(With light: 1.2 W), 100 VAC: 1.4 W (1.45 W), 110 VAC: 1.45 W (1.5 W) Air Operated Valve Specifications Refer to page 13-4-11 for dimensions.
Apparent power (VA) Volt-ampere is the product of voltage (V) and current (A). Power consumption (W): For AC, W = VAcos. For DC, W = VA. Note) cos shows power factor. cos 0.9 3. Symbol When the valve is closed, flow is blocked from port 1 to port 2.
L TX TV TK Round type/CJ-CR MM TDH10 A TY TT C0.5 TW RR L N Material: Stainless steel 304 W DPart no.
Auto Switch Internal Circuits Auto Switch Weights Unit: g D-F9N, F9NV D-F9N(V) D-F9P(V) D-F9B(V) Auto switch part no.
(mm) 1 1 1 1 Outer layer thickness (mm) Black (B) Outer layer color White (W) Red (R) Blue (BU) Yellow (Y) Green (G) CAT.ES50-35A Series TRTU Flame Resistant (Equivalent to UL-94 Standard V-0) FR Three-layer Polyurethane Tubing SeriesTRTU RoHS Model P 20 m roll l 100 m reel Model TRTU1208 12 TRTU0604 6 TRTU0805 8 TRTU1065 10 Inner tube O.D. (mm) Inner tube I.D.
), 2.3 VA (60Hz) Apparent power 1.8 W (Without indicator light), 2 W (With indicator light) Power consumption Manual override Non-locking push type Accessory/Part No.
IS1000-01 Model 0.1 to 0.4 MPa Set pressure range (OFF) 0.08 MPa Differential 1a Contact point construction 2 VA AC, 2 W DC Max. contact point capacity 12 V 48 V 100 V 24 V Voltage (AC, DC) 50 mA 40 mA 20 mA 50 mA Max. current 1.2 ms Operating time 30 G Shock resistance JIS Symbol AMR5100 AMR4000 AMR3000 14-7-1 2 Series AMR3000 to 6000 How to Order E3 03 R S AMR 4 0 00 Adapter Assembly (Part
Cable color: Signal name 1 Brown: 0 V (Power supply for solenoid valve) 2 White: 24 VDC+10%/-5% (Power supply for solenoid valve) 3 Blue: 0 V (for input and control) 4 Black: 24 VDC10% (power supply for input and control) 5 Gray: Ground (FE) FE connection NOTE Connect the ground terminal to the ground.
Type Load voltage Wiring (Output) 3 (L) 1 (M) 0.5 (Nil) Auto switch model Band mounting DC AC Applicable load Lead wire length (m) Indicator light Electrical entry 5 (Z) M9B M9BW 5 V 12 V 24 V 2-wire Yes Grommet Solid state auto switch Relay, PLC A93 100 V Yes 12 V 24 V 2-wire Grommet Reed auto switch Note 1) Lead wire length symbols: 0.5 mNil M9BW 1 m M M9BWM 3 m L M9BWL 5 m Z M9BWZ
DC2410% 11/7 28/15 34/13 36/13 / (W) 8) 8/7 22/12 (W) 9) 14 42 19 51 57 61 1) 1020 150 LEHZ10,16:30(F.S.),LEHZ20,25:25(F.S.),LEHZ32,40:20(F.S.) 2) () 3) 5m 5m 10%(15m 20%) 4) 5) () 6) () 7) () 452000Hz 1 () 8) () 9) 11 - 2.1.2 6N LEHZ 10 K 4 2 1 R 1 2 10 10 D DIN D DIN 16 16 1DIN 2 0 2 0 I/O (m) L ) L ) 25 25 ) 10,16,20,25 32 32 1.5 1 1.5 1 40 40 3 3 3 3 5 5 5
w AR50, 60 AR30, 40 t q t q e e IN OUT IN OUT r w w r Parts list Material Note No.
For example, when the output voltage is 1 to 5[V], the F.S. will be 5-1 = 4[V]. (Reference: 1%F.S. = 4 0.01 = 0.04[V]) F.S. (full span/full scale) H Hysteresis Difference between the points at which the Pressure switch is turned on and off. I Indication accuracy Shows the deviation between displayed pressure value and the true pressure.
, S9P(V), 97/93A, 90/90A No.
-5 13 3 IDX-OM-W023 13 T IDU15E1-10-T IDU15E1-20/23-T PE 1 3 2 N L N L PE 1 2 3 TB TB MC TDR MC TDR ILS ILS MC TDR MC TDR PTC OLR MC PTC MC OLR CM CM MC C01 C02 MC CR C11 FM1 CR C11 PRS FM1 PRS P C12 FM2 P C12 TDR MC FM2 TDR MC IDU Series 13-5 13 4 IDX-OM-W023 14 V 14 V V IDU8E15E1-23 14-1 1. 1 2 2. 3.
Combination of K and V (Only one or the other may be attached.) Note 2) Standard specification is the power cable with plug.
D-Y7 W (V) 5 6 A B D-Y 9 Red light at ON Green light at ON Red light at ON Green light at ON MHW2-20D MHW2-25D MHW2-32D MHW2-40D MHW2-50D 4 6 15 5 11 4 5 11 4 9 2 4 9 3 7 2 3 6 2 5 2 3 5 2 4 2.8-24
Power saving circuit is not : SY100-30-A Without lead wire available in the case of W type.