or less 0.05 Nm or less 0.10 Nm or less 0.20 Nm or less Allowable rotation speed 3000 min-1 (r.p.m.)Note 3) 2000 min-1 (r.p.m.) 1500 min-1 (r.p.m.) 900 min-1 (r.p.m.) 600 min-1 (r.p.m.)
Add/dEC OUT1 (29 ) OUT1 OUT1 ( [n2dH]) ( [n2AH]) 3 1 3 6 6 1 6 3 1 1 4. [F 2] OUT2 -37No.PF-OMN0011CN-C d. ([ tP]) 4. [F 2] OUT2 e. ([ tPL]) [ tPH] or [ tnH] ([ tPH]) 4.
Flow Rate and Effective Area AS1001F AS2001F AS3001F AS2051F AS4001F Model 3.2, 4, 6 4 6 6 8 6 8 10, 12 10 12 Metric size Tubing O.D. 1/8" 5/32" 3/16", 1/4" 3/16" 1/4" 1/4" 5/16" 3/16" Inch size 1/4" 5/16" 3/8" 3/8" 1/2" 5/32" Flow rate (l/min(ANR) 290 460 230 100 130 420 660 920 1050 1390 Controlled flow (Free flow) 4.5 7 3.5 1.5 2 6.5 10 14 16 21 Effective area (mm2) Note) Flow rate values
Flow Rate and Effective Area AS1001F AS2001F AS3001F AS2051F AS4001F Model 3.2, 4, 6 4 6 6 8 6 8 10, 12 10 12 Metric size Tubing O.D. 1/8" 5/32" 3/16", 1/4" 3/16" 1/4" 1/4" 5/16" 3/16" Inch size 1/4" 5/16" 3/8" 3/8" 1/2" 5/32" Flow rate (l/min(ANR) 290 460 230 100 130 420 660 920 1050 1390 Controlled flow (Free flow) 4.5 7 3.5 1.5 2 6.5 10 14 16 21 Effective area (mm2) Note) Flow rate values
AMX-OMU0058-C PRODUCT NAME Air preparation filter MODEL / Series / Product Number Main Line Filter AFF70D, AFF80D, AFF90D Mist Separator AM70D, AM80D, AM90D Micro Mist Separator AMD70D, AMD80D, AMD90D -1- Doc. no. AMX-OMU0058-C Contents Page Safety Instructions 3 1. Be sure to read before use. 1-1. Handling Precautions 5 1-2. Installation/Piping 8 1-3. Maintenance 10 2.
Tubing size Tensile force of tubing (N) 3.2, 1/8'' 5 4, 5/32'' 8 6, 1/4'' 12 8, 5/16'' 20 10, 3/8'' 30 12, 1/2'' 35 16 50 7 - Caution (1) Chamfer dimension for female thread of the connection thread Confirming to ISO 16030 (air pressure fluid dynamics connection ports and stud ends), the chamfer dimensions shown below are recommended.
Confirm the total of x, y and z is 1 or less. x + y + z 1 When 1 is exceeded, please consider a reduction of acceleration and work load, or a change of the work load center position and series. Acceleration [mm/s2]: a Work load [kg]: m Work load center position [mm]: Xc/Yc/Zc z y 1. Horizontal 3. Wall LEF x y LEJ LEJ x z LEL x 2. Bottom 4. Vertical LEM z y x y z LEY Example LES 1.
How to use DIN connector Indicator Light/Surge Voltage Suppressor Disassembly 1) Loosen screw (1) and pull up housing (2) in the direction of screw (1) to remove the connector from the body (solenoid). 2) Pull out screw (1) from housing (2). 3) On the bottom part of terminal block (3), there is a notch (9).
Please consult with SMC, as there are some standard valve products that use fluorine grease for food processing equipment (NSF H-1). (1) Normally, fittings with a sealant can be reused up to 2 to 3 times. (2) To prevent air leakage through the sealant, remove any loose sealant stuck to the fitting by blowing air over the threaded portion. (3) If the sealant no longer provides effective sealing
Parts description of the air gripper . 5 3. Product Specifications . 6 3-1. How to order . 6 3-2. Specifications . 6 3-3. Auto switch . 7 3-4. Gripping force . 8 3-5. Gripping point . 9 3-6. Dimensions . 10 3-7. Air Gripper . 11 3-8. Center of gravity . 12 4. Product Specifications . 13 4-1. Attachment . 13 4-3. Mounting to NEXTAGE . 15 4-4. Piping . 16 4-5. Speed controller . 16 4-6.
