Body Size: 40A, Thread: Rc (Rc: for Sizes 20, 30, 40; M5: for Size 10), Port Size: 04 (1/2), Option: G (for Sizes 20, 25, 30, 40 Round Type Pressure Gauge w/Limit Indicator; for Size10: Round Type Pressure Gauge w/o Limit Indicator), Attachment: Standard, Semi-Standard 1: 1 (0.02 to 0.2MPa Setting), Semi-Standard 2: Standard
Body Size: 40A, Thread: Rc (Rc: for Sizes 20, 30, 40; M5: for Size 10), Port Size: 04 (1/2), Option: G (for Sizes 20, 25, 30, 40 Round Type Pressure Gauge w/Limit Indicator; for Size10: Round Type Pressure Gauge w/o Limit Indicator), Attachment: Standard, Semi-Standard 1: 8 (Metal Bowl with Level Gauge), Semi-Standard 2: Standard
: °C), Bracket: None, Calibration Certificate: None, Series: Z (Flow Range: 04: 0.5 to 4 L/min , 20: 2 to 16 L/min, 40: 5 to 40 L/min, 11: 10 to 100 L/min)
Valve; w/Stop Valve), Supply/Return Port Size: 06 (3/4), Return Unit Flow Switch Output Specifications: FT (Out 1: PNP; Out 2: Flow Rate: Analog 4 to 20 mA ⇔ Analog 4 to 20 mA; Temperature Sensor: Yes), Lead Wire: w/Lead Wire and M8 Connector, 3 m, Return Unit Flow Switch Unit Specifications: F (Integrated Display: gal/min; Accumulated Flow: gal; Temp.: °F)
(w/Bracket), Calibration Certificate: A (w/Calibration Certificate), Series: Z (Flow Range: 04: 0.5 to 4 L/min , 20: 2 to 16 L/min, 40: 5 to 40 L/min, 11: 10 to 100 L/min)
Rated Flow Range: 40 (5 to 40 L/min), Flow Adjustment Valve: w/o Flow Adjustment Valve, Thread: N (NPT), Port Size: 04 (1/2), Output Specification/Temperature Sensor: KT (OUT1: Analogue 4 to 20 mA - OUT2: Analogue 4 to 20 mA; Temperature Sensor: Yes), Lead Wire: w/Lead Wire and M8 Connector, 3 m, Unit Specification: F (Instantaneous Flow: gal/min, Accumulated Flow: gal, Temperature: °F),
Valve; w/Stop Valve), Supply/Return Port Size: 06 (3/4), Return Unit Flow Switch Output Specifications: FT (Out 1: PNP; Out 2: Flow Rate: Analog 4 to 20 mA ⇔ Analog 4 to 20 mA; Temperature Sensor: Yes), Lead Wire: N (w/o Lead Wire and M8 Connector), Return Unit Flow Switch Unit Specifications: M (Integrated Display: L/min; Accumulated Flow: L; Temp.: °C; Integrated Display IO-Link: L/min
Valve; w/Stop Valve), Supply/Return Port Size: 04 (1/2), Return Unit Flow Switch Output Specifications: DT (Out 1: NPN; Out 2: Flow Rate: Analog 4 to 20 mA ⇔ Analog 4 to 20 mA; Temperature Sensor: Yes), Lead Wire: w/Lead Wire and M8 Connector, 3 m, Return Unit Flow Switch Unit Specifications: F (Integrated Display: gal/min; Accumulated Flow: gal; Temp.: °F)
The use of 34 pin connectors allows up to 16 stations with double solenoids.D-sub connector or Flat ribbon cable, Tie rod base, 4000 series, Number of connectors (D-sub): 25 pins, Maximum number of stations: 20, Number of connectors (Flat Ribbon): 26, 20, 10 pins 4/5 PORT SOLENOID VALVE. SS5V 04 Station Manifold, Tie-Rod Base. 0.82000 lb. VVM.
Rated Flow Range: 04 (0.5 to 4 L/min), Flow Adjustment Valve: S (w/Flow Adjustment Valve), Thread: N (NPT), Port Size: 03 (3/8), Output Specification/Temperature Sensor: FT (Out 1: PNP; Out 2: Flow Rate: Analog 4 to 20 mA ⇔ Analog 4 to 20 mA; Temperature Sensor: Yes), Lead Wire: N (w/o Lead Wire and M8 Connector), Unit Specification: M (Instantaneous Flow: L/min, Accumulated Flow: L,Temperature
Valve; w/Stop Valve), Return Port Size: 04 (1/2), Flow Switch Output Specifications: FT (Out 1: PNP; Out 2: Flow Rate: Analog 4 to 20 mA ⇔ Analog 4 to 20 mA; Temperature Sensor: Yes), Lead Wire: w/Lead Wire and M8 Connector, 3 m, Flow Switch Unit Specifications: F (Integrated Display: gal/min; Accumulated Flow: gal; Temp.: °F)
: °C), Bracket: R (w/Bracket), Calibration Certificate: A (w/Calibration Certificate), Series: Z (Flow Range: 04: 0.5 to 4 L/min , 20: 2 to 16 L/min, 40: 5 to 40 L/min, 11: 10 to 100 L/min)
Bracket: R (w/Bracket), Calibration Certificate: A (w/Calibration Certificate), Series: Z (Flow Range: 04: 0.5 to 4 L/min , 20: 2 to 16 L/min, 40: 5 to 40 L/min, 11: 10 to 100 L/min)
Flow Switch Type: 7 (Integrated Display), Rated Flow Range: 04 (0.5~4L/min), Return Unit: S (Flow Adjustment Valve), Thread: N (NPT), Port Size: 03 (3/8), Flow Switch Output: FT (Integrated Display; Out 1: PNP; Out 2: (Analog 4 to 20 mA) ⇔ Analog 4 to 20 mA ; Temperature Sensor: Yes), Lead Wire: N (without Lead Wire), Flow Switch Unit: J (Integrated Display; Instantaneous Flow: L/min; Accumulated
Rated Flow Range: 20 (2 to 16 L/min), Flow Adjustment Valve: S (w/Flow Adjustment Valve), Thread: Rc, Port Size: 04 (1/2), Output Specification/Temperature Sensor: F (Out 1: PNP; Out 2: Flow Rate: Analog 4 to 20 mA; Temp.: None; Temperature Sensor: None), Lead Wire: N (w/o Lead Wire and M8 Connector), Unit Specification: M (Instantaneous Flow: L/min, Accumulated Flow: L,Temperature: °C),
Certificate: None, Series: Z (Flow Range: 04: 0.5 to 4 L/min , 20: 2 to 16 L/min, 40: 5 to 40 L/min, 11: 10 to 100 L/min)
Rated Flow Range: 40 (5 to 40 L/min), Flow Adjustment Valve: w/o Flow Adjustment Valve, Thread: N (NPT), Port Size: 04 (1/2), Output Specification/Temperature Sensor: KT (OUT1: Analogue 4 to 20 mA - OUT2: Analogue 4 to 20 mA; Temperature Sensor: Yes), Lead Wire: N (w/o Lead Wire and M8 Connector), Unit Specification: M (Instantaneous Flow: L/min, Accumulated Flow: L,Temperature: °C), Bracket
This is a legacy product. Please contact us for the latest version.sales@ocaire.com
This is a legacy product. Please contact us for the latest version.sales@ocaire.com
This is a legacy product. Please contact us for the latest version.sales@ocaire.com