COMMUNICATION PROCEDURE -2-1 3 COMMUNICATION FORMAT -3-1 3.1 TYPE OF MESSAGE -3-1 3.2 CONTENT OF COMMUNICATION -3-1 3.3 COMPOSITION OF REQUIRED MESSAGE (FROM MASTER TO THE PRODUCT) -3-2 3.4 COMPOSITION OF RESPONSE MESSAGE (FROM THE PRODUCT TO MASTER) -3-3 3.5 EXPLANATION OF CODE -3-4 3.6 CAUTIONS FOR COMMUNICATION -3-6 3.7 COMMUNICATION EXAMPLE -3-7 3.8 CONNECTION -3-9 3.9 IDENTIFICATION
MPa 0 to 100 kPa 0 to 1 MPa 0 to 101 kPa 0.1 to 0.45 MPa 0.1 to 0.4 MPa 20 to 101 kPa 101 to 101 kPa 0.1 to 1 MPa 0.4 to 10 MPa 0.5 to 15 MPa 100 to 100 kPa 0.1 to 1 MPa 0 to 1 MPa Voltage 12 to 24 VDC (Ripple 10% or less) 3% F.S. or less (5 to 40C) 3% F.S. or less (0 to 60C) 3% F.S. or less (0 to 60C) 3% F.S. or less (0 to 60C) 0.01 mm or less (0 to 60C) Temperature characteristics 3% F
Applicable model LVR20 LVR40 LVR50 03 3 x 2 LVR20 LVR40 LVR50 03 1/8" x 0.086" 04 4 x 3 05 3/16" x 1/8" 06 6 x 4 07 1/4" x 5/32" 10 10 x 8 11 3/8" x 1/4" 12 12 x 10 13 1/2" x 3/8" 19 19 x 16 19 3/4" x 5/8" LQ3 Metric size Inch size Symbol Applicable tubing size Applicable model Symbol Applicable tubing O.D.
Description Material 1 Cover Stainless steel 304 4 Element 1 Stainless steel 304 EZH710AS-149 2 Bowl Stainless steel 304 NBR 1 JIS B 2401-1A-P185 3 V-band Stainless steel 304 5 O-ring 1 FKM JIS B 2401-4D-P185 Note Replacement Parts No.
G5-S CCVS2-G-S 45 80 86 35 18 35 25 1 36 17.5 88.2 72 98 1/2 148.5 57 103.9 101 CCVS3-G-S 45 80 86 35 18 35 25 1 36 17.5 88.2 72 98 1/2 148.5 57 103.9 101 CV CCVS0-S 45 80 86 35 25 36 17.5 88.2 72 98 1/2 57 CCVL02-G-S 66 107 116 50 24 40 28 1 40 27 115 100 3/4 62 180.5 124.9 135 MVGQ CCVL1-G-S 66 107 116 50 24 40 28 2 40 27 100 3/4 80 135 180.5 132.8 135 M6 x 1 10.5 to 12.5
Operating temperature (oC) 1 Fluoropolymer Tubing (PFA) Inch Size Series TILM RoHS Series Inch size Size Model Tubing size inch mm inch mm TILM01 1/8" x 0.086" 1/8" TILMB01 1/8" x 1/16" 1/8" TILM05 3/16" x 1/8" 3/16" 4.75 1/8" 3.15 TILM07 1/4" x 5/32" 1/4" 6.35 5/32" 3.95 TILM11 3/8" x 1/4" 3/8" 9.53 1/4" 6.33 TILM13 1/2" x 3/8" 1/2" 12.7 3/8" 9.5 TILM19 3/4" x 5/8" 3/4" 19.05 5/8" 15.85
4 20 Round head no.0 Philips screw 1 19 Bearing 1 High precision type:2 (angular duplex bearing) 18 Bearing 1 17 Piston seal 4 16 Wear ring 4 15 Magnet 2 14 Bearing retainer 1 13 Table 1 12 GasketEnd cover 1 11 GasketCover 1 10 Push nut 2 9 Shock absorber holder 1 8 Arm 902 pcs. 1801 piece 7 Pinion 1 6 Piston 2 5 End cover 1 4 Seal 1 3 Plate 1 2 Cover 1 1 Body 1 No Description Qty Note 21
Tube I.D.: 5 mm 5 5 4 4 Discharge time [s] Discharge time [s] 3 3 0.05 MPa 0.05 MPa 2 2 0.1 MPa 0.3 MPa 1 1 0.1 MPa 0 0 0 100 200 300 400 500 0 100 200 300 400 500 Tube length [mm] Tube length [mm] Maximum operating pressure is 0.1 MPa. Note 1) Maximum operating pressure is 0.3 MPa. Note 1) Note 1) Refer to Cautions when using the IZN10-11(female threads for piping) on page 448.
