Nil 30 50 0.6 m 3 m 5 m Example) ZSE2-0R-15CN . 1 pc. ZS-10-5A-50 . 1 pc. 13-3-13 13 Series ZR Vacuum Pressure Switch Unit/Pressure Switch for Vacuum: ZSE2-0R-15 Guidelines for Use of Vacuum Pressure Switch Unit System circuit for work adsorption Set pressure When it is used for work adsorption, set the pressure so that adsorption is complete and reliable.
/60 Hz 2 200 VAC, 50/60 Hz Applicable model 3 110 VAC, 50/60 Hz Applicable model Body type Plug-in type Symbol Electrical entry 4 220 VAC, 50/60 Hz 1 2 position single Plug-in F Note) A Single/ Double A side 5 24 VDC 2 2 position double 6 12 VDC G Grommet Grommet, With surge voltage suppressor 3 3 position closed center B Double B side 9 Other Option 4 3 position exhaust center GS 3A
ZS-10-5A-50 1 pc. (For 110 VAC) 3A 36 VJ10 6 Ejector System/Recommended Model (The models below will have shorter deliveries.)
VCC Series Dimensions Manifold Pilot port C4: 4 One-touch fitting C6: 6 One-touch fitting G1/4 (RETURN port) G1/4 (IN port) VV2CC1 VVMCC1, VV3CC1 30 31 0.5 to 2 0.5 to 2 10 10 20 G1/4 OUT port 0.5 to 2 0.5 to 2 20 G1/4 OUT port n-1 9 7 5 3 1 122.2 <124.2> 142.2 <144.2> 142.2 <144.2> 120 122.2 <124.2> 100 22.6 100 120 80 25 75 50 n 1 0 8 6 4 2 50 67.5 <69.5> L1 8 67.5 <69.5> 64.9 L2 4 x 9
30 or less 30 or less 50 or less 65 or less 30 or less 30 or less 30 or less 30 or less 40 or less 55 or less 40 or less 45 or less 40 or less 40 or less 40 or less ON OFF ON OFF AC Response time (ms) (at the pressure of 0.5 MPa) DC 55 or less 40 or less 45 or less 30 or less 30 or less Note) Based on dynamic performance test, JIS B 8375-1981.
Recommended Parameter Values [LEF] LEFS25T6 LEFS32T7 LEFS40T8 Lead symbol H A B H A B H A B Series Lead 20 12 6 24 16 8 30 20 10 Parameter *1,*2 Para. Initial value Recommended value No.
(Turn proof structure at pressurized state) 1.17-2 AL1000 to 6000 Standard Specifications AL1000 AL2000 AL3000 AL4000 AL4000-06 AL5000 AL6000 Model 1/8, 1/4 1/4, 3/8 1/4, 3/8, 1/2 3/4 3/4, 1 1 M5 X 0.8 Port Size Air 1.5MPa 1.0MPa Fluid Proof pressure Max. operating pressure 1/4: 30 3/8: 40 1/2: 50 130 1/4: 30 3/8: 40 50 Min.operating flow (l/min (ANR))(1) 50 190 220 4 15 130 130 130 7 25
S Z Without lead wire: (with connector and 2 of sockets only) SY100-30-A Rated voltage R Lead wire length U 5 6 V S R 1 2 24 VDC 12 VDC 6 VDC 5 VDC 3 VDC 100 VAC 50/60 Hz 200 VAC 50/60 Hz 110 VAC 50/60 Hz [115 VAC 50/60 Hz] Nil 6 10 15 20 25 30 50 300 mm 600 mm 1000 mm 1500 mm 2000 mm 2500 mm 3000 mm 5000 mm For AC voltage valves there is no S option.
Nil E Yes Without light, with surge voltage suppressor Seal Metal seal Rubber seal 0 1 Coil voltage Function 1 2 3 Stations 1 2 3 4 5 6 100 VAC (50/60 Hz) 200 VAC (50/60 Hz) 110 VAC (50/60 Hz) 220 VAC (50/60 Hz) 24 VDC 12 VDC D side U side Standard type (1 W) Low wattage type (0.5 W) External pilot Nil Y R (1) (2) Applicable to DC sepecifications.
