NBR JIS B2401G35 1 pc. u 4.6-30 Series AMF Dimensions: AMF150 to AMF350 M Dimensions with mounting bracket Model Port size (Nominal size B) A B C D E F G H 146 167 167 198 198 I 56 66 66 80 80 J 15 20 17 22 19 K 5 8 8 8 8 L 9 12 12 14 14 N 35 40 40 50 50 O 54 66 66 80 80 P 70 84 84 100 100 Q 26 28 28 34 34 R 4.5 5 5 5 5 S 1.6 2.0 2.0 2.3 2.3 1/8, 1/4,3/8 1/4, 3/8 5.5 6 6 7 7 139 152 158 184
gauge (Option) OUT side gauge port Rc 1/8 IN side gauge port Rc 1/8 IN port Rc 3/8 139 43 46 15 Silencer (Option) OUT port Rc 3/8 21 24 EXH port Rc 3/8 53 4 x 12 98 3.2 73 118 (When silencer installed: 179) (When high-noise reduction silencer installed: 179) VBA42A-04 404 43 40 Pressure gauge (Option) IN side gauge port Rc 1/8 OUT side gauge port Rc 1/8 IN port Rc 1/2 62 62.8 172 Silencer
At least 40 mm of maintenance space is necessary for removing the bowl. Bolt Flange drop prevention stopper Stainless steel bowl Minimum maintenance space 40 mm It is possible to remove the bolts from the same direction (front). An element service indicator is fitted as standard. The new red ring is larger than the existing indicator, which improves visibility.
4B flange 20 2B flange 30 3B flange 40 4B flange Vessel shape Piping support type Self-standing type 60 6B flange Model Selection Max.
For precise pressure detection, allow the product to warm up for 10 to 15 minutes. Check if the product satisfies the specified accuracy 10 minutes after supplying power. Warming up inadequate Product failure Replace the product. -75No.PS-OMW0014-B Problem No.
For precise pressure detection, allow the product to warm up for 10 to 15 minutes. Check if the product satisfies the specified accuracy 10 minutes after supplying power. Warming up inadequate Product failure Replace the product. -75No.PS-OMW0005-C Problem No.
If the installation is using accurate control, wait until the product has warmed up (approximately 10 to 15 minutes).
If the installation is using accurate control, wait until the product has warmed up (approximately 10 to 15 minutes).
Grommet style L, M Plug connector Style 0.14 (0.008) 3 4 Standard SY11 0 to 0.7 N.C. 100kPa to 0.6 100kPa to 0 Large flow capacity 0.22 (0.012) SY1l3 (A): 13 SY1l4 (A): 24 SY1l3 (A): 15 SY1l4 (A): 26 3 4 0 to 0.7 SY11 A 100kPa to 0.6 100kPa to 0 N.C.
Orifice diameter [mm] Port size Valve type Orifice diameter [mm] Port size Valve type Orifice diameter [mm] Port size Valve type N.C. 1/4 to 1 10, 15, 20, 25 10, 15, 20, 25, 35, 40, 50 N.C./N.O. 1/4 to 50A 10 to 12 N.C.
If the rubber viscosity increases, replace the suction cup. 15) The product with energy saving switch reduces air consumption by stopping air supply by creating vacuum between the check valve and pad in the ejector while adsorbing the workpiece.
If the installation is using accurate control, wait until the product has warmed up (approximately 10 to 15 minutes).
MTS 0.7 20 35 55 79 141 0.6 17 30 47 68 121 0.5 14 25 40 57 101 0.4 11 20 32 45 80 0.3 8 15 24 34 60 28 50 79 113 201 With Shock Absorber Mass Standard Stroke (g) (mm) Body mass 80 105 100 160 130 210 210 320 640 830 Standard stroke 5, 10 10, 20 10, 20 15, 25 20, 30 Model MXP6 MXP8 MXP10 MXP12 MXP16 Model MXP6-5 MXP6-10 MXP8-10 MXP8-20 MXP10-10 MXP10-20 MXP12-15 MXP12-25 MXP16-20 MXP16-30
, 20, 25 10, 15, 20, 25, 35, 40, 50 N.C.
Options J: With drain guide T: With element service indicator Element service indicator Dimensions with mounting bracket Model Port size (Nominal size B) A B C D E F G H 10 10 10 10 10 10 10 10 10 I 56 66 66 80 80 90 90 100 150 J 15 20 17 22 19 25 21 30 40 K 5 8 8 8 8 10 10 10 15 L 9 12 12 14 14 14 14 16 20 M 5.5 6 6 7 7 9 9 9 11 N 35 O 54 66 66 80 80 88 88 102 136 P 70 84 84 100 100 110
2 NBR u 25 O-ring NBR 26 O-ring NBR w 27 O-ring NBR 28 Hexagon socket head plug Carbon steel 632 Series VCHR Direct Operated Regulator for 6.0 MPa (Relieving Type) Dimensions VCHR30 90 2 x Rc 1/4: with plug Set pressure detection port 2 x 10.5 60 Port size: G3/4, G1 56 ARJ 11 Max. 269 5 AR425 to 935 15 50 OUT IN AMR 103 43: G3/4 40: G1 ARM ARP 215.5 IR 80 IRV VEX1 Relief port SRH 11 SRP SRF
Response time 5 (EA) 1 (P) 3 (EB) Response time ms at 0.5MPa (72.5psi) Type of actuation 3 position pressure center SV1000 SV2000 SV3000 SV4000 (A) 4 (B) 2 2 position single 11 or less 25 or less 28 or less 40 or less 2 position double 10 or less 17 or less 26 or less 40 or less 3 position 18 or less 29 or less 32 or less 82 or less 5 (EA) 1 (P) 3 (EB) 4 position dual 3 port valve 15 or
High flow type (0 to 0.3 MPa) PV060 4A 40 For 4 stations 4 mounting screws (M2 x 27 L) and one gasket are included. PV060 3A 40 For 8 stations w Plate Assembly Part No. Stations Fitting Barb fitting One-touch fitting PV060-10-8A PV060-10-7A PV060-10-10A PV060-10-9A 4 stations Connector cable length 8 stations Nil 6 10 300 mm Barb fitting is included.
Option Bracket J: With drain guide (Option) female thread T: With element service indicatior Maintenance space Drain Element service indicator Dimensions with mounting bracket Model Port size (Nominal size B) A B C D E F G H 10 10 10 10 10 10 10 10 10 I 56 66 66 80 80 90 90 100 150 J 15 20 17 22 19 25 21 30 40 K 5 8 8 8 8 10 10 10 15 L 9 12 12 14 14 14 14 16 20 M 5.5 6 6 7 7 9 9 9 11 N 35
No.PF-OMH0003-F PRODUCT NAME 4-channel Flow Monitor (Remote type monitor unit) MODEL / Series / Product Number PF2A20# PF2W20# PF2D20# Table of Contents Safety Instructions 2 Model Indication and How to Order 9 Summary of Product parts 12 Definition and terminology 13 Mounting and Installation 15 Installation 15 Wiring 16 Outline of setting 19 List of outputs 20 Initialize mode 21 Default