Rated Vacuum Range: F (-100 to 100 kPa), Output Specification: V (PNP Open Collector 2 Outputs + Analog Current Output), Unit Specification: P (Unit Selection Function, Initial value psi), Piping Specification: N7L (ø1/4" One-touch Fitting, Elbow Type), Lead Wire: J (Lead Wire w/Connector, 5-core, 2 m Lead Wire), Bracket: A2 (Bracket B, Horizontal Mounting)

Rated Vacuum Range: F (-100 to 100 kPa), Output Specification: T (PNP Open Collector 2 Outputs + Analog Voltage Output), Unit Specification: P (Unit Selection Function, Initial value psi), Piping Specification: M5 (Female Thread), Lead Wire: J (Lead Wire w/Connector, 5-core, 2 m Lead Wire), Bracket: A2 (Bracket B, Horizontal Mounting)

Rated Vacuum Range: F (-100 to 100 kPa), Output Specification: S (NPN Open Collector 2 Outputs + Analog Current Output), Unit Specification: P (Unit Selection Function, Initial value psi), Piping Specification: N7L (ø1/4" One-touch Fitting, Elbow Type), Lead Wire: J (Lead Wire w/Connector, 5-core, 2 m Lead Wire), Bracket: A2 (Bracket B, Horizontal Mounting)

Rated Vacuum Range: F (-100 to 100 kPa), Output Specification: R (NPN Open Collector 2 Outputs + Analog Voltage Output), Unit Specification: P (Unit Selection Function, Initial value psi), Piping Specification: M5 (Female Thread), Lead Wire: J (Lead Wire w/Connector, 5-core, 2 m Lead Wire), Bracket: A2 (Bracket B, Horizontal Mounting)

5 y e o r !0 !6 !5 y e o i r q !9 r u e y o i !0 i t !2 q !1 @0 !7 t !2 u !1 !7 !0 t !2 !7 !1 !5 !6 Component Parts Description Note Description No. Material Material Note No.

Rated Vacuum Range: F (-100 to 100 kPa), Output Specification: Y (PNP Open Collector 2 Outputs + Copy Function), Unit Specification: Unit Selection Function, Switches w/Unit Selection not Permitted for Use in Japan, Piping Specification: N01 (NPT 1/8), Lead Wire: J (Lead Wire w/Connector, 5-core, 2 m Lead Wire), Bracket: A1 (Bracket A, Vertical Mounting)

Rated Vacuum Range: -100 to 100 kPa, Output Specification: PNP Open Collector 2 Outputs + Copy Function, Unit Specification: Unit Selection Function, Switches w/Unit Selection not Permitted for Use in Japan, Piping Specification: NPT 1/8, Lead Wire: w/o Lead Wire, Bracket: Bracket A, Vertical Mounting, Operation Manual: Operation Manual, Calibration Certificate

Rated Vacuum Range: -100 to 100 kPa, Output Specification: PNP Open Collector 2 Outputs + Copy Function, Unit Specification: Unit Selection Function, Switches w/Unit Selection not Permitted for Use in Japan, Piping Specification: NPT 1/8, Lead Wire: Lead Wire w/Connector, 5-core, 2 m Lead Wire, Bracket: -, Operation Manual: -

Rated Vacuum Range: -100 to 100 kPa, Output Specification: PNP Open Collector 2 Outputs + Copy Function, Unit Specification: Unit Selection Function, Switches w/Unit Selection not Permitted for Use in Japan, Piping Specification: NPT 1/8, Lead Wire: Lead Wire w/Connector, 5-core, 2 m Lead Wire, Bracket: Panel Mount Adapter, Operation Manual: -

Rated Vacuum Range: -100 to 100 kPa, Output Specification: PNP Open Collector 2 Outputs + Copy Function, Unit Specification: SI Unit Only, Piping Specification: NPT 1/8, Lead Wire: -, Bracket: -, Operation Manual: -

Rated Vacuum Range: F (-100 to 100 kPa), Output Specification: Y (PNP Open Collector 2 Outputs + Copy Function), Unit Specification: Unit Selection Function, Switches w/Unit Selection not Permitted for Use in Japan, Piping Specification: N01 (NPT 1/8), Lead Wire: w/o Lead Wire, Bracket: A1 (Bracket A, Vertical Mounting), Operation Manual: K (Operation Manual, Calibration Certificate)

Rated Vacuum Range: F (-100 to 100 kPa), Output Specification: Y (PNP Open Collector 2 Outputs + Copy Function), Unit Specification: Unit Selection Function, Switches w/Unit Selection not Permitted for Use in Japan, Piping Specification: N01 (NPT 1/8), Lead Wire: J (Lead Wire w/Connector, 5-core, 2 m Lead Wire)

Rated Vacuum Range: F (-100 to 100 kPa), Output Specification: Y (PNP Open Collector 2 Outputs + Copy Function), Unit Specification: Unit Selection Function, Switches w/Unit Selection not Permitted for Use in Japan, Piping Specification: N01 (NPT 1/8), Lead Wire: J (Lead Wire w/Connector, 5-core, 2 m Lead Wire), Bracket: B (Panel Mount Adapter)

Rated Vacuum Range: F (-100 to 100 kPa), Output Specification: Y (PNP Open Collector 2 Outputs + Copy Function), Unit Specification: M (SI Unit Only), Piping Specification: N01 (NPT 1/8)

AV Regulating pressure range AU Ambient and operating temperature range Weight AF Model AR Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com Port size Model IR IN OUT ARJ310-01 ARJ310-N01 ARJ310F-01-04 ARJ310F-01-06 ARJ310F-N01-03 ARJ310F-N01-07 Rc 1/8 R 1/8, M5 x

-01 12.7 20.4 27.5 9.3 4 1/8" 16 20.4 27.5 17 9.3 12.7 AS221FG-01-06 AS221FG-N01-03 14.3 13.5 20.4 27.5 11.6 6 5/32" 14.2 31.1 36.1 12 32.1 27.1 NPT 1/8 R 1/8 17 AS221FG-01-08 AS221FG-N01-05 12.7 14.3 23.1 30.2 19 18.5 25.3 32.4 15.2 11.4 36.1 8 3/16" 31.1 32.1 27.1 16.5 14.2 AS221FG-01-10 AS221FG-N01-07 23.9 31 15 21 21 33.1 40.2 18.5 13.2 10 1/4" 18.5 19 AS221FG-02-04 AS221FG-N01-09 15

3 r e o y !5 !6 q r i o e y !5 !6 !0 y i o e u r !9q !7 !0 !1 i !2 t u !7 @0 !1 q !2 t !6 !5 !7 !2 t !0 !1 Component Parts Note Description U seal U seal Cassette Seal O-ring O-ring O-ring O-ring O-ring Gasket Spacer ASD230F only Material HNBR HNBR POM, Stainless steel (1) Description No. !1 !2 !3 !4 !5 !6 !7 !8 !

One-touch fitting ARJ310-01 ARJ310-N01 ARJ310F-01-04 ARJ310F-01-06 ARJ310F-N01-03 ARJ310F-N01-07 R 1/8, M5 x 0.8 NPT 1/8, M5 x 0.8 R 1/8, M5 x 0.8 NPT 1/8, M5 x 0.8 Note) M5 x 0.8 female thread is cut inside the pipe.

Output Specification: Y (PNP Open Collector 2 Outputs + Copy Function), Unit Specification: M (SI Unit Only), Piping Specification: N01 (NPT 1/8), Lead Wire: J (Lead Wire w/Connector, 5-core, 2 m Lead Wire), Bracket: A2 (Bracket B, Horizontal Mounting)