SMC Corporation of America
Elite Part Number Search
Search Results "10-VV5Q11-12C3FS3-D"

Pin Cylinder: Double Acting, Single Rod Series CJP2 4, 6, 10, 16 CJ1 How to Order CJP CJP2 10 F 15 D Standard CJ2 CDJP2 F 10 15 D M9BW S CM2 Built-in magnet CG1 Made to Order (Refer to page 24.) With auto switch (Built-in magnet) MB Mounting MB1 Mounting Standard Built-in magnet Symbol Number of auto switches 2 pcs. 1 pc.

8 10 8 10 10 12 10 12 10 12 10 R 1/8 23.4 27.4 39.8 45.8 17.6 14 R 1/4 25.4 31.4 39.8 45.8 17.6 12 R 1/8 26.7 30.7 45.3 52.8 24 14 R 1/4 28.7 34.7 45.3 52.8 24 17 R 3/8 30.4 36.7 45.3 52.8 24 17 R 1/4 33.8 39.8 49.6 55.6 30 17 R 3/8 35.5 41.8 49.6 55.6 30 22 R 1/2 37.6 45.8 49.6 55.6 30 Dimension with cover Reference dimension of R thread after installation.

Part No. of ejector valve for ZYY3000/ZYX3000 Number of ejectors 1 to 10 Ejector mounting position U D U side D side [Example: When individual wiring type model 45 for SY3000 is selected] ZZY Y3-45-04D-C6J1U 1SET SY3000 manifold model Ejector valve number Note 1) The combined total of solenoid valve and ejector valve stations is a maximum of 20 stations.

(The tightening torque of the M4 screw must be 1 to 1.2Nm.) 20 - < Applicable Auto switches > Solid state switch D-Y59A/BY69A/BY7P(V) D-Y7NW(V)Y7PW(V)Y7BW(V) D-Y7BAL Reed switch D-Z73Z76Z80 How to mount and move the auto switch Fig. 10 Attach the auto switch mounting bracket to the cylinder tie rod so that the bottom surface of the auto switch mounting bracket contacts the cylinder tube

Option Bracket J: With drain guide (Option) female thread T: With element service indicatior Maintenance space Drain Element service indicator Dimensions with mounting bracket Model Port size (Nominal size B) A B C D E F G H 10 10 10 10 10 10 10 10 10 I 56 66 66 80 80 90 90 100 150 J 15 20 17 22 19 25 21 30 40 K 5 8 8 8 8 10 10 10 15 L 9 12 12 14 14 14 14 16 20 M 5.5 6 6 7 7 9 9 9 11 N 35

Connect a suitable load. (2) Check that the impedance of the input equipment (A/D transformer) is suitable. 6 After energizing, the display and output can drift. For detecting fine pressures, warm up the product for 10 to 15 minutes. Check if the product satisfies the specified accuracy after 10 minutes warm up time.

/A8, D-A7H/A80H, D-A73C, A80C, D-C7/C8, D-C73C/C80C, D-E7A, E80A, D-Z7/Z8, D-9/9A, D-A9/A9V, D-A79W The auto switches above do not have a built-in contact protection circuit.

If it is 10 L/min, there is a flow of 10 L passing through the device in 1 minute. The voltage drop across the product (and therefore not applied to the load), when the switch output is ON. The voltage drop will vary with load current, and ideally should be 0 V.

Number of ejectors 1 to 10 Ejector mounting position U D U side D side [Example: When individual wiring type model 45 for SY3000 is selected] ZZY Y3-45-04D-C6J1U 1SET Note 1) The combined total of solenoid valve and ejector valve stations is a maximum of 20 stations. (Example: When there are 12 solenoid valve stations, there are 8 ejector stations.)

Configuration Minimum equipment and wiring requirements to get started 1 Provided by customer Ex) 200 V AC (*1) 7 Provided 6 1 by customer 8 2 3 N PC 1 2 5 9 C D 11 21 10 4 (*2) U 2 Electric Actuators Ex) LEF V W Provided by customer 3 PLC (CC-Link master unit) 11 (*1) Refer to LECSC Operation Manual, Chapter 4 for further details if the power supply voltage is 100VAC. (*2) When wiring to

A B C D E F G H LAT3-10 10 49 4 60 50 4 10.5 LAT3-20 20 69 6 25 90 80 14 20.5 LAT3-30 30 89 6 25 120 110 24 30.5 13 - LAT3-50 Note 1) Refer to Mounting screw specifications and tightening torques in section 4.3 Mounting (P.24). Note 2) The length of the part of the dowel pin inserted into the positioning hole should be shorter than the specified depth.

Note 2) This filter does not include any companion flange, companion flange bolt, and O-ring. 4 x K depth L DRAIN (): Internal dimensions for FH342 type (mm) Model Weight (kg) d A B C D E F G H J J' K L M N P Q Threaded Rc Flange SSA FH340-03 FH340-04 FH342-06 FH342-08 FH34 -10 FH34 -12 FH341-16 FH440-03 FH44 -04 FH44 -06 FH44 -08 FH44 -10 FH44 -12 FH441-16 FH441-20 FH441-24 FH540-03 FH54

For single power supply use COM D COM D is receiving data: Lights up 2 COM D is having no data to receive: Goes off 1: Refer to "Operation Manual" for the extension diagnosis information. 2: It is lit when input unit is connected and communicating normally.

CN2: TB/PC connector.31 9. 1 How to use.31 10. LED display.32 10. 1 LED display.32 10. 2 Controller IF communication status and LED display.33 11. Mode.34 11. 1 Outline.34 11. 2. Step data input mode .34 11. 3. Numerical data input mode.34 11. 4. Data writing mode.36 12.

60 40 1 AC DC AC/DC Maximum 10 (1) 5 (2) Minimum Note 1) Dew point is below 10C Note 2) Below 50 cSt Note 3) D, E, N, P, etc. in parentheses represents option symbol.

Thread symbol SYMBOL DRAIN TUBE SIZE NONE 10mm UNIT : inch (mm) N 3/8 DRAFT AIR OUTLET B Q E D A SWITH WITH LAMP AIR OUTLET EVAPORATION THERMOMETER AIR INLET F G DRAIN SEPARATOR VENTILATION C VENTILATION VENTILATION TERMINAL BLOCK DRAIN TUBE (O.D.10 LENGTH:0.8m) (820) J K L P N M H 4-13 POWER CABLE WITH PLUG (L=2800) Dimensions (inch [mm]) Model Thread Size A B C D E F G H J K L M N P Q IDFB3E

M9NWV D-M9NWV A93V D-A93V M9PV D-M9PV M9PWV 2 D-M9PWV A96V D-A96V M9BV D-M9BV M9BWV D-M9BWV A72 D-A72 F9G D-F9G F79W D-F79W A73 D-A73 F9H D-F9H F7PW D-F7PW A80 D-A80 F79 D-F79 J79W D-J79W A72H D-A72H F7P D-F7P F7NWV D-F7NWV A73H D-A73H J79 D-J79 F7BWV D-F7BWV A76H D-A76H J79C D-J79C M9NA D-M9NA A80H D-A80H F7NV D-F7NV M9PA D-M9PA A73C D-A73C F7BV D-F7BV M9BA D-M9BA A80C D-A80C F7PV