10 to 60C (No freezing or condensation)Operating/Stored: 35 to 85% RH (No condensation)250 VAC for 1 minute between live parts and case2 M or more between live parts and case (at 50 VDC Mega)10 to 150 Hz at whichever is smaller of 1.5 mm amplitude or 20 m/s2 acceleration, in X, Y, Z directions, for 2 hours each (De-energized)100 m/s2 in X, Y, Z directions, 3 times each (De-energized)?
10 to 60C (No freezing or condensation)Operating/Stored: 35 to 85% RH (No condensation)250 VAC for 1 minute between live parts and case2 M or more between live parts and case (at 50 VDC Mega)10 to 150 Hz at whichever is smaller of 1.5 mm amplitude or 20 m/s2 acceleration, in X, Y, Z directions, for 2 hours each (De-energized)100 m/s2 in X, Y, Z directions, 3 times each (De-energized)?
10 to 60C (No freezing or condensation)Operating/Stored: 35 to 85% RH (No condensation)250 VAC for 1 minute between live parts and case2 M or more between live parts and case (at 50 VDC Mega)10 to 150 Hz at whichever is smaller of 1.5 mm amplitude or 20 m/s2 acceleration, in X, Y, Z directions, for 2 hours each (De-energized)100 m/s2 in X, Y, Z directions, 3 times each (De-energized)?
10 to 60C (No freezing or condensation)Operating/Stored: 35 to 85% RH (No condensation)250 VAC for 1 minute between live parts and case2 M or more between live parts and case (at 50 VDC Mega)10 to 150 Hz at whichever is smaller of 1.5 mm amplitude or 20 m/s2 acceleration, in X, Y, Z directions, for 2 hours each (De-energized)100 m/s2 in X, Y, Z directions, 3 times each (De-energized)?
10 to 60C (No freezing or condensation)Operating/Stored: 35 to 85% RH (No condensation)250 VAC for 1 minute between live parts and case2 M or more between live parts and case (at 50 VDC Mega)10 to 150 Hz at whichever is smaller of 1.5 mm amplitude or 20 m/s2 acceleration, in X, Y, Z directions, for 2 hours each (De-energized)100 m/s2 in X, Y, Z directions, 3 times each (De-energized)?
10 to 60C (No freezing or condensation)Operating/Stored: 35 to 85% RH (No condensation)250 VAC for 1 minute between live parts and case2 M or more between live parts and case (at 50 VDC Mega)10 to 150 Hz at whichever is smaller of 1.5 mm amplitude or 20 m/s2 acceleration, in X, Y, Z directions, for 2 hours each (De-energized)100 m/s2 in X, Y, Z directions, 3 times each (De-energized)?
10 to 60C (No freezing or condensation)Operating/Stored: 35 to 85% RH (No condensation)250 VAC for 1 minute between live parts and case2 M or more between live parts and case (at 50 VDC Mega)10 to 150 Hz at whichever is smaller of 1.5 mm amplitude or 20 m/s2 acceleration, in X, Y, Z directions, for 2 hours each (De-energized)100 m/s2 in X, Y, Z directions, 3 times each (De-energized)?
10 to 60C (No freezing or condensation)Operating/Stored: 35 to 85% RH (No condensation)250 VAC for 1 minute between live parts and case2 M or more between live parts and case (at 50 VDC Mega)10 to 150 Hz at whichever is smaller of 1.5 mm amplitude or 20 m/s2 acceleration, in X, Y, Z directions, for 2 hours each (De-energized)100 m/s2 in X, Y, Z directions, 3 times each (De-energized)?
cylinder Actuator unit Model Bore Cushion Piping (mm) 50 10 400 450 500 550 10 500 ralized piping Built-i on right side shock CY1F 15 750 on left side 25 1200
Output pressure (kPa) 40 0 0 Out 60 0.5 0.5 80 1.0 1 0 2 4 6 8 10 0 25 50 75 100 0 25 50 75 100 Input signal (%F.S.) Count Input signal (%F.S.)
or less, Temperature 40C or less Note 2) Deionized water Sodium hydroxide (Caustic soda) Concentration 50% or less Nitrogen gas Ultrapure water Sulfuric acid (except fuming sulfuric acid) Note 2) Concentration 30% or less Phosphoric acid Concentration 50% or less The material and fluid compatibility check list provides reference values as a guide only.
Seal kit includes a grease pack (20 to 50: 10 g, 63, 80: 20 g). Order with the following part number when only the grease pack is needed.
Rc3/8 14 12 25 220 25 140 60 60 R5 50 118 160 270 210 60 2 x M8 x 1.25 thread depth 13 (External cover mounting screw) 4 x 11 10.5 (Clamp block mounting hole) 4 x 13 through 18 4 x 26 counterbore depth 9 2 x 8H7 +0.015 0 118 14 (Mounting hole) 500.03 32 25 15 44 140 20 35 10 18 18 82 10.5 (Fully open) 46 204 211 19 118 480 2 W-R1/W-R3 Series Specific Product Precautions Be sure to read this
Input of the Set point 2 L/min, L CFM x 10-2, CFM x 10-1, ft3 x 10-2, ft3 x 10-1, gal(US)/min, gal(US) 1 Brown DC(+) Non-Reverse output Reverse output Refer to the product catalogue or SMC website (URL http://www.smcworld.com) for more information about panel cut-out dimensions.
(mm) (kg) (MPa) 6 CY3B6 1.0 0.55 10 CY3B10 2.7 0.55 15 CY3B15 7.0 0.65 20 CY3B20 11.0 0.65 Body Rotation moment 25 CY3B25 18.5 0.65 Fig. 6-1 Moment produced at stroke end 32 CY3B32 30.0 0.65 40 CY3B40 47.0 0.65 50 CY3B50 75.0 0.65 If the cylinder is kept operating in such a 63 CY3B63 115.0 0.65 condition, the wearing of external slider is Note) Operation of cylinder at pressure over worn
g, batteries 50 g) 2 pcs. of type AA dry batteries (manganese R6 or alkaline LR6) are not included.
Min.operating pressure (1) (1) 10 to 50C 10 to 50C Ambient and fluid temp.
SealKir 25, 30, 35, 40. 45, 50, 75, 100 25 30,35,4A, 45,50.75, tOD 25, 30, 35.40, 45, 50, 75, 100 .Ho{ to make interrediaie slroke rtrmediale stroke berwen 50-l0o (5s,60,65 ...) are obtained throlgh the use ol spaceB (5. 10, 1s,20mm) (Example) CDQBPSo-55 oMr S[4C would install a 20mrn width spacer in rire cDQ2Bp 50 750M. ll lool brackel is required, order 2 pcs/cylindef.
g, batteries 50 g) 2 pcs. of type AA dry batteries (manganese R6 or alkaline LR6) are not included.
x 1.5 M18 x 1.5 300 800 1250 3100 0.5 0.5 0.75 1 5 Semi-standard/Thread nominal size 0.5 0.5 0.5 0.75 0.75 0.75 1 1 300 800 800 1250 1250 1250 3100 3100 JC20-8-100 JC25-10-150 JC32-10-100 JC40-12-125 JC40-12-150 JC40-12-175 JC50-16-150 JC63-16-200 M8 x 1 M10 x 1.5 M10 x 1 M12 x 1.25 M12 x 1.5 M12 x 1.75 M16 x 1.5 M16 x 2 20 25 32 32/40 40 32/40 50 50/63 5 How to Order 14-150 JC 40 Thread