Body Size: 20 (Applicable AC Size: AC20), Handle Operation: Single Action, Thread Type: Rc, Port Size: 01 (1/8), Mounting: without Mounting Option, Silencer: without Silencer, Handle Color: Red, Handle Material: M (Metal), Flow Direction: Flow Direction: Left to Right), Unit: Unit of Product Label: MPa
Body Size: 20 (Applicable AC Size: AC20), Handle Operation: W (Double Action), Thread Type: Rc, Port Size: 01 (1/8), Mounting: without Mounting Option, Silencer: without Silencer, Handle Color: Red, Handle Material: M (Metal), Flow Direction: Flow Direction: Left to Right), Unit: Unit of Product Label: MPa
Rated Vacuum Range: F (-100 to 100 kPa), Output Specification: R (NPN Open Collector 2 Outputs + Analog Voltage Output), Unit Specification: M (SI Unit Only), Piping Specification: 01 (R 1/8)
Rated Vacuum Range: -101 to 0 kPa, Output Specification: V (PNP Open Collector 2 Outputs + Analog Current Output), Unit Specification: M (SI Unit Only), Piping Specification: 01 (R 1/8)
Rated Vacuum Range: F (-100 to 100 kPa), Output Specification: Y (PNP Open Collector 2 Outputs + Copy Function), Unit Specification: M (SI Unit Only), Piping Specification: 01 (R 1/8)
Rated Vacuum Range: -101 to 0 kPa, Output Specification: X (NPN Open Collector 2 Outputs + Copy Function), Unit Specification: M (SI Unit Only), Piping Specification: 01 (R 1/8)
Rated Vacuum Range: -101 to 0 kPa, Output Specification: Y (PNP Open Collector 2 Outputs + Copy Function), Unit Specification: M (SI Unit Only), Piping Specification: 01 (R 1/8)
Rated Vacuum Range: -101 to 0 kPa, Output Specification: R (NPN Open Collector 2 Outputs + Analog Voltage Output), Unit Specification: M (SI Unit Only), Piping Specification: 01 (R 1/8)
Output Specification: T (PNP Open Collector 2 Outputs + Analog Voltage Output), Unit Specification: M (SI Unit Only), Piping Specification: 01 (R 1/8)
This is a legacy product. Please contact us for the latest version.sales@ocaire.com
Rated Vacuum Range: -101 to 0 kPa, Output Specification: T (PNP Open Collector 2 Outputs + Analog Voltage Output), Unit Specification: M (SI Unit Only), Piping Specification: 01 (R 1/8)
Function: 1 (Normally Closed), Piping: 2 (Body Ported), Body Option: M (Common EXH), Specifications: Standard, Voltage: 5 (24VDC), Lead Wire: M (M Plug Connector w/Lead Wire 0.3m), Surge Suppressor: Z (Light & Surge Suppressor), Manual Override: Non-locking Push Style, Port Size: 01 (Base Mounted w/Sub-plate 1/8, Body Ported 1/8), Thread: Rc, Bracket: F (Bracket)
Compressed air 1.0 MPa Fluid Max. operating pressure Min. operating pressure 0.05 MPa 1.5 MPa Proof pressure Ambient and fluid temperature Filtration degree Element life 5 to 60C 3 m (95% particle size collection) 2 years (1 year for A type) or when pressure drop reaches 0.1 MPa 0.1 MPa (N.O. type) or 0.15 MPa (N.C. type) in the case of types with auto-drain.
M Dimensions with mounting bracket Model Port size (Nominal size B) A B C D E F G S 6.0 , 2 H 463.5 I 180 J 30 K 15 L 24 N 120 O 184 P 220 Q 110 R 18 460.5 AMG850 1 2 13 42 348 220 57.5 220 10 14-20-7
10 to 60C (No freezing or condensation)Operating/Stored: 35 to 85% RH (No condensation)1000 VAC for 1 minute between live parts and case50 M or more between live parts and case (at 500 VDC Mega)10 to 150 Hz at whichever is smaller of 1.5 mm amplitude or 20 m/s2 acceleration, in X, Y, Z directions, for 2 hours each (Non-energized)100 m/s2 in X, Y, Z directions, 3 times each (Non-energized
When [M] is included in the controller model number the controller displays [S_J]. When [M] is not included in the controller model number the controller displays [S_F]. Hysteresis mode ON OFF Power on Specifications Outline with Dimensions (in mm) n_1 High pressure Wiring Normally closed mode Detects pressure displays values and performs switching.
PF-OMK0003CN-E 11.5mm , , , , IN 500kPa /KQ2 mm KQ2H04-M5 KQ2S04-M5 4 M50.8 KQ2L04-M5 /KJ mm KJH04-M5 KJS04-M5 4 M50.8 KJL04-M5 /M mm 4 M-5AN-4 M50.8 6 M-5AN-6 -16No. PF-OMK0003CN-E FG DC(+) OUT() DC(-) 15V 1k -17No. PF-OMK0003CN-E DC(+)DC(+) (OUT1) IN (20 ) -18No.
Length of communication cable for RS-485 shall be limited to around 500[m] in total, and that for RS232C shall be 15[m].
(A red color spot indicates the replacing time.) 5 to 60C 0.01m(95% particle size collection ) Oil mist removal rate Less than 3.5 particles 0.3 m or larger per liter of air ( 100 particles or less per cubic foot) Element Color Indicator (When element becomes saturated with oil the element surface changes from white to red.)
8000 AMF801 24000 AMF901 Model Rated flow (l/min (ANR)) Port size (Nominal size B) 2B Flange Weight (kg) 40 2B/3B/4B Flange 120 Specifications Compressed Air 1.0MPa Fluid Max. operating pressure Min. operating pressure Proof pressure Ambient and fluid temperature 0.05MPa 1.5MPa 5 to 60C Filtration rating 0.01m(95% particle size collection) Oil mist removal rate Less than 3.5 particles 0.3 m