Specifications 2. Operating method or operation 2-1. Design Precautions 2-2. Selection 2-3. Mounting 2-4. Air supply 2-5. Piping 2-6. Operating environment 2-7. Lubrication 3. Maintenance 3-1. Precautions 3-2. Disassembly drawing 3-3. Tightening torque 3-4.
211 277 321 B 260 298 366 432 T 9 9 11 11 S 8 7 10 15 R 78 97 98 115 P 50 35 45 46.5 AL 1 4, 3 8 1 4, 3 8 144 166 188 230 182 215 281 325 21.5 18 16 18.5 37 37 42 42 3.2 3.2 4.5 4.5 32 40 48 56 28 37 37 44 51 61 66 81 103 121 131 161 10 10 70 70 264 302 370 436 100 120 130 160 180 210 246 290 AMR3000 AMR4000 AMR5000 AMR6000 1 4, 3 8, 1 2 1 4, 3 8, 1 2 1 2, 3 4 1 2, 3 4 3 4, 1 3 4, 1 Adapter
A 3 4 , 1 2 150 165 42.7 76.3 45 65 40 60 35 40 80 80 1 1 3 4 ALBA90-10 ALBA90-20 14-13-19
RY0F H ol d out put pressure 1 Set dependi ng on t he dat a of RY00RY0B 0 Set pressure i m m edi at el y bef ore com m uni cat i on abnorm al i t y Set t i ng w hen f act ory i s shi pped 1 2 1 2 1 2 3 4 5 6 7 8 9 10 1 2 3 4 5 6 7 8 9 10 OFF OFF OFF OFF OFF OFF OFF OFF OFF OFF ON ON 7 Pressure set t i ng and out put m oni t ori ng Pressure set t i ng can be done by sendi ng i nput dat a usi
Introduction. 1-1 1.1 Outline .1-1 1.1.1 List of Models Compatible with the SMC VLS software . 1-1 1.1.2 Product Configuration. 1-1 1.1.3 Major Features of the ECC-PNAL-PCS/WIN-E Software. 1-1 1.2 Definitions.1-2 1.3 Abbreviations.1-2 2. Installation . 2-1 2.1 Operating System Requirements.2-1 2.2 Installation.2-1 2.3 Uninstallation .2-1 2.4 System Configuration .2-2 3.
MPa 0 2 MPa PSE576 0 to 5 MPa 0 5 MPa PSE577 0 to 10 MPa 0 10 MPa -14No.PS-OMT0006-C Dimensions Lead wire and M12 connector ZS-37-A ZS-37-B Adapter with throttle ZS-31-X175 -15No.PS-OMT0006-C Revision history A: Contents revised in several places.
Communicated at 100 Mbps 1 1 Communicated at half duplex 1 0 1 Communication method 1 White/Orange 2 Orange 3 White/Green 4 5 6 Green 7 8 1 2 3 4 +Tx +Rx -Tx -Rx Communicated at full duplex 1 1 2 1 2 3 1 2 4 SW1 CAUTION indicates a hazard with a low level of risk which, if not avoided, could result in minor or moderate injury. Caution: 5 Cable color: Signal name Pin No.
Tank Size 1 = 1/2 Liter, 5 inch Tank Float Switch FS1 2 = 1 Liter, 10 inch Tank Caps are manufactured of reinforced polypropylene and are available with 1/4" or 3/8" NPT connections for light to medium duty applications.