60 2-1/2 NPT 174 R134a 680 3 1/2 PDE180-S 654 5.7 6.2 23.6 78.7 55.1 19.7 19.7 460/3/60 2-1/2 NPT 174 R134a 790 3 1/2 PDE200-S 742 6.2 7.0 23.6 78.7 55.1 19.7 19.7 460/3/60 FLANGE 3 150 174 R134a 890 3 3/4 PDE260-S 1007 7.5 8.5 23.6 78.7 55.1 19.7 19.7 460/3/60 FLANGE 3 150 174 R134a 990 5 PDE310-S 1200 7.8 8.8 23.6 78.7 55.1 19.7 19.7 460/3/60 FLANGE 3 150 174 R134a 1060 5 PDE410-S 1483
Table 15 Parts where grease is to be applied Application of grease Grease Body (inner sliding surface) Piston(Seal groove) Slider(Sliding surface) GR-S-010 Piston seal Tube gasket 23 24 25 O-ring 5 11 1 16 12 7 23 24 12 11 4 25 4 24 25 23 -34- (2) Mount the tube gasket 11 to the left cover 3 to mount to the body 1 . (3) Insert the rack 16 and the piston 4 into the body 1 .
Countermeasure (1) Ensure proper supply pressure and pilot pressure (2) Stop the equipment which is using the air. Locate the source of any air leaks and repair them. (3) Pressurize port 2 (A) and exhaust air from port 3 (R). (It is possible to blow the poppet valve.) (4) Replace the valve. (5) Open the 3 (R) port. (6) Supply air to port 2 (A).
L Stroke+214 26 10 10 (92) 14 2-M5 x 0.8 Effective screw length 10 61 60 57 31 12 6 Reference plane 63.5 62.5 3 3 130 4-M5 x 0.8depth10 F-M5 x 0.8depth10 3-4H10depth5 4-6.5 20 20 12.5 C 31 63.5 13.5 E-100 4H10depth5 5 (26) (44) 110 100 Stroke69 (Stroke+131) 10 92 85 (For 100 to 150 strokes) 208 (For 200 to 1000 strokes) C section detail (S=2/1) 12 3 500 12 3 450 10 2 400 10 2 350 8 1 300
Caution A (-) : Black COM (+): Red B (-) : White(Without lead wire case of single solenoid) 1. Tube attachment/detachment for one-touch fittings 1) Attaching of tubing (1) Take a tube having no flaws on its periphery and cut it off at a right angle. When cutting the tube, use tube cutters TK-1, 2 or 3. Do not use pinchers, nippers or scissors, etc.
,1 1 4 3 8 1 2 3 4 3 8 3 4 Highly resistant to dust and corrosion, operates reliably, and a bowl guard is provided as standard equipment.
Effective area at supply side (mm2) PA 44 38 32 4 2 (A)(B) 4 2 (A)(B) Single Double S at P1=0.7MPa/P2=0.5MPa PB 38 40 31 Number of pilots Effective area at exhaust side (mm2) AEA 5 1 3 (EA)(P)(EB) 5 1 3 (EA)(P)(EB) 90 4 2 (A)(B) 4 2 (A)(B) 77 S at P2=0.5MPa BEB 5 1 3 (EA)(P)(EB) 5 1 3 (EA)(P)(EB) How to Exchange Air Operated Valves Loosen set screw and take air operated valve out vertically
T3 Cylinder with Bypass Piping Component Parts T1 81.4 93.3 99.8 T2 63.4 73.8 80.3 T3 57.8 67.8 74.3 TH 47.9 57.3 57.3 TP Rc, NPT, G 1/8 Rc, NPT, G 1/4 Rc, NPT, G 1/4 Description No. 1 2 3 4 Qty. 1 1 1 1 Part no.
Tubing size Tensile force of tubing (N) 3.2, 1/8'' 5 4, 5/32'' 8 6, 1/4'' 12 8, 5/16'' 20 10, 3/8'' 30 12, 1/2'' 35 16 50 7 - Caution (1) Chamfer dimension for female thread of the connection thread Confirming to ISO 16030 (air pressure fluid dynamics connection ports and stud ends), the chamfer dimensions shown below are recommended.
AC 110 12 2 12 3 q e w e t y 220 10 1 10 1.5 440 6 1 3 1 550 5 0.8 2 0.5 r b contact w a contact r q DC 24 3 2.5 3 2.5 C C 48 1.5 1.2 1.5 1.25 When rising pressure q w = ON e r = OFF When rising pressure q e r y = ON q w r t = OFF 110 0.5 0.25 0.5 0.2 220 0.25 0.1 0.25 0.1 Insulation resistance: 100 M or more at 500 VDC by megameter Voltage resistance: 2000 VAC/1 min. 16-9-5 Series