(B) 2 (A) 4 Symbol 1 (P) 3 (R) Flow Rate Characteristics C [dm3/(sbar)] b Cv C [dm3/(sbar)] b Cv 14/2(PA/B) 4/25/3(A/BEA/EB) Flow rate characteristics Port size Valve model Body ported 10-VQD1121(V)-L M-M5 10-VQD1121 -L M-M5 10-VQD1151(V)-L M-M5 10-VQD1151W-L M-M5 0.05 0.07 0.06 0.07 Base mounted (With sub-plate) 0.19 0.28 0.22 0.27 0.31 0.28 0.31 0.28 0.22 0.27 0.22 0.27 0.16 0.24 0.10 0.25
Lead wire length 0.5 m Nil (Example) A73C 3 m L (Example) A73CL 5 m Z (Example) A73CZ None N (Example) A73CN D-P5DWL is available for 40 to 100. In addition to the models in the above table, there are some other auto switches that are applicable.
Length per roll Color Translucent Translucent Symbol N N R BU B N N N N N KM 10 m Red (Translucent) KF 20 m Blue (Translucent) Black (Opaque) Translucent Translucent Translucent Translucent Translucent Roll M 50 m 100 m 16 m ( 50 ft) H/DL L/LL 33 m (100 ft) 2 m Straight KC Metric O.D. size 3.2 O.D. 5/32" is available in 4 metric tubing, and O.D. 5/16" is available in 8 metric tubing.
Inch Size H (Hexagon width across flats) Connection thread NPT Effective area (mm2) Weight (g) A
Symbol Name PA06 CMX Electronic gear numerator 1 0 to 65535 PA07 CDV Electronic gear denominator 1 1 to 65535 Set the values as follows. 1 [PA06] M = 1000 [PA07] Actuator lead (L) [mm] n1/n2 M : [Servo motor resolution : 262144(Pulse/rev)] n1/n2: Pulley ratio *1 EX.)
If the minimum setting unit is 1 L/min, the display will change in 1 L/min steps, e.g. 10..11..12 L/min. M Minimum setting unit O Operating fluid temperature Range of fluid temperature that can be used by the product.
HEC-OM-S008 First edition Aug.2014 Rev1.2 May.2017 C Co om mm mu un ni ic ca at ti io on n M Ma an nu ua al l THERMO-CON Model No. HECR series Keep available whenever necessary.
Lead wire length symbols: 0.5 m Nil (Example) Y59A 3 m L (Example) Y59AL 5 m Z (Example) Y59AZ Solid state auto switches marked with are produced upon receipt of order. Auto switches are shipped together (not assembled).
L (Example) F8NL 5 m . Z (Example) F8NZ Auto switches marked with u are produced upon receipt of order.
) / CAN_L Low FG(DRAIN) VDeviceNet T T T 6m T T DataRate 500kbps 100 m 6 m 39 m 250kbps 250 m 78 m 125kbps 500 m 156 m 100 m 121 1%(1/4 W) DeviceNet AWG18 (0.82 mm 2) AWG15 (1.65 mm 2) AWG24 (0.20 mm 2) AWG22 (0.33 mm 2) 120 10%(1 MHz) 120 10%(1 MHz) 1.36 ns/ft(max.) 1.36 ns/ft(max.) 0.13 db/100 ft@125 kHz(max.) 0.25 db/100 ft@500 kHz(max.) 0.36 db/100 ft@1 MHz(max.)
