Thread sizes range from M3 to 2 and are available in both inch (NPT) and metric R/Rc(PT)Large flow in-line style, Body sizes: 1/2, 3/4, 1, 1-1/4, 1-1/2, Port sizes: 1/4, 3/8, 1/2, 3/4, 1, 1-1/4, 1-1/2, 2, SPEED CONTROLLER, FLOW CONTROL, 15 lb
Thread sizes range from M3 to 2 and are available in both inch (NPT) and metric R/Rc(PT)Large flow in-line style, Body sizes: 1/2, 3/4, 1, 1-1/4, 1-1/2, Port sizes: 1/4, 3/8, 1/2, 3/4, 1, 1-1/4, 1-1/2, 2, SPEED CONTROLLER, FLOW CONTROL, 49 lb
Thread sizes range from M3 to 2 and are available in both inch (NPT) and metric R/Rc(PT)Large flow in-line style, Body sizes: 1/2, 3/4, 1, 1-1/4, 1-1/2, Port sizes: 1/4, 3/8, 1/2, 3/4, 1, 1-1/4, 1-1/2, 2, SPEED CONTROLLER, FLOW CONTROL, 49 lb
Thread sizes range from M3 to 2 and are available in both inch (NPT) and metric R/Rc(PT)Large flow in-line style, Body sizes: 1/2, 3/4, 1, 1-1/4, 1-1/2, Port sizes: 1/4, 3/8, 1/2, 3/4, 1, 1-1/4, 1-1/2, 2, SPEED EXHAUST CONTROLLER, FLOW CONTROL W/QUICK EXHAUST, 85 lb
Table 3.2-1 Amount of radiation and required ventilation Required ventilation amount (m3/min) Heat Differential temp. of Differential temp. of Model radiation 3 oC between inside and 6 oC between inside and (kW) outside of installation outside of installation area area HRL100-A-20 Approx.18 305 155 HRL200-A-20 Approx.35 590 295 HRL300-A-20 Approx.45 760 380 Installation environment specifications
Table 3.2-1 Amount of radiation and required ventilation Required ventilation amount (m3/min) Heat Differential temp. of Differential temp. of Model radiation 3 oC between inside and 6 oC between inside and (kW) outside of installation outside of installation area area HRL100-A-20 Approx.18 305 155 HRL200-A-20 Approx.35 590 295 HRL300-A-20 Approx.45 760 380 Installation environment specifications
Table 3.2-1 Amount of radiation and required ventilation Required ventilation amount (m3/min) Heat Differential temp. of Differential temp. of Model radiation 3 oC between inside and 6 oC between inside and (kW) outside of installation outside of installation area area HRL100-A-40 Approx.18 305 155 HRL200-A-40 Approx.35 590 295 HRL300-A-40 Approx.45 760 380 3.2 Installation HRL Series 3-6
Table 3-1 Amount of radiation and required ventilation Required ventilation amount (m3/min) Heat Differential temp. of 3 C between inside Differential temp. of 6 C between inside radiation Model (kW) and outside of and outside of installation area installation area HRR010-A-10/20Approx.2 40 20 3.2 Installation HRR Series 3-4 HRX-OM-X084 Chapter 3 Transport and Setting Up The water cooled
Table 3-1 Amount of radiation and required ventilation Required ventilation amount (m3/min) Heat Differential temp. of 3 C between inside Differential temp. of 6 C between inside radiation Model (kW) and outside of and outside of installation area installation area HRR012-A-10/20Approx.2 40 20 HRR018-A-10/20Approx.4 70 40 HRR024-A-10/20Approx.5 90 50 HRR030-A-10/20Approx.6 100 60 3.2 Installation
Table 3-1 Amount of radiation and required ventilation Required ventilation amount (m3/min) Heat Differential temp. of 3 C between inside Differential temp. of 6 C between inside radiation Model (kW) and outside of and outside of installation area installation area HRR050-A-20/40Approx.10 140 70 3.2 Installation HRR Series 3-4 HRX-OM-X071 Chapter 3 Transport and Setting Up The water cooled
HRS090 Series 2.1 Precautions for communication 2-1 HRX-OM-T004 Chapter 2 Contact input/output communication 2.2 Communication specification Table 2.2-1 DIO Communication specification Item Specification Connector type M3 terminal block Contact input Insulation method Photo coupler signal Rated input voltage DC24V Input voltage range DC 21.6V to 26.4V Rated input current 5mA TYP Input impedance
HRSH Series 2.1 Precautions for communication 2-1 HRX-OM-R028 Chapter 2 Contact input/output communication 2.2 Communication specification Table 2.2-1 DIO Communication specification Item Specification Connector type M3 terminal block Contact input signal Insulation method Photo coupler Rated input voltage DC24V Input voltage range DC 21.6V to 26.4V Rated input current 5mA TYP Input impedance
. <> () () 6080 D-M9A(V) M3M3 0.6 0.7Nm (M2.5) (M2.5)0.050.1Nm 56mm 1) (M2.5) 2) M3 BM5 12 - 13 - 3. 14 - 1) 2)1 (30) * *(NC=b )(D-M9E(V)) 15 - / 16 - 3. CM2-*Z 3-1. a) b GR-S-010(10g )GR-S-020(20g ) P18, 4.
