Direction: Upward, Wiring Specification: All Double Wiring, Valve Stations: 12 Stations, P, E Port Location: Both Sides, Thread: Rc, Mounting: DIN Rail Mounting w/DIN Rail

Model: Top Ported, Connector Type: D-sub Connector, 25 Pins, Connector Entry Direction: Upward, Wiring Specification: All Double Wiring, Valve Stations: 8 Stations, P, E Port Location: Both Sides, Thread: Rc, Mounting: DIN Rail Mounting w/o DIN Rail

05-01 VV3K3-20-04 Common SUP/Common EXH Type 20: Body ported (A port top ported) How to Order Applicable solenoid valve VK332--M5(-Q) VK332--01(-Q) Applicable blanking plate assembly VK300-42-1A Bracket VK300-43-1A VV3K3 05 20 A port: Rc 1/8, M5 x 0.8 Valve stations Option P, R port thread type 01 1 station Nil None Nil F With bracket (Not mounted) 20 Rc G NPT NPTF 20 stations 00F 00N 00T

Fittings & Tubing Air Cylinders Rotary Actuators How to Order Manifold 10 SS5Q13 08 FD2 D CE-compliant Clean series Nil Q CE-compliant Stations 1 station 01 1(P), 3(R) port size 24 Note) 24 stations Nil 1(P), 3(R) port 8 One-touch fittings 1(P), 3(R) port 5/16" One-touch fittings Note) The maximum number of stations depends on the type of electrical entries. 00T Option Nil 02 to 24 Note

Stations -+ -+ -+ -+ P, R port thread type Bracket 02 : 20 2 Stations : 20 Stations Nil Rc G NPT NPTF R P CE-compliant Nil F Without bracket 00F 00N 00T P port Nil Q With bracket 1/8 R port 1/8 CE-compliant Note) For more than 6 stations, supply air to both sides of P port and exhaust air from both sides of R port.

.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com Rc G NPT NPTF 01 1 station Nil None 00F 00N 00T F With bracket (Not mounted) VT 20 20 stations P port: Rc 1/8 R port: Rc 1/8 VP Type 40: Base mounted (A port bottom ported) How to Order Applicable solenoid valve VK334Applicable blanking plate assembly

Thread type 1(P), 3(R) port Nil Rc 00N NPT 00T NPTF 00F G Dusttight/Low Jetproof Type (IP65) DIN terminal is available with dusttight/low jetproof (IP65) type.

.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com SS5X3-20-05 (5 stations) NPTF 00T Stations3 2 1 Connector assembly for L and M types Refer to page 1-6-8. Common connector assembly for manifold Refer to page 1-6-9. SS5X3-20-05 1 set (Type 20, 5-station manifold base part no.)

Thread type (1(P), 3(R2), 5(R1)) ports) Nil Rc 00N NPT 00T NPTF 00F G Dusttight/Low Jetproof Type (IP65) DIN terminal is available with Dusttight/Low jetproof (IP65) type.

Type 20 (5 Port/Body ported) How to Order Applicable solenoid valve M5 C4 C6 M5 C4 C6 SS5YJ520 05 SYJ520-A, B port M5 x 0.8 SYJ523-Applicable blanking plate assembly SYJ5000-21-1A Applicable individual EXH spacer assembly SYJ5000-17-1A P, R port thread type Number of stations -+ -+ P port 1/8 02 2 stations R R P Nil 00F 00N 00T Rc G NPT NPTF : : 20 20 stations R port 1/8 Type 40 (5 Port/

Type 21R Applicable solenoid valve SYJ512R---M5 SYJ522R---M5 How to Order SS3YJ5--21R-05 -A port M5 x 0.8 X port (External pilot type) P, R port thread type Stations Applicable blanking plate assembly SYJ500-10-1A + + + + M5 x 0.8 02 : 20 2 stations : 20 stations Nil Rc G NPT NPTF X 00F 00N 00T P port 1/8 P R R port 1/8 Note) For more than 9 stations, supply/exhaust air to/from both sides

Applicable blanking plate assembly SYJ7000-21-1A Type 21 (5 Port/Body ported) How to Order SS5YJ721 05 A, B port P, R port thread type Applicable individual EXH spacer assembly SYJ7000-17-1A Stations 02 2 stations + + Nil 00F 00N 00T Rc G NPT NPTF : : P port 1/4 R P R 20 20 stations R port 1/4 Note) For more than stations, supply air to both sides of P port and exhaust air from both sides

Type 21R How to Order SS3YJ7--21R-05 -Applicable solenoid valve SYJ712R--01 SYJ722R--01 A port 1/8 P, R port thread type Applicable blanking plate assembly SYJ700-10-2A -+ -+ -+ -+ Stations X port (External pilot type) 02 : 20 2 stations : 20 stations Nil R X Rc G NPT NPTF P 00F 00N 00T M5 x 0.8 R port 1/4 P port Note) For more than 9 stations, supply/exhaust air to/from both sides of P and

S 20 20 stations A,B port side R1,R2 Port M5T M5 0.8 M5 0.8 R1,R2 Port M5 0.8 N3T One-touch fitting A, B Port M5 0.8,N3T P Port NPTF P Port NPTF A, B Port M5 0.8,N3T How To Order: Flat Ribbon Cable Manifold Type 21P (4 Port/Body Ported Type) Applicable valve: SYJ3 23 LOU --M3 SYJ3 23Y LOU --M3 5 6 5 6 AB Port M3 0.5 SS5YJ3--21P-07 00T Applicable connector ass'y: SY3000-37-28A (For 2

disassembling the entire manifold Seal type allows selection of metal seals or rubber seals Type of actuation Cylinder port size 2 position 3 position One-touch fitting Pressure center Effective area mm (Cv factor) Exhaust center Closed center Series C3 C4 C6 (6) M5 (3.2) (4) Double Single VQ130 Metal seal VQ131 Rubber seal 4.5 (0.25) 6.3 (0.35) 54 Series VQ1000 How to Order Manifolds VV5Q13 (-00T

YZ-DIN connector YOS-DIN terminal without connector With light and surge voltage suppressor With surge voltage suppressor Note) Standard lead wire length: 300mm Coil voltage 1 2 3 4 5 6 9 100VAC(50/60Hz) 200VAC(50/60Hz) 110VAC(50/60Hz) 220VAC(50/60Hz) 24VDC 12VDC Others 21 Series VQZ How To Order Manifold Connector Kit How To Order: VQZ100 Body Ported Manifold Preferred Option Program C 00T

Rubber seal 0.15 to 0.7MPa 0.2 to 0.7MPa VQZ100: (Poppet ) How to Order Manifold Operating press. range (1) Vacuum to 0.7MPa VV3QZ22 05C 00T Note 1) In case of the high pressure style, the upper limit of max. operating pressure and external pressure range is 1MPa. Note 2) If VQZ100 is applied in vacuum, vacuum from P port.