Cylinder (Tube) Inner Diameter(φ): 16, Stroke(mm): 200, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Double rod, Main Body Shape: Standard, Additional Function: Standard, Environment, Applications: Clean Room, Operating Temperature(°C): -, Cushion: Air cushion, Operating Pressure(MPa): 0.1 to 0.7, Specification: Built-in magnet, Auto Switches: C73, Lead
Cylinder (Tube) Inner Diameter(φ): 16, Stroke(mm): 200, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Single Rods, Main Body Shape: Standard, Additional Function: Standard, Environment, Applications: Standard, Operating Temperature(°C): -10~70, End Locking: No, Valves: No, Operating Pressure(MPa): 0.06~1, Cushion: Air cushion, Auto Switches: C80C, Lead Wire
Cylinder (Tube) Inner Diameter(φ): 16, Stroke(mm): 200, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Single Rods, Main Body Shape: Standard, Additional Function: Standard, Environment, Applications: Standard, Operating Temperature(°C): -10~70, End Locking: No, Valves: No, Operating Pressure(MPa): 0.06~1, Cushion: Air cushion, Auto Switches: M9P, Lead Wire
Magnet: D (Built-in), Series: J2, Mounting: D (Double Clevis), Bore Size: 16mm, Stroke: 200mm, Cushion: A (Air Cushion), Head Cover Port Location: Perpendicular to Axis, Pivot Bracket: None, Rod End Bracket: W (Double Knuckle Joint), Auto Switch: M9P--Solid State, Gen. Purpose, 3 Wire PNP, Horizontal, Lead Wire or Prewired Connector: SAPC (0.5m Cord Length, M8-3 Pin Connector), Number: 2
Magnet: D (Built-in), Series: J2, Mounting: D (Double Clevis), Bore Size: 16mm, Stroke: 200mm, Cushion: A (Air Cushion), Head Cover Port Location: Perpendicular to Axis, Pivot Bracket: N (Pivot Bracket not Assembled), Rod End Bracket: W (Double Knuckle Joint), Auto Switch: M9P--Solid State, Gen. Purpose, 3 Wire PNP, Horizontal, Lead Wire or Prewired Connector: SAPC (0.5m Cord Length, M8-3
Cylinder (Tube) Inner Diameter(φ): 16, Stroke(mm): 200, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Single Rods, Main Body Shape: Standard, Additional Function: Standard, Environment, Applications: Standard, Operating Temperature(°C): -10~70, End Locking: No, Valves: No, Operating Pressure(MPa): 0.06~1, Cushion: Air cushion, Auto Switches: C80C, Lead Wire
Cylinder (Tube) Inner Diameter(φ): 16, Stroke(mm): 200, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Single Rods, Main Body Shape: Standard, Additional Function: Standard, Environment, Applications: Standard, Operating Temperature(°C): -10~70, End Locking: No, Valves: No, Operating Pressure(MPa): 0.06~1, Cushion: Air cushion, Auto Switches: M9P, Lead Wire
Cylinder (Tube) Inner Diameter(φ): 16, Stroke(mm): 200, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Double rod, Main Body Shape: Standard, Additional Function: Standard, Environment, Applications: Clean Room, Operating Temperature(°C): -, Cushion: Air cushion, Operating Pressure(MPa): 0.1 to 0.7, Specification: Built-in magnet, Auto Switches: C73, Lead
Magnet: Built-in Magnet, Mounting: Rod Flange, Bore Size: 40mm, Port Thread: Rc, Stroke A: 25mm, Rod End Thread A: Male Rod End, Rod Boot A: None, +: +, Stroke B: 200mm, Cushion: Air Cushion, Rod End Thread B: Male Rod End, Rod Boot B: None, Pivot Bracket: None, Rod End Bracket: None, Auto Switch: M9B--Solid State, Gen. Purpose, 2 Wire, Horizontal, Lead Wire or Prewired Connector: 3m, Number
Designation Description 1 SV24 V +24 V for solenoid valve 2 SV0 V 0 V for solenoid valve 3 SI24 V +24 V for SI unit operation 4 SI0 V 0 V for SI unit operation 5 Unused The M12 connector cable has two types, SPEEDCON compatible and non-compatible.
