Select an air filter with a filtration size of 5m or smaller. 3. Take measures to ensure air quality, such as by installing an aftercooler, air dryer, or water separator. Compressed air that contains a large amount of moisture can cause malfunction of pneumatic equipment such as rotary tables.

Select an air filter with a filtration size of 5m or smaller. Take measures to ensure air quality, such as by installing an aftercooler, air dryer, or water separator. Compressed air that contains a large amount of moisture can cause malfunction of pneumatic equipment such as rotary tables.

If the cable length exceeds 5m, the speed/pushing force will be reduced 10% per 5m as the maximum. ( if cable length is 15m: 20% reduction as the maximum. ) [Transportation] Caution 1. Do not carry or swing the product by the cables. 34 - 5. Electric actuators / Common precautions 5.1 Design and selection Warning 1.

If the cable length exceeds 5m, the speed/thrust will decrease by up to 10% for every 5m. (For 15m: Max. 20% reduction) Note 5"Pushing speed is the allowable speed for the pushing operation. When transporting and pushing a workpiece, operate the actuator with the "vertical load capacity" or less. Note 6This is a reference value for correcting errors in reciprocating motion.

Furthemore, if the cable length exceeds 5m then it will decrease by up to 10% for each 5m.(At 15m : Reduced by up to 20%) * 4 A reference value for correcting an error in reciprocal operation. * 5 Impact resistance: No malfunction occurred when the actuator was tested with a drop tester in both an axial direction and a perpendicular direction to the lead screw.

If the cable length exceeds 5m, the speed / pushing force will be reduced 10% per 5m as the maximum. (If cable length is 15m: 20% reduction as the maximum. ) [Transportation] ! Caution 1. Do not carry or swing the product by the motor or the cable. 118 - 8. Electric actuators/Common precautions 8.1 Design and selection ! Warning 1.

. / A 50mm ( ) 5m 5m 10% 15m 20% 109 - 8. / 8.1 () EMG / 110 - 1000 1 / UL,UL1310Class2 8.2 111 - 8.3 DC24VSVON a) b) c) d) e) D 100 112 - 8.4 1. 2. 3. 4. 5. 6. 7. 8. -106090% -106090 113 - 8.5 5 P5 8.6 SVRE OFF [BK RLS]DC24V [BK RLS] [BK RLS] DC24V [BK RLS] EMG /LEC 114 - 9. 9.1 / 9.2 ON 115 - 5 () 116 - 9.3 50mm 9.4 ( ) 117 - 9.5 9.6 D 100 9.7 118 - 10. No.

NPN type N (Enter from the electric actuator part number LE to PNP type P stroke / rotating angle) I/O cable length Option None Nil Screw mounting Nil 1.5m 1 DIN rail mounting D 3m 3 5m 5 Caution Products are shipped after setting the electric actuator specification parameters. Confirm the combination of the controller and the electric actuator is correct.

If the cable length exceeds 5m, the speed / pushing force will be reduced by a maximum of 10% per 5m. (If cable length is 15m: Maximum 20% reduction.) [Transportation] Caution 1. Do not carry or swing the product by the motor or the cable 48 - 15. Electric actuators/Common precautions 15.1 Design and selection Warning 1. Be sure to read the Operation Manual.

If the cable length exceeds 5m, the speed / pushing force will be reduced by a maximum of 10% per 5m. (If cable length is 15m: Maximum 20% reduction.) [Transportation] Caution 1. Do not carry or swing the product by the motor or cable 33 - 6. Electric actuators / Common precautions 6.1 Design and selection Warning 1.

F7NWV F9NWV F9NW Relay PLC 3 wire (NPN) 24V Yes F79W Diagnosis indicator (2 color) 5V, 12V IC F7PW 3 wire (PNP) F9PWV F9PW 12V F9BWV F9BW F7BWV J79W Grommet 2 wire F9BA F7BA Water resistant (2 color) F7NT With timer 3 wire (NPN) 5V, 12V IC F79F With diagnosis output (2 color) 4 wire (NPN) Latch with diagnosis output (2 color) F7LF Note 1) Symbols for wire length 0.5m 3m L 5m

When 40m is required: 1-40 If indicating "7" only, the filtration rate is 5m. Optional filtration rate is required, indicate like 17-l. Ex.) When requiring "stainless steel and 40 m"; 17-40 1 Note 1) When specifying more than one number, indicate them in numerical order.

Lead wire length indication (Example) D-F9P L 2-wire 3-wire New Old New Old Lead wire length Power supply + Brown Red Brown Output (+) Red Nil L Z 0.5m 3m 5m Blue Black Output () Power supply GND Blue Black Output White Black Solid state with diagnostic output Solid state with latch type diagnostic output Note 1) Lead wire length Z: 5m applicable auto switch Solid state switch: All models

D-F7lWV, Z(5m) is not available. F7BA and F9BA is applicable to oil-proof auto switch (-X5).

Indication of lead wire length (Example) D-F9P L 2 wire 3 wire New New Old Old Lead wire length Brown Brown Output (+) Red Power supply (+) Red Nil L Z 0.5m 3m 5m Blue Blue Black Power supply GND Black Output () Output White Black Note 1) Lead wire length Z: Auto switch with 5m length Solid state: All models produced upon receipt of order (standard procedure).

Lead wire length indication (Example) D-F9P 2-wire 3-wire L Old New Old New Red Brown Output (+) Power supply + Red Brown Lead wire length Nil L Z Output () Black Blue Power supply GND Black Blue 0.5m 3m 5m Output White Black Solid state with diagnostic output Solid state with latch type diagnostic output New New Old Old Note 1) Lead wire length Z: Auto switch applicable to 5m length Solid

MK-F063 Relay PLC 24V 3 wire (PNP) Boss mounting ring Set pin Bolt for cylinder body F9PWV F9BWV F9PW F9BW J79W F7BWV 12V 2 wire Water resistant (2 color) F7BA F9BA F7NT 3 wire (NPN) With timer Diagnostic output (2 color) Grommet 5V, 12V F79F IC 4 wire (NPN) Latching with diagnostic output (2 color) F7LF Strong magnetic field resistant (2 color) P5DW** 2 wire * Lead wire 0.5m (Example) A80C 5m

Size: 32, Motor Mounting Position: Top Mounting, Lead: B (Size 16: 5mm, Size 25: 6mm, Size 32/40: 8mm), Stroke: 500mm, Motor Option: C (w/Motor Cover), Rod End Thread: Rod End Female Thread, Mounting: Ends Tapped/Body Bottom Tapped, Top Mounting & In-line, Actuator Cable Type, Length: R5 (5m), Controller: C61 [Parallel Input (PNP)], Mounting: 8 (DIN Rail), I/O Cable: 5 (I/O Cable, 5m)

), Controller Type - LEC, JXC: 1P (LECP1, PNP, Programless Type), I/O Cable Length for LEC: 5 (5m), Controller Mounting: D (DIN Rail)

Cable Length for LEC: Without Cable, Controller Mounting: 7 (Screw Mounting), Communication Plug Connector or I/O Cable Length for JXC: 5 (5m)