Setting of DIP switch for temporary stop. 1) DIP switch setting Change the DIP switch as shown below. 1 2 3 Operating conditions: OFF ON OFF Temporary stop Fig. 16 II.
These flow rate characteristics are for fresh water (viscosity 1 mPas, specific gravity 1.0). 2. Flow characteristic is measured based on necessary minimum piping. 3.
NPN (1 output) + Analogue (1 to 5 V) type PF2A7H--28NPN (1 output) + Analogue (4 to 20 mA) type PF2A7H--29Max. 30 V, 80 mA Internal voltage drop: 1 V or less 28: Analogue output: 1 to 5 V Output impedance: 1 k 29: Analogue output: 4 to 20 mA Max.
ZP2VB6-05 Workpiece Not gripped 1 cup gripping 2 cups gripping 3 cups gripping -47No.
When operating multiple cylinders with the auto switch in parallel, separate the cylinders, maintaining a minimum separation distance of at least 40 mm. 3. Maintenance 3-1. Inspections 3-1-1. Daily Check 1) Smoothness of the operation 2) Changes in piston speed and cycle time 3) Smooth movement of the slide table for the entire stroke 3-1-2.
: Manipulating industrial robots -Safety JIS B 8370: JIS B 8361: JIS B 9960-1: 1 JIS B 8433-1993: *2) 1. 2. 3. 1. 2. 3. 4. 2 VFR3000-OMJ0001-A / / / / 1 1 1 1 1 1 1 1.5 .5 .5 .5 *3) *3) *3) *3) 1 1 1 1 1 1 1 1 () 3 VFR3000-OMJ0001-A VFR3000 VFR3000 VFR3000 VFR3000 Series Series Series Series 5 5 5 5 / / / / / / / / () ( ) () 1 DC 3 3 () 3 EXH (VVFS3000-R-03-12 ( ( ( ( ) ) ) ) 0.1
0.49 0.47 0.47 0.14 0.14 0.15 0.15 2.0 2.0 1.9 1.9 Body ported Base mounted (With sub-plate) 2 position 1/8 Body side M5 x 0.8 3 position 1/8 1/4 1/8 1/4 1/8 1/4 1/8 1/4 1/8 1/4 1/8 1/4 1/8 1/4 1/8 1/4 0.54 0.19 2.2 0.56 0.23 2.4 Sub-plate side Single 0.54 0.19 2.2 0.56 0.23 2.4 Body side 2 position 0.54 0.19 2.2 0.56 0.23 2.4 Sub-plate side Double 0.54 0.19 2.2 0.56 0.23 Body side 2.4 M5
N.C. 3 2 1 300 13 16 5.5 2 x 2.8 UL1007 AWG22 4.5 16.5 For LVM12R 57 2 x 2.7 Mounting hole Push type Manual override N.O. N.C. 3 2 1 N.O.
Confirm there is air leakage. 1-2) Caught gasket Replace with new gasket. 1-3) Intrusion of foreign matter To remove foreign matter by air blow of piping and when a gasket damaged, replace with new gasket. 2. Air leaks through One-touch fitting 2-1) Tube is not inserted enough deeply. 2-2) Tube has a flaw. 2-3) Tube is cut diagonally.
Seals of CJ2-*Z series cannot be replaced. 3-1.
Confirm there is air leakage. 1-2) Caught gasket Replace with new gasket. 1-3) Intrusion of foreign matter To remove foreign matter by air blow of piping and when a gasket damaged, replace with new gasket. 2. Air leaks through One-touch fitting 2-1) Tube is not inserted enough deeply. 2-2) Tube has a flaw. 2-3) Tube is cut diagonally.
When 1 digit = 1 kPa, the pressure is given with an increment Digit (Min. setting unit) of 1 kPa, e.g., 1, 2, 3,, 99, 100. E Energy saving automatic control Indicate that the vacuum pressure during adsorption is monitored and ON and OFF of the ejector is automatically controlled.