Size 10 Size 15 P211070-10 P211090-10 Stainless Hexagon socket set screw Stainless 3 Hexagon nut steel 1 M3 3 steel 1 M33L Cross recessed round head screw Stainless Cross recessed round head screw Stainless 2 steel 2 M34L 2 steel 3 M312L Stainless Aluminum steel 1 1 Joint alloy 1 Chromated 1 Joint No. Description Material Qty Note No.
Bolt size for mounting on axial direction Bolt Size Mounting on the top Mounting at bottom Bolt Tap depth When using body tap When using body through hole 1 M30.5 3.5 M40.7 M3 2 3 M50.8 M4 7 M40.7 4.5 Table 6.
MHZ2-25 M61 5.9 10 MHZ2-32 M61 5.9 10 MHZ2-40 M81.25 13.7 13 Nm Lmm MHZ2-10 M30.5 0.69 5 MHZ2-16 M40.7 2.1 8 MHZ2-20 M50.8 4.3 10 MHZ2-25 M61 7.3 12 MHZ2-32 M61 7.9 13 MHZ2-40 M81.25 17.7 16 Nm MHZ2-10 M2.50.45 0.49 MHZ2-16 M30.5 0.88 MHZ2-20 M40.7 2.1 MHZ2-25 M50.8 4.3 MHZ2-32 M50.8 4.3 MHZ2-40 M61 7.3 D-Y59 D-Y69 D-Y7P 7 - 1. 2. 1. 2. 3. 8 - 3. 4. 10 2 16 2 1 <> : AS1211F-M3
. <> AS1211F-M3 AS1201F-M5 AS1000 AS1002F 2-4. 1. 2. 2. 4. 1. () 2. 5 3. 4. 5 10 2-5 1.
H 9 - 3-5. () P13P14P15 5 4 M6 85.8L 4 4 4 M3 27 17 10 - 3-6. M8 8 P .18 M8 8 () NPN PIN 1 +24V DC24V 2 3 4 5 ON/OFF 6 ON/OFF 7 8 GND DC0V M8 2 M8 1 11 - 3-7. Z Y Y X Z Z X X Y Z -0.4 -0.8 48.4 12 - 4 (www.smcworld.com) 4-1.
INP 1 INP ON 0.50 -35- 6.3 0.1mm [Nm] mm LEF16 M4x0.7 1.5 6 LEF25 M5x0.8 3.0 8 LEF32 M6x1 5.2 9 LEFS40 M8x1.25 12.5 14 A A mm) mm LEF16 M3 3.5 20 LEF25 M4 4.5 24 LEF32 M5 5.5 30 LEFS40 M6 6.6 31 40mm 6.4 6 /1000km /500 -36- 1. 2. 3. 1. 2. a. b. c. d.
Bolts Size Tightening torque (Nm) M3 0.6310% M4 1.510% M5 310% 8.Troubleshooting When a fault occurs during the operation, the corresponding alarm or warning is displayed.