Power and output connector pin numbers (on the lead wire) Wire colour Description Brown DC(+) Black OUT1 White OUT2 Grey Analogue output/External input Blue DC(-) -16No.PF-OMJ0018-F Internal circuit and wiring example PFM30 NPN (2 outputs) + Analogue (1 to 5 V) output type Max. 30 V, 80 mA Internal voltage drop: 1 V or less Analogue output: 1 to 5 V Output impedance: approx. 1 k PFM31 NPN
1.5 V (1.4V) 5 V Current output 4 mA 6 mA (5.6 mA) 20 mA The value in ( ) is when PF2W511 is used.
For example, when analogue output is 1 to 5 V, F.S. = 5[V] 1[V] = 4[V], (ref. 1%F.S. = 4[V] x 1% = 0.04[V]) F.S. (Full span, Full scale) H A function to store the accumulated flow value in the products internal memory. The flow value will be stored at a set time interval of either 2 or 5 minutes.
Connector pin numbers -18No.PS-OMM0005-J Internal circuit and wiring example Z/ISE10(F)Output specification -A NPN open collector 2 outputs Max. 28 V, 80 mA Residual voltage 2 V or less -B PNP open collector 2 outputs Max. 80 mA Residual voltage 2 V or less -C NPN open collector 1 output Max. 28 V, 80 mA Residual voltage 2 V or less Analogue voltage output Output impedance approx. 1 k -E
Designation Description 1 SI24 V +24 V for SI unit operation 2 SV24 V +24 V for solenoid valve 3 SI0 V 0 V for SI unit operation 4 SV0 V 0 V for solenoid valve : Recommended mating M12 5-pin socket, part no. EX500-AP00and PCA-1401804. (Refer to page 40) The M12 connector cable has two types, SPEEDCON compatible and non-compatible.
Reed switches Solid state switches D-F9N (V) D-A90 (V) D-F9NW (V) DC (+) Brown [Red] DC (+) Brown [Red] Contact protection box OUT () Brown [Red] Reed switch Main switch circuit Main switch circuit OUT Black [White] OUT Black [White] CD-P11 CD-P12 OUT ( ) Blue [Black] DC () Blue [Black] DC () Blue [Black] D-A93 (V) D-F9P (V) D-F9PW (V) DC (+) Brown [Red] DC (+) Brown [Red] Brown [Red] LED
ON: Red light emitting diode Indicator light Auto Switch Weight Table Unit: g D-F9N(V) D-F9P(V) D-F9B(V) Model Auto Switch Internal Circuits 0.5 7 7 6 lead wire length (m) D-F9N, F9NV 3 37 37 31 5 61 61 51 DC (+) Brown Main circuit switch Main circuit switch OUT Black Auto Switch Dimensions D-F9 Switch mounting screw M2.5 x 4l Slotted set screw DC () Blue 2 Indicator light D-F9P, F9PV 2.7
DIN type 5 pins Number Description Function Description Function 2 SW+ Number 1 Sensor power supply + Open 2 3 4 For solenoid valve +24 V 1 SV24V N.C. 2 1 VQC 3 For solenoid valve 0 V 2 SV0V SW 3 Sensor power supply Protective ground 3 PE SIGNAL 4 Sensor input signal 4 1 5 5 SQ
Note 2) Please contact SMC for details. 1 (100 V) 2 (200 V) 3 (110 V) 4 (220 V) 7 (240 V) 8 (48 V) 5 (24 V) 6 (12 V) AC Operating Fluid and Ambient Temperature DC Operating fluid temperature (C) Ambient temperature (C ) Temperature conditions Power source Water (Standard) Air (Standard) Oil (Standard) (D.E.N.P) (D.N) (3) (3) High temperature water High temperature oil 99 100 60 40 40 60
Max. voltage (with no load): 30Vrms (42.4V peak) or less Max. current: q 8A or less (including shorts), and w When controlled by a circuit protector (fuse) with the following ratings: No-load voltage (V peak) Max. current rating 0 to 20 [V] 5.0 100 Over 20 [V] and up to 30 [V] Peak voltage value (2) A circuit (class 2 circuit) with maximum 30Vrms (42.4V peak) or less, and a power supply