_OUT2 6 N.C. 5 N.C. 4 White CH1_OUT2 3 Black C/Q (CH1_OUT1) 2 Blue L 1 Brown L+ 4 Black: 3 Blue: L C/Q (CH1_OUT1) 100 42.5 Front protection cover + Panel mount adapter 53 55 or more 47 37.5 +0.1 0.2 (2) 9.4 42.4 46.4 55 or more 4 x R1 or less Front protection cover Panel mount adapter Panel Waterproof seal m48 conversion adapter + Panel mount adapter (2) 6 1.5 48 Panel fitting dimensions
x J U U D T C 60 G P A H L B Dimensions (mm) Maximum operating tensile and compressive force (N) Center of Maximum screw-in depth P Allowable eccentricity U Applicable bore size Model M A B C D E F K L T J G H Weight (kg) Nominal size Pitch sphere R 180 JAL180-40-150-X530 40 1.5 220 116 55 96 74 48 151 90 89 22 28 70 78 49 3 55000 10.3 200 JAL200-45-150-X530 45 1.5 220 116 55 96 74 48 151
(2-color indicator) 2-wire 12 V 24 V Grommet Yes Relay, PLC 3-wire (NPN) 3-wire (PNP) IC circuit 5 V, 12 V 2-wire 12 V 3-wire (NPN equivalent) Reed auto switch 5 V Z76 IC circuit Yes Grommet 100 V Z73 IC circuit Relay, PLC 24 V 12 V 2-wire Z80 100 V or less Lead wire length symbols: 0.5 m Nil (Example) Y7BW 3 m L (Example) Y7BWL 5 m Z (Example) Y7BWZ Solid state auto switches marked
Lead wire length symbols: 0.5 m Nil (Example) M9NW Solid state auto switches marked with v are produced upon receipt of order. 1 m M (Example) M9NWM 3 m L (Example) M9NWL 5 m Z (Example) M9NWZ For details about auto switches with pre-wired connector, refer to the WEB catalog or Best Pneumatics.
and switching valve to pad by piping system Q2 = S x 11.1 l/min (ANR) Q : Smaller one between the Q1 and Q2 l/min (ANR) S : Effective area of piping (mm 2) Adsorption flow (l/min (ANR)) Air consumption (l/min (ANR)) Vacuum pressure Selection Procedure Tubing length (m) Air consumption From the point at which the valve's effective area of 18 mm 2 and the piping volume of 5 l intersect, the
.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com VZS VFS VS4 VQ7 EVS Large capacity EVS7-6 (Size 1) 1200 l/min (ANR) EVS7-8 (Size 2) 3000 l/min (ANR) EVS7-10 (Size 3) 5500 l/min (ANR) VFN Cylinder driving size Flow rate 100 160 200 Rubber seal, single type Lightweight Size 1 (3 position): 0.55 kg Size
(d) 4 mm Tube piping length l : 5 m Supply air pressure : 0.3 MPa Supply air dew point : 20C (Atmospheric pressure dew point) Ambient environment: Temperature 25C, Humidity 60% (1) Find the necessary length L from the length selection chart at basic conditions and Kv value.
3/min(ANR) 5.3 m 7.2 GWP (GWP) GWP Regulation (EU) No 517/2014 Regulation EU No 517/2014 (IPCC AR4 ) IPCC AR4 R410A 2,088 2,090 R410A 2,088 2,090 1 2 []: https://www.smcworld.com/products/ja/freon/ IDF60/70/80/90 Series 7-2 N M L O K H IDX-OM-W093 7.3 Port size Compressed air inlet Compressed air outlet Port size A B E D G F C P J M N O L K H mm A B C D E F G H J K L M N O P IDF60
3150 L/min 60 to 6300 L/min 120 to 12600 L/min Set point range Accumulated flow 0 to 999,999,999,990 L Instantaneous flow 2 L/min 5 L/min 10 L/min Flow Minimum resolution Accumulated flow 10 L 100 L Accumulated volume per pulse (Pulse width = 50 msec.)
(Circuit example) 0V 24VDC The stop is released switch Ry Stop Switch U Surge suppressor Ry: Relay Power supply plug 1 LK RLS (6) Ry (3) EMG (2) M 24V (1) C 24V Controller 0V (4) Input power 24VDC supply 0V Power supply plug 2 Ry (3) EMG LK RLS (6) (2) M 24V (1) C 24V Controller 0V (4) Input power 24VDC supply 0V Power supply plug 3 LK RLS (6) Ry (3) EMG (2) M 24V Controller (1) C 24V 0V