Seal kit includes a grease pack (10 g). Order with the following part number when only the grease pack is needed. Grease pack part no.: GR-S-010 (10 g) Piston seal 2 Set of left nos. !3, !4, !5. Rod seal NBR 1 Gasket 1 61
Fluid: air, inert gas, Operating pressure range: 0.1 - 0.7MPa, Effective area mm 2 (Cv): metal seal 2.0 (0.11) - 12.6 (0.7); rubber seal 3.1 (0.17) - 16.2 (0.9), Coil rated voltage: 12, 24VDC; 100, 110, 200, 220VAC, Response time (ms) standard 1W, high pressure 1.5W: metal seal 25 or less; rubber seal 30 or less, Ambient and fluid temperature: -10 to 50 C, VALVE, BODY PORTED, DIN (DC
Fluid: air, inert gas, Operating pressure range: 0.1 - 0.7MPa, Effective area mm 2 (Cv): metal seal 2.0 (0.11) - 12.6 (0.7); rubber seal 3.1 (0.17) - 16.2 (0.9), Coil rated voltage: 12, 24VDC; 100, 110, 200, 220VAC, Response time (ms) standard 1W, high pressure 1.5W: metal seal 25 or less; rubber seal 30 or less, Ambient and fluid temperature: -10 to 50 C, VALVE, BODY PORTED, DIN, VALVE
Fluid: air, inert gas, Operating pressure range: 0.1 - 0.7MPa, Effective area mm 2 (Cv): metal seal 2.0 (0.11) - 12.6 (0.7); rubber seal 3.1 (0.17) - 16.2 (0.9), Coil rated voltage: 12, 24VDC; 100, 110, 200, 220VAC, Response time (ms) standard 1W, high pressure 1.5W: metal seal 25 or less; rubber seal 30 or less, Ambient and fluid temperature: -10 to 50 C, VALVE, BODY PORTED (DC
Fluid: air, inert gas, Operating pressure range: 0.1 - 0.7MPa, Effective area mm 2 (Cv): metal seal 2.0 (0.11) - 12.6 (0.7); rubber seal 3.1 (0.17) - 16.2 (0.9), Coil rated voltage: 12, 24VDC; 100, 110, 200, 220VAC, Response time (ms) standard 1W, high pressure 1.5W: metal seal 25 or less; rubber seal 30 or less, Ambient and fluid temperature: -10 to 50 C, VALVE, BODY PORTED (DC
Fluid: air, inert gas, Operating pressure range: 0.1 - 0.7MPa, Effective area mm 2 (Cv): metal seal 2.0 (0.11) - 12.6 (0.7); rubber seal 3.1 (0.17) - 16.2 (0.9), Coil rated voltage: 12, 24VDC; 100, 110, 200, 220VAC, Response time (ms) standard 1W, high pressure 1.5W: metal seal 25 or less; rubber seal 30 or less, Ambient and fluid temperature: -10 to 50 C, VALVE, BODY PORTED, DIN (DC
Fluid: air, inert gas, Operating pressure range: 0.1 - 0.7MPa, Effective area mm 2 (Cv): metal seal 2.0 (0.11) - 12.6 (0.7); rubber seal 3.1 (0.17) - 16.2 (0.9), Coil rated voltage: 12, 24VDC; 100, 110, 200, 220VAC, Response time (ms) standard 1W, high pressure 1.5W: metal seal 25 or less; rubber seal 30 or less, Ambient and fluid temperature: -10 to 50 C, VALVE, BODY PORTED, DIN (DC
Fluid: air, inert gas, Operating pressure range: 0.1 - 0.7MPa, Effective area mm 2 (Cv): metal seal 2.0 (0.11) - 12.6 (0.7); rubber seal 3.1 (0.17) - 16.2 (0.9), Coil rated voltage: 12, 24VDC; 100, 110, 200, 220VAC, Response time (ms) standard 1W, high pressure 1.5W: metal seal 25 or less; rubber seal 30 or less, Ambient and fluid temperature: -10 to 50 C, VALVE, BODY PORTED (DC
Fluid: air, inert gas, Operating pressure range: 0.1 - 0.7MPa, Effective area mm 2 (Cv): metal seal 2.0 (0.11) - 12.6 (0.7); rubber seal 3.1 (0.17) - 16.2 (0.9), Coil rated voltage: 12, 24VDC; 100, 110, 200, 220VAC, Response time (ms) standard 1W, high pressure 1.5W: metal seal 25 or less; rubber seal 30 or less, Ambient and fluid temperature: -10 to 50 C, VALVE, BODY PORTED, IP65 (DC
Fluid: air, inert gas, Operating pressure range: 0.1 - 0.7MPa, Effective area mm 2 (Cv): metal seal 2.0 (0.11) - 12.6 (0.7); rubber seal 3.1 (0.17) - 16.2 (0.9), Coil rated voltage: 12, 24VDC; 100, 110, 200, 220VAC, Response time (ms) standard 1W, high pressure 1.5W: metal seal 25 or less; rubber seal 30 or less, Ambient & fluid temperature: -10 to 50°C, VALVE, BODY PORTED (DC), VALVE,
Fluid: air, inert gas, Operating pressure range: 0.1 - 0.7MPa, Effective area mm 2 (Cv): metal seal 2.0 (0.11) - 12.6 (0.7); rubber seal 3.1 (0.17) - 16.2 (0.9), Coil rated voltage: 12, 24VDC; 100, 110, 200, 220VAC, Response time (ms) standard 1W, high pressure 1.5W: metal seal 25 or less; rubber seal 30 or less, Ambient & fluid temperature: -10 to 50°C, VALVE, BODY PORTED, DIN (DC), VALVE