Max. voltage (with no load): 30 Vrms (42.4 V peak) or less Max. current: (1) 8 A or less (including shorts), and (2) When controlled by a circuit protector (fuse, etc.) with the following rating Max. current rating 5.0 100 Peak voltage value No-load voltage (V peak) 0 to 20 [V] Over 20 [V] to 30 [V] 2) A circuit (class 2 circuit) with maximum 30 Vrms (42.4 V peak) or less, and a power supply
30 31 30 33 46 42 0D 0A Read Address Quantity to Read Hi Lo Hi Lo 30 30 30 30 30 30 30 31 Response message (Slave to Master) Start Slave Address Function Data LRC End 3A 30 31 30 33 30 43 0D 0A Byte Count Read Data1 Hi Lo 30 32 30 30 45 45 HRS090 Series 4.5 Message configuration 4-9 HRX-OM-T004 Chapter 4 MODBUS communication function 4.6 Function codes Table 4.6-1 shows function codes to
30 31 30 33 46 42 0D 0A Read Address Quantity to Read Hi Lo Hi Lo 30 30 30 30 30 30 30 31 Response message (Slave to Master) Start Slave Address Function Data LRC End 3A 30 31 30 33 30 43 0D 0A Read Data1 Byte Count Hi Lo 30 32 30 30 45 45 HRSH Series 4.5 Message configuration 4-9 HRX-OM-R028 Chapter 4 MODBUS communication function 4.6 Function codes Table 4.6-1 shows function codes to
40-140'F(5-m'c 2 -20 inch/sec {50 -500 mm/sec) 2 -30 jnch/sec (50-750 mm/sec) Not required (prelubricated at factory) Standard Stroke LLst Owhen mounting, completelyflush the piping and be careful that dust and chips do not erterthe cylinder. )Load of piston rod should always be aligned parallel with the cylinder axis.
40-140'F(5-m'c 2 -20 inch/sec {50 -500 mm/sec) 2 -30 jnch/sec (50-750 mm/sec) Not required (prelubricated at factory) Standard Stroke LLst Owhen mounting, completelyflush the piping and be careful that dust and chips do not erterthe cylinder. )Load of piston rod should always be aligned parallel with the cylinder axis.
Port block assembly (cassette type) Port block assembly (screw-in type) How to Order Connector Assembly For DC : SY100-30-4AFor 100VAC : SY100-30-1AMounting screws For 200VAC : SY100-30-2AFor other AC : SY100-30-3AWithout lead wires : SY100-30-A (connector, socket x 2pcs. only) Lead wire length 300mm 600mm 1000mm 1500mm 2000mm 2500mm 3000mm 5000mm Nil 6 10 15 20 25 30 50 Fitting assembly
Confirm that the connector portion does not move. 14.9 Gray: Ground Black: DC24V 10% ( power supply for input and control ) Blue: 0V ( for input and control ) White: DC24V+10%/-5% ( for solenoid valves/output ) 18 48 34 Straight connector Type Angle connector Type EX500-AP -S EX500-AP -A 6 30 5 50 31.3 28.3 6 Socket Connector Pin Layout 4 3 1 5 30 5 50 2 B. Single power supply system A.
40 30 20 10 0 100 90 80 70 60 50 40 30 20 10 0 Vacuum pressure [kPa] Vacuum pressure [kPa] ZL3H ZL3H04P ZL3M ZL3M04P Suction flow rate [L/min (ANR)] 100 50 200 150 300 250 350 0 Suction flow rate [L/min (ANR)] 100 50 200 150 300 250 350 0 23 Multistage Ejector ZL3/ZL6 Series Flow Rate Characteristics (Representative value) ZL6M (04P) Supply pressure: 0.35 MPa/0.37 MPa (With valve) ZL6H (
Without lead wire: (with connector and 2 of sockets only) SY100-30-A Rated voltage Lead wire length 5 6 V S R 1 2 24 VDC 12 VDC 6 VDC 5 VDC 3 VDC 100 VAC 50/60 Hz 200 VAC 50/60 Hz 110 VAC 50/60 Hz [115 VAC 50/60 Hz] Nil 6 10 15 20 25 30 50 300 mm 600 mm 1000 mm 1500 mm 2000 mm 2500 mm 3000 mm 5000 mm Electrical entry G H L LN LO M MN MO W0 Grommet, 300 mm lead wire Grommet, 600 mm lead wire
Dynamic moment Me3 We W L2 Review Me3. = 1/3 14.7 (50 + 27) 103 = 0.38 [Nm] 3a = Me3/Me3 max = 0.38/3 = 0.13 Central axis of guide A Me1 W We Me1 = 1/3 We(L1 + B) 103 = 1/3 14.7 (50 + 48) 103 L1 B = 0.48 [Nm] 3b = Me1/Me1 max = 0.48/3 = 0.16 Review Me1.
/60 Hz 200 VAC, 50/60 Hz 110 VAC, 50/60 Hz 220 VAC, 50/60 Hz JIS Symbol Internal pilot