[1] Power supply input terminals, L1, L2: Provide specified power supply to input terminals L1 and L2. [2] Connect the motor input terminal (U, V, W) to the driver power terminal (U, V, W).

Volume of fluid in tank: 200 L 2. Pump-out volume: 100 L/min 3. Contaminant concentration of used fluid: 500 ppm (initial concentration, percentage by volume) 4. Number of separators: 2 pcs.

Actuator driving system Inside of clean room w t e q r t q Cylinder relief port piping w Solenoid valve exhaust piping e Breathing piping of regulator r Drain piping t Exhaust Cleaner for Clean room/AMP series Cylinder relief port piping Series 10-/12-/21(atmospheric release type) Connect the relief port piping with the dedicated duct piping installed outside the clean room or with the exhaust

5 w !3 EA EA y A A P P r q B EB B !7 EB !4 !1 !2 t Component Parts Aluminum alloy NBR Note No. 10 Description Material No.

How to order L E C C G 2 L Cable length K 0.3m L 0.5m 1 1m ii. Dimensions (4) Branch connector i. How to order L E C C G D Branch connector ii. Dimensions (5) Terminating resistor i. How to order L E C C G R ii. Dimensions 40 8.

IDX-OM-W034-B PRODUCT NAME Refrigerated Air Dryer MODEL / Series IDFB22E-11 IDFB22E-11 K,R,S,T,V IDFB22E-23 IDFB22E-23 K,R,T,V IDFB37E-23 IDFB37E-23 K,R,T,V IDFB55E-46 IDFB55E-46 L,R,T,V IDFB75E-46 IDFB75E-46 L,R,T,V This manual is intended to explain the installation and operation of the product.

L L 2 ISA-19-2 139 3 ISA-19-3 177 4 ISA-19-4 215 5 ISA-19-5 253 6 ISA-19-6 291 M12 connector no. Pin no.

at a flow volume of 1000 l/min (ANR), the inlet pressure will be 0.05 MPa.

L ZY O L ZF G H F ZP K J SP ZCUK B C E D I A 2 x 4.5 AMJ AMV AEP HEP Related Equipment A B C D E F G H I J K L Model ZFC050-02 ZFC050-23 ZFC050-04 ZFC051-01 ZFC051-03 58.5 12.75 12.75 2 3.2 33 25 10 10.5 10.5 12 8.5 13.75 4 58 12.5 12.5 1/8" 5/32" ZFC100-04 4 ZFC100-06 6 30 10 18 11.6 19.5 23 20 29 53.2 9.1 14.1 ZFC101-03 5/32" ZFC101-07 1/4" ZFC200-06 6 ZFC200-08 8 34 14 22 15.6 23.1 27

(ANR)) 4B 1B B AMF250 AMF650 AMF1000 1 4 0.1 MPa 0.1 MPa 0.1 MPa Pressure drop (MPa) Pressure drop (MPa) Pressure drop (MPa) Max. flow line Max. flow line Air flow rate (l /min (ANR)) Air flow rate (m3/min (ANR)) Air flow rate (l /min (ANR)) 2B AMF350 AMF800/801 B 3 8 0.1 MPa 0.1 MPa Pressure drop (MPa) Pressure drop (MPa) Max. flow line Air flow rate (m3/min (ANR)) Air flow rate (l /min

Dimensions for installation L: Dimensions n: Number of stations L n 2 3 4 5 6 7 8 9 10 L1 133.4 166.4 199.4 232.4 265.4 298.4 331.4 364.4 397.4 L2 117 150 183 216 249 282 315 348 381 -11No.EX-OMY0021 Wiring Select the appropriate cables to mate with the connectors mounted on the SI unit.

L 100mm, or stroke 1 2 1 7 5 4 6 2 6 5 7 3 L L 8 Fig 6. Position for application of grease Table 7. Amount of grease units: g Stroke 40 50 63 80 100 P o s i t i o n f o r Bore g r e a s e At 100st 3 to 4 3 to 5 4 to 5 6 to 8 8 to 10 50st added 1 1 1.5 2 3 16 3-2-4. Mounting of seals 1) Rod seal, Cushion seal (Fig 6, ) Pay attention to the mounting direction of the seal.

Serial Number N "x" 4 0x0016 (22) 0 R Hardware Revision N HW-Vx.y 5 0x0017 (23) 0 R Software Revision N FW-Vx.y 5 (24) 0 R/W Application Specific Tag Y "* *" 6 0x0018 Refer to page 17 "Device State parameter" for details 0x0024 (36) 0 R Device State N Refer to page 17 "Detailed Device State parameter" for details 0x0025 (37) 1..8 R Detailed Device State N 1: Where R is Read and W is Write

AMX-OMZ0092 PRODUCT NAME Line Filter MODEL / Series / Product Number AFF50-(F,N)06 ~ (F,N)10(B,C,D)(-J,L,R,W,Z)-D AFF60-(F,N)10(B,C,D)(-J,L,R,W,Z)-D Contents Page 1. Safety Instructions 2 to 6 2. Application 7 3. Standard specifications 7 4. How to Order 8 5. Construction / Options / Replacement parts 9 6. Bowl assembly specifications 10 to 11 6-1. Bowl assembly for AFF50 10 6-2.

AMX-OMZ0093 PRODUCT NAME Mist Separator MODEL / Series / Product Number AM50-(F,N)06 ~ (F,N)10(B,C,D)(-J,L,R,W,Z)-D AM60-(F,N)10(B,C,D)(-J,L,R,W,Z)-D Contents Page 1. Safety Instructions 2 to 6 2. Application 7 3. Standard specifications 7 4. How to Order 8 5. Construction / Options / Replacement parts 9 6. Bowl assembly specifications 10 to 11 6-1. Bowl assembly for AM50 10 6-2.

AMX-OMZ0094 PRODUCT NAME Micro Mist Separator MODEL / Series / Product Number AMD50-(F,N)06 ~ (F,N)10(B,C,D)(-J,L,R,W,Z)-D AMD60-(F,N)10(B,C,D)(-J,L,R,W,Z)-D Contents Page 1. Safety Instructions 2 to 6 2. Application 7 3. Standard specifications 7 4. How to Order 8 5. Construction / Options / Replacement parts 9 6. Bowl assembly specifications 10 to 11 6-1.

Model D L M M M AKH03-00 AKH07-00 AKH09-00 AKH11-00 AKH13-00 3 6 10 17 24 2.8 6.5 14 24 34 5/32 1/4 5/16 3/8 1/2 9.3 12 15.2 18.5 21.7 33.5 39 53.3 63.6 70.2 12.7 13.6 18.5 21 22 L Male Connector Type: AKH Millimeter Size Connection thread R Applicable tube O.D.

Lead wire: 0.6 m) C W/suction filter (Mounting on ZX unit) M5 x 0.8 0X Connector type (Lead wire: 3 m) CL W/suction filter (Mounting on ZX unit) M6 x 1 (Option) 0XY Without connector Base mounting (Mounting on ZR unit) 0R CN Note) Single mounting type: M5 x 0.8 (female) threaded.

Cover A Case Cover A Case O L L Element O-ring Window 3) Pull cover A out of the case and remove the element. Remove dust and other debris remaining inside the case by blowing it out with air, etc.