Lightweight, point-of-use ZH and ZU series vacuum generators combine design simplicity with high performance. Simply plug an air supply tube in one end, and vacuum is ready at the other end. The slim ZU generators are extra compact. The ZH and ZU immediate response may be quicker than central vacuum systems. Also, these generators are often smaller and lighter than the bulky vacuum lines
This is a legacy product. Please contact us for the latest version.sales@ocaire.com, VACUUM EJECTOR, VACUUM SERIES, ZH VACUUM EJECTOR, DC, ZH NOZZLE SIZE 1.3, .91822 lb, ModelConnection (One-touch/Screw-in) SUPVACEXHZH13D?8/Rc 1 8?10/Rc 1 4?10/Rc 1 4
Lightweight, point-of-use ZH and ZU series vacuum generators combine design simplicity with high performance. Simply plug an air supply tube in one end, and vacuum is ready at the other end. The slim ZU generators are extra compact. The ZH and ZU immediate response may be quicker than central vacuum systems. Also, these generators are often smaller and lighter than the bulky vacuum lines
Series VFM is a 5 port, compact, mechanical valve available in a rubber (VFM300) or metal (VFM200) seal style. This series has a large flow capacity (Cv 1.0) and a high cycle rate. The VFM offers an internal or external pilot body option and a variety of actuator choices.Fluid: air, inert gas, Operating pressure range: 0.1 to 1.0MPa, Effective area (Cv): 18mm 2 (1.0), Maximum frequency (
Series VFM is a 5 port, compact, mechanical valve available in a rubber (VFM300) or metal (VFM200) seal style. This series has a large flow capacity (Cv 1.0) and a high cycle rate. The VFM offers an internal or external pilot body option and a variety of actuator choices.Fluid: air, inert gas, Operating pressure range: 0.1 to 1.0MPa, Effective area (Cv): 18mm 2 (1.0), Maximum frequency (
Series VFM is a 5 port, compact, mechanical valve available in a rubber (VFM300) or metal (VFM200) seal style. This series has a large flow capacity (Cv 1.0) and a high cycle rate. The VFM offers an internal or external pilot body option and a variety of actuator choices.Fluid: air, inert gas, Operating pressure range: 0.1 to 1.0MPa, Effective area (Cv): 18mm 2 (1.0), Maximum frequency (
Poloneza 89, 02-826 Warszawa, Poland Red LED is ON. Non-restorable error is detected. (e.g. Hardware failure) (1) Set the number of occupied I/O points for the module and each parameter of the "remote". PORTUGAL (351) 21 472 45 00 OFF No remote connected. Refer to the LED Display.
Poloneza 89, 02-826 Warszawa, Poland Troubleshooting Green LED is ON. Remote is normal. (1) Set the number of occupied I/O points for the module and each parameter of the "remote". Restorable error is detected. (LED flashes when more than one diagnostic information item is detected.)
The following shows an example of a switching count set point with 50.000.000 cycles according to the transmission method of the upper communication. 50.000.000(dec) = 80 F0 FA 02 (hex) (little endian) 50.000.000(dec) = 02 FA F0 80 (hex) (big endian) -22No.EX-OMY0021 Output number layout / Process data The process data of this product is designed with byte array base data type, so the byte
. -70No.PF-OMO0005-F Dimensions (in mm) PFMB7201-02 PFMB7201-N02 -71No.PF-OMO0005-F PFMB7201-02L PFMB7201-N02L -72No.PF-OMO0005-F PFMB7201S-02 PFMB7201S-N02 -73No.PF-OMO0005-F PFMB7201S-02L PFMB7201S-N02L -74No.PF-OMO0005-F PFMB7201-F02 -75No.PF-OMO0005-F PFMB7201-F02L -76No.PF-OMO0005-F PFMB7201S-F02 -77No.PF-OMO0005-F PFMB7201S-F02L -78No.PF-OMO0005-F PFMB7201-C8 -79No.PF-OMO0005-F PFM7B7201
or less Ionic silica [mg/L] 30 or less 50 or less Iron [mg/L] 0.3 or less 1.0 or less Copper [mg/L] 0.1 or less 0.3 or less Sulfide ion [mg/L] Should not be Should not be Referential detected any detected any item Ammonium ion [mg/L] 0.1 or less 1.0 or less Residual chlorine [mg/L] 0.3 or less 0.3 or less Free carbon dioxide [mg/L] 4.0 or less 4.0 or less Quoted from the standard JRA-GL-02
or less Ionic silica [mg/L] 30 or less 50 or less Iron [mg/L] 0.3 or less 1.0 or less Copper [mg/L] 0.1 or less 0.3 or less Sulfide ion [mg/L] Should not be Should not be Referential detected any detected any item Ammonium ion [mg/L] 0.1 or less 1.0 or less Residual chlorine [mg/L] 0.3 or less 0.3 or less Free carbon dioxide [mg/L] 4.0 or less 4.0 or less Quoted from the standard JRA-GL-02
(including 6 pcs. of M8 bolts) 7 Weight (in the dry state)11 kg Approx.222 Approx.251 Approx.315 HRL Series Documents 8-1 HRX-OM-Y098 Chapter 8 Documents 1 Use fluid for circulating fluid that conforms to: Clean water: Water Quality Standards of the Japan Refrigeration and Air Conditioning Industrial Association (JRA GL-02-1994) 2 (1) Facility water temperature:32C,(2) Circulating fluid:
Silencer Compact resin type Metal body type High noise reduction type Part Part number number AN20-02 AN30-03 AN40-04 AN500-06 AN600-10 AN202-02 AN302-03 AN402-04 ANA1-06 ANA1-10 Piping size 1/4 3/8 1/2 3/4 1 1/4 3/8 1/2 3/4 1 AMA20#-##C-#-#L# NC AMA20#-##D-#-#L# NO AMA30#-##C-#-#L# NC AMA30#-##D-#-#L# NO AMA40#-##C-#-#L# NC AMA40#-##D-#-#L# NO AMA60#-##C-#-#L# NC AMA60#-##D-#-#L# NO -147No.PF-OMA1007
(Coil)(Lead wire) 3 positions, closed center B port used VS4424-02(Coil)(Lead wire) Port size Rc1/4 Voltage AC100,110,200,220,24V(50/60Hz) DC12,24,32,48,100,110V Leads entry Grommet , DIN type terminal Manual override Provided Insulation Equivalent to class B Allowable voltage variation -15% to +10% of rating. 1-2.
The following shows an example of a switching count set point with 50.000.000 cycles according to the transmission method of the upper communication. 50.000.000(dec) = 80 F0 FA 02 (hex) (little endian) 50.000.000(dec) = 02 FA F0 80 (hex) (big endian) Structure of Output Switching Counts State (index 77) The output state for switching counts threshold exceeded of each output (output 0 to output
SFD200-*02 parts list SFD200-C** parts list 1. Description and Function of Each Part A place exposed to excessive humidity and dust. A place exposed to impact and vibration. Cover Resin Thread piping at In and OUT side. Bracket Resin Fixes the housing. O-ring Rubber Seals the element, cover and fitting body.
more (50 VDC by megameter) Between wires and case Temperature characteristic 3% F.S. (25 C Ambient temperature range)) Oil resistant vinyl cabtyre cable 3 cores (N.P) 3.5, 2 m 4 cores (A.B) Sectional area of conductor: 0.15 mm2 (AWG26) 5 cores (R.T.S.V) Outside diameter of insulator: 0.95 mm Lead wire Standard CE marked (EMC directive/RoHS directive), UL/CSA Piping specifications Model No. 02
Width across torque (Nm) flats AS1002F-02 0.07 4.5 Installation AS1002F 0.2 7 AS2002F 0.3 9 Warning AS2052F 1 12 (1) Operation Manual AS3002F 2 14 Install and operate only after reading the operation manual carefully and understanding the contents. Keep the manual where is can be referred to if necessary.
Description Materials Bonnet Aluminum die-cast Nozzle diaphragm assembly Aluminum, Weather resistant NBR Seal HNBR Seal NBR Diaphragm spacer Polyacetal Supply diaphragm Weather resistant NBR Exhaust diaphragm assembly Aluminum, Weather resistant NBR Valve assembly Aluminum, stainless steel, HNBR Body Aluminum die-cast Grease: lithium grease -8- How to order IR 0 0 02 0 2 BG A