An example is shown below. direction + direction direction + direction 0 5 10 [mm] 0 5 10 [mm] This example shows the Target Position set at 10 mm. The table of the Card Motor moves to 10 mm from the origin position. 11.5 Relative positioning The Target Position is determined based on the current position.

Fig. 9-4 Cooling capacity(HRS030--20-(BJMT)) 9.5 Heating capacity 9.5.1 HRS030-A-20-(BJMT) 1000 1000 Ambient Ambient temperatur temperatur 800 e e Heating capacityW 800 Heating capacityW 40 32 25 20 5 40 32 25 20 5 600 600 400 400 200 200 0 0 5 10 15 20 25 30 35 40 5 10 15 20 25 30 35 40 Circulating fluid temperature Circulating fluid temperature 50Hz 60Hz Fig. 9-5 Heating capacity(HRS030

Standard Stroke Maximum manufacturable stroke (mm) Bore size (mm) Standard stroke (mm) 10 50, 100, 150, 200, 250, 300 500 15 50, 100, 150, 200, 250, 300, 350, 400, 450, 500 750 25 100, 150, 200, 250, 300, 350, 400, 450, 500, 550, 600 1200 The stroke is available in 1 mm increments with the maximum stroke as the upper limit.

10 5 5 0 0 5 10 15 20 25 30 35 5 10 15 20 25 30 35 Circulating fluid temperature [] Circulating fluid temperature [] 60Hz 50Hz Fig. 8-3: Cooling Capacity 8.5 Pump Capacity 0.6 60 Usable flow rate range 0.5 50 Circulating fluid outlet (60Hz) Lifting head [m] Pressure [MPa] 0.4 40 0.3 30 0.2 20 Circulating fluid outlet (50Hz) 0.1 10 Circulating fluid return 0.0 0 0 10 20 30 40 50 60 70 80

Symbol O.D. thread size Stroke 0805 1006 1410 8 mm 5 mm 2 pcs. 1 pc. 10 mm 6 mm 3 pcs. 1 pc. 14 mm 10 mm 1 pc.

10 10 MGF40 Data MGF40 10 5 4 3 5 4 3 2 2 5 5 1 10 20 30 40 50 100 200 300 400 1 5 4 10 20 30 40 50 100 200 300 400 5 10 50 100 10 50 100 Eccentric distance l (mm) Eccentric distance l (mm) Stroke (mm) Stroke (mm) l = 200 mm l = 300 mm Graph (3) Graph (4) v = 150 mm/s or less v = 200 mm/s or less Graph (7) Graph (8) 20 300 300 200 200 MGF100 MGF100 20 100 100 MGF100 MGF100 10 MGF100 MGF100

Model CYP15 CYP32 Series Throttle valve 10-AS2200-01-X214 Elbow type 10-AS1200-M5-X216 Metal body piping type 10-AS2000-01-X209 In-line type 10-AS1000-M5-X214 10-AS2201F-01-04-X214 10-AS1201F-M5-04-X214 Elbow type (throttle valve) 10-AS2201F-01-06-X214 10-AS1201F-M5-06-X214 10-AS2201F-01-06-X214 Operation 10-AS2301F-01-04-X214 10-AS1301F-M5-04-X214 Resin body with One-touch fitting Caution

(Example) SS3YJA7-41-03-01. 1 set SYJA714 . 2 sets SYJ700-10-2A . 1 set (Example) SS3YJA5-40-03-01. 1 set SYJA514 . 2 sets SYJ500-10-3A . 1 set The asterisk denotes the symbol for assembly.

weight m (kg) Load weight m (kg) 30 30 MGF63 10 20 20 MGF63 5 10 10 MGF40 5 4 3 5 4 3 MGF40 MGF40 5 MGF40 2 2 3 5 2 1 1 10 20 30 40 50 100 200 300 400 10 20 30 40 50 100 200 300 400 10 50 100 5 10 50 100 Eccentric distance l (mm) Eccentric distance l (mm) Stroke (mm) Stroke (mm) How to read the graph 1) When the load weight is 70kg, eccentric distance is 60mm, and the maximum speed is 150mm

weight m (kg) Load weight m (kg) 30 30 MGF63 10 20 20 MGF63 5 10 10 MGF40 5 4 3 5 4 3 MGF40 MGF40 5 MGF40 2 2 3 5 2 1 1 10 20 30 40 50 100 200 300 400 10 20 30 40 50 100 200 300 400 10 50 100 5 10 50 100 Eccentric distance l (mm) Eccentric distance l (mm) Stroke (mm) Stroke (mm) How to read the graph 1) When the load weight is 70kg, eccentric distance is 60mm, and the maximum speed is 150mm

0.5MPa 0.5MPa Gripping force N Gripping force N 0.4MPa 0.4MPa 150 150 F 0.3MPa 0.3MPa 100 100 0.2MPa 0.2MPa 50 50 0.1MPa 0.1MPa 0 0 10 10 20 20 30 30 40 40 50 50 Gripping point L mm Gripping point L mm MHS2-50D MHS2-50D F 400 400 Internal gripping Pressure 0.6MPa Pressure 0.6MPa 300 300 Gripping force N 0.5MPa 0.5MPa Gripping force N 0.4MPa 0.4MPa 200 200 0.3MPa 0.3MPa 1N: Approx. 0.102kgf

For a 10 orifice (VXS23/Port size 1/4), P 0.05 MPa The optimum size for a pressure differential of P 0.2 MPa and a flow of 50 L/min will be the VXS23 (10 orifice, port size 3/8). 500 400 VXS26 25 Cv = 12 300 VXS25 20 Cv = 9.2 200 VXS24 15 Cv = 5.3 Flow rate Q [L/min] 100 VXS23 Port size 3/8 10 Cv = 2.8 VXS23 Port size 1/4 10 Cv = 2.4 50 40 30 25 20 10 0.01 0.02 0.03 0.04 0.05 0.1 0.2 0.3

temperature [C] 0 0 10 20 30 40 50 60 70 Circulating fluid temperature [C] For the high-pressure pump (Option), the heating capacity increases by approx. 10 W.

VY1 How to Order G Port size (IN, OUT) PPA 1/8 (Male thread), M5 x 0.8 (Female thread) 1/8 (Female thread) IN OUT 01 AL ARJ 3 10 01 BG ARJ 3 10 F BG With One-touch fitting 04 01 Option Body size 0.7 MPa setting (Standard) 0.2 MPa setting (1) Nil 1 S Model With seal Relieving type 10 Note 1) Compared with standard specifications, its adjusting spring has been only changed for 0.2 MPa.

Model XT13-394-06 XT13-394-10 INA-48-1-06 INA-48-1-10 INA-48-16-10 INA-48-16-06 INA-48-58-10-H INA-48-58-06-H Port size Rc3/4 Rc1 Rc3/4 Rc1 Rc3/4 Rc1 Rc3/4 Rc1 Relief mechanism Non-relief Relief Non-relief Fluid Deionized water (Pure water) Air, N2 Proof pressure 1.9 MPa 1.5 MPa Max. operating pressure 1.3 MPa 1.0 MPa Set pressure 0.1 to 1.0 MPa 0.05 to 0.5 MPa 5 to 60C Ambient and fluid

30 40 V15 V3 L 1 H V2 2 4 10 30 40 -30 in.Hg to 15 psig -30 in.Hg to 30 psig -30 in.Hg to 60 psig -30 in.Hg to 100 psig -30 in.Hg to 160 psig -30 in.Hg to 200 psig 0 to 200 psig 0 to 400 psig 0 to 1000 psig 0 to 3000 psig 0 to 4000 psig -0.1 to 0.1 MPa -0.1 to 0.2 MPa -0.1 to 0.4 MPa -0.1 to 0.7 MPa -0.1 to 1.1 MPa -0.1 to 1.4 MPa 0 to 1.5 MPa 0 to 3 MPa 0 to 7 MPa 0 to 21 MPa 0 to 28 MPa

DA N4odels wi function at 10%oitheir maximum rated enerS/ percyce.lilessthan 10%, a snia ler modelshoud bespecned. 2. Prov de a positile stop 3nm before end of stroke in tension and cgr.pression to prevent nternal bottoming. 3.

LJ1H202NC 14 56 to 740 to 930 to 600 to 500 to 1000 LJ1H303PD to 1000 to 1000 to 700 to 500 18 60 to 1000 126 114 108 LJ1H303ND 20 62 to 1000 to 1000 to 700 to 500 to 1000 LJ1H102PH-K 24 66 to 400 104 110 LJ1H102NH-K 28 70 to 400 LJ1H202PA-K 34 76 to 500 106 112 LJ1H202NA-K 38 80 to 500 LJ1H102PB-K 26 68 to 600 145 104 110 LJ1H102NB-K 30 72 to 600 LJ1H202PF-K 32 74 to 250 106 112 LJ1H202NF-K

600 800 1000 1000 2000 0 0 0 Flow rate (l/min)(ANR) Flow rate (l/min)(ANR) Flow rate (l/min)(ANR) VH600 Effective area S=194mm2 Supply pressure MPa 0.7 0.7 Valve output pressure (MPa) 0.6 0.6 0.5 0.5 0.4 0.4 0.2 0.3 0.3 0.2 0.1 0.1 10 15 0 5 Flow rate (l/min)(ANR) 3.6-7 Hand Valve Series VH Construction VH200 5 6 4 3 1 SlA 7 VlA 8 1 (P) SlA 4 (B) 2 (A) 2 3 (R) VlA VH300 / 400 5 6 VM/VR 4