SMC Corporation of America
Elite Part Number Search
Search Results "VFM351-02-01"

For Water 30 20 VX2 60-02 10 VX234.5 VX2 46 VX2 6010 VX2 50 8 3 2 04 03 3 2 3 2 VX223 10 3 2 VX2112 5 4 3 Flow rate Q l/min 2 1 0.001 (0.0018) (0.0054) 0.01 (0.017) 0.05 (0.07) 0.1 Pressure differential P = (P1 P2) MPa How to read the graph When a water flow of 2 l/min is generated, lP 0.017 MPa for a valve with 3 orifice (VX212, 222, 232).

Tap water: Standard of The Japan Refrigeration And Air Conditioning Industry Association (JRA GL-02-1994) Deionized water: Electric conductivity 1 S/cm or higher (Electric resistivity 1 Mcm or lower) 2 q Ambient temperature: 32C, w Circulating fluid: Tap water, e Circulating fluid temperature: CH1 20C/CH2 25C, r Circulating fluid flow rate: Rated flow, t Power supply: 200 VAC 3 q Ambient

Bore size Applicable series 02 03 04 06 10 12 14 20 Note 1) AS800 is available as special.

series 02 03 04 06 10 12 14 20 Caution L (2) Note 1) AS800 is available as special.

Lightweight, point-of-use ZH and ZU series vacuum generators combine design simplicity with high performance. Simply plug an air supply tube in one end, and vacuum is ready at the other end. The slim ZU generators are extra compact. The ZH and ZU immediate response may be quicker than central vacuum systems. Also, these generators are often smaller and lighter than the bulky vacuum lines

This is a legacy product. Please contact us for the latest version.sales@ocaire.com, VACUUM EJECTOR, VACUUM SERIES, ZH VACUUM EJECTOR, DC, ZH NOZZLE SIZE 1.3, .91822 lb, ModelConnection (One-touch/Screw-in) SUPVACEXHZH13D?8/Rc 1 8?10/Rc 1 4?10/Rc 1 4

Lightweight, point-of-use ZH and ZU series vacuum generators combine design simplicity with high performance. Simply plug an air supply tube in one end, and vacuum is ready at the other end. The slim ZU generators are extra compact. The ZH and ZU immediate response may be quicker than central vacuum systems. Also, these generators are often smaller and lighter than the bulky vacuum lines

Poloneza 89, 02-826 Warszawa, Poland Red LED is ON. Non-restorable error is detected. (e.g. Hardware failure) (1) Set the number of occupied I/O points for the module and each parameter of the "remote". PORTUGAL (351) 21 472 45 00 OFF No remote connected. Refer to the LED Display.

Poloneza 89, 02-826 Warszawa, Poland Troubleshooting Green LED is ON. Remote is normal. (1) Set the number of occupied I/O points for the module and each parameter of the "remote". Restorable error is detected. (LED flashes when more than one diagnostic information item is detected.)

The following shows an example of a switching count set point with 50.000.000 cycles according to the transmission method of the upper communication. 50.000.000(dec) = 80 F0 FA 02 (hex) (little endian) 50.000.000(dec) = 02 FA F0 80 (hex) (big endian) -22No.EX-OMY0021 Output number layout / Process data The process data of this product is designed with byte array base data type, so the byte

. -70No.PF-OMO0005-F Dimensions (in mm) PFMB7201-02 PFMB7201-N02 -71No.PF-OMO0005-F PFMB7201-02L PFMB7201-N02L -72No.PF-OMO0005-F PFMB7201S-02 PFMB7201S-N02 -73No.PF-OMO0005-F PFMB7201S-02L PFMB7201S-N02L -74No.PF-OMO0005-F PFMB7201-F02 -75No.PF-OMO0005-F PFMB7201-F02L -76No.PF-OMO0005-F PFMB7201S-F02 -77No.PF-OMO0005-F PFMB7201S-F02L -78No.PF-OMO0005-F PFMB7201-C8 -79No.PF-OMO0005-F PFM7B7201

or less Ionic silica [mg/L] 30 or less 50 or less Iron [mg/L] 0.3 or less 1.0 or less Copper [mg/L] 0.1 or less 0.3 or less Sulfide ion [mg/L] Should not be Should not be Referential detected any detected any item Ammonium ion [mg/L] 0.1 or less 1.0 or less Residual chlorine [mg/L] 0.3 or less 0.3 or less Free carbon dioxide [mg/L] 4.0 or less 4.0 or less Quoted from the standard JRA-GL-02

or less Ionic silica [mg/L] 30 or less 50 or less Iron [mg/L] 0.3 or less 1.0 or less Copper [mg/L] 0.1 or less 0.3 or less Sulfide ion [mg/L] Should not be Should not be Referential detected any detected any item Ammonium ion [mg/L] 0.1 or less 1.0 or less Residual chlorine [mg/L] 0.3 or less 0.3 or less Free carbon dioxide [mg/L] 4.0 or less 4.0 or less Quoted from the standard JRA-GL-02

(including 6 pcs. of M8 bolts) 7 Weight (in the dry state)11 kg Approx.222 Approx.251 Approx.315 HRL Series Documents 8-1 HRX-OM-Y098 Chapter 8 Documents 1 Use fluid for circulating fluid that conforms to: Clean water: Water Quality Standards of the Japan Refrigeration and Air Conditioning Industrial Association (JRA GL-02-1994) 2 (1) Facility water temperature:32C,(2) Circulating fluid:

Silencer Compact resin type Metal body type High noise reduction type Part Part number number AN20-02 AN30-03 AN40-04 AN500-06 AN600-10 AN202-02 AN302-03 AN402-04 ANA1-06 ANA1-10 Piping size 1/4 3/8 1/2 3/4 1 1/4 3/8 1/2 3/4 1 AMA20#-##C-#-#L# NC AMA20#-##D-#-#L# NO AMA30#-##C-#-#L# NC AMA30#-##D-#-#L# NO AMA40#-##C-#-#L# NC AMA40#-##D-#-#L# NO AMA60#-##C-#-#L# NC AMA60#-##D-#-#L# NO -147No.PF-OMA1007

(Coil)(Lead wire) 3 positions, closed center B port used VS4424-02(Coil)(Lead wire) Port size Rc1/4 Voltage AC100,110,200,220,24V(50/60Hz) DC12,24,32,48,100,110V Leads entry Grommet , DIN type terminal Manual override Provided Insulation Equivalent to class B Allowable voltage variation -15% to +10% of rating. 1-2.

The following shows an example of a switching count set point with 50.000.000 cycles according to the transmission method of the upper communication. 50.000.000(dec) = 80 F0 FA 02 (hex) (little endian) 50.000.000(dec) = 02 FA F0 80 (hex) (big endian) Structure of Output Switching Counts State (index 77) The output state for switching counts threshold exceeded of each output (output 0 to output

SFD200-*02 parts list SFD200-C** parts list 1. Description and Function of Each Part A place exposed to excessive humidity and dust. A place exposed to impact and vibration. Cover Resin Thread piping at In and OUT side. Bracket Resin Fixes the housing. O-ring Rubber Seals the element, cover and fitting body.

more (50 VDC by megameter) Between wires and case Temperature characteristic 3% F.S. (25 C Ambient temperature range)) Oil resistant vinyl cabtyre cable 3 cores (N.P) 3.5, 2 m 4 cores (A.B) Sectional area of conductor: 0.15 mm2 (AWG26) 5 cores (R.T.S.V) Outside diameter of insulator: 0.95 mm Lead wire Standard CE marked (EMC directive/RoHS directive), UL/CSA Piping specifications